These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 30714915)

  • 21. A systematic 3-D magnetic particle imaging simulation model for quantitative analysis of reconstruction image quality.
    Shen Y; Zhang L; Hui H; Guo L; Wang T; Yang G; Tian J
    Comput Methods Programs Biomed; 2024 Jul; 252():108250. PubMed ID: 38815547
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Characterization of magnetic nanoparticle systems with respect to their magnetic particle imaging performance.
    Ludwig F; Eberbeck D; Löwa N; Steinhoff U; Wawrzik T; Schilling M; Trahms L
    Biomed Tech (Berl); 2013 Dec; 58(6):535-45. PubMed ID: 23751379
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Hybrid system calibration for multidimensional magnetic particle imaging.
    von Gladiss A; Graeser M; Szwargulski P; Knopp T; Buzug TM
    Phys Med Biol; 2017 May; 62(9):3392-3406. PubMed ID: 28378709
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Enhanced reconstruction in magnetic particle imaging by whitening and randomized SVD approximation.
    Kluth T; Jin B
    Phys Med Biol; 2019 Jun; 64(12):125026. PubMed ID: 30995635
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Discriminating nanoparticle core size using multi-contrast MPI.
    Shasha C; Teeman E; Krishnan KM; Szwargulski P; Knopp T; Möddel M
    Phys Med Biol; 2019 Mar; 64(7):074001. PubMed ID: 30870817
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Multi-color magnetic nanoparticle imaging using magnetorelaxometry.
    Coene A; Leliaert J; Liebl M; Löwa N; Steinhoff U; Crevecoeur G; Dupré L; Wiekhorst F
    Phys Med Biol; 2017 Apr; 62(8):3139-3157. PubMed ID: 28165335
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Model-based reconstruction for magnetic particle imaging.
    Knopp T; Sattel TF; Biederer S; Rahmer J; Weizenecker J; Gleich B; Borgert J; Buzug TM
    IEEE Trans Med Imaging; 2010 Jan; 29(1):12-8. PubMed ID: 19435678
    [TBL] [Abstract][Full Text] [Related]  

  • 28. In vivo liver visualizations with magnetic particle imaging based on the calibration measurement approach.
    Dieckhoff J; Kaul MG; Mummert T; Jung C; Salamon J; Adam G; Knopp T; Ludwig F; Balceris C; Ittrich H
    Phys Med Biol; 2017 May; 62(9):3470-3482. PubMed ID: 28035904
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Electronic field free line rotation and relaxation deconvolution in magnetic particle imaging.
    Bente K; Weber M; Graeser M; Sattel TF; Erbe M; Buzug TM
    IEEE Trans Med Imaging; 2015 Feb; 34(2):644-51. PubMed ID: 25350924
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effect of echo spacing and readout bandwidth on basic performances of EPI-fMRI acquisition sequences implemented on two 1.5 T MR scanner systems.
    Giannelli M; Diciotti S; Tessa C; Mascalchi M
    Med Phys; 2010 Jan; 37(1):303-10. PubMed ID: 20175493
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Analysis of a 3-D system function measured for magnetic particle imaging.
    Rahmer J; Weizenecker J; Gleich B; Borgert J
    IEEE Trans Med Imaging; 2012 Jun; 31(6):1289-99. PubMed ID: 22361663
    [TBL] [Abstract][Full Text] [Related]  

  • 32. First in vivo traveling wave magnetic particle imaging of a beating mouse heart.
    Vogel P; Rückert MA; Klauer P; Kullmann WH; Jakob PM; Behr VC
    Phys Med Biol; 2016 Sep; 61(18):6620-6634. PubMed ID: 27541258
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A wavelet-based sparse row-action method for image reconstruction in magnetic particle imaging.
    Lieb F; Knopp T
    Med Phys; 2021 Jul; 48(7):3893-3903. PubMed ID: 33982810
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Bimodal intravascular volumetric imaging combining OCT and MPI.
    Latus S; Griese F; Schlüter M; Otte C; Möddel M; Graeser M; Saathoff T; Knopp T; Schlaefer A
    Med Phys; 2019 Mar; 46(3):1371-1383. PubMed ID: 30657597
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Gaussian process classification of superparamagnetic relaxometry data: Phantom study.
    Sovizi J; Mathieu KB; Thrower SL; Stefan W; Hazle JD; Fuentes D
    Artif Intell Med; 2017 Oct; 82():47-59. PubMed ID: 28911905
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Pseudo-Polar Fourier Transform-Based Compressed Sensing MRI.
    Yang Y; Liu F; Li M; Jin J; Weber E; Liu Q; Crozier S
    IEEE Trans Biomed Eng; 2017 Apr; 64(4):816-825. PubMed ID: 27305666
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The X-space formulation of the magnetic particle imaging process: 1-D signal, resolution, bandwidth, SNR, SAR, and magnetostimulation.
    Goodwill PW; Conolly SM
    IEEE Trans Med Imaging; 2010 Nov; 29(11):1851-9. PubMed ID: 20529726
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Accelerated magnetic resonance imaging using the sparsity of multi-channel coil images.
    Xie G; Song Y; Shi C; Feng X; Zheng H; Weng D; Qiu B; Liu X
    Magn Reson Imaging; 2014 Feb; 32(2):175-83. PubMed ID: 24268132
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Quantitative model selection for enhanced magnetic nanoparticle imaging in magnetorelaxometry.
    Coene A; Leliaert J; Dupré L; Crevecoeur G
    Med Phys; 2015 Dec; 42(12):6853-62. PubMed ID: 26632042
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Magnetic particle imaging: introduction to imaging and hardware realization.
    Buzug TM; Bringout G; Erbe M; Gräfe K; Graeser M; Grüttner M; Halkola A; Sattel TF; Tenner W; Wojtczyk H; Haegele J; Vogt FM; Barkhausen J; Lüdtke-Buzug K
    Z Med Phys; 2012 Dec; 22(4):323-34. PubMed ID: 22909418
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.