These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

195 related articles for article (PubMed ID: 30721678)

  • 21. Recent Advances in Resting-State Electroencephalography Biomarkers for Autism Spectrum Disorder-A Review of Methodological and Clinical Challenges.
    Heunis TM; Aldrich C; de Vries PJ
    Pediatr Neurol; 2016 Aug; 61():28-37. PubMed ID: 27255413
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The Dry Revolution: Evaluation of Three Different EEG Dry Electrode Types in Terms of Signal Spectral Features, Mental States Classification and Usability.
    Di Flumeri G; Aricò P; Borghini G; Sciaraffa N; Di Florio A; Babiloni F
    Sensors (Basel); 2019 Mar; 19(6):. PubMed ID: 30893791
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Visual Evoked Potential Recordings in Mice Using a Dry Non-invasive Multi-channel Scalp EEG Sensor.
    Yeon C; Kim D; Kim K; Chung E
    J Vis Exp; 2018 Jan; (131):. PubMed ID: 29364268
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Validation of a wireless dry electrode system for electroencephalography.
    Wyckoff SN; Sherlin LH; Ford NL; Dalke D
    J Neuroeng Rehabil; 2015 Oct; 12():95. PubMed ID: 26520574
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Joint Maximum Likelihood Time Delay Estimation of Unknown Event-Related Potential Signals for EEG Sensor Signal Quality Enhancement.
    Kim K; Lim SH; Lee J; Kang WS; Moon C; Choi JW
    Sensors (Basel); 2016 Jun; 16(6):. PubMed ID: 27322267
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Single trial classification of motor imagination using 6 dry EEG electrodes.
    Popescu F; Fazli S; Badower Y; Blankertz B; Müller KR
    PLoS One; 2007 Jul; 2(7):e637. PubMed ID: 17653264
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Magnetoencephalography, a new function diagnostic method].
    Vieth J
    EEG EMG Z Elektroenzephalogr Elektromyogr Verwandte Geb; 1984 Jun; 15(2):111-8. PubMed ID: 6088213
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Pharmaco-EEG Studies in Animals: A History-Based Introduction to Contemporary Translational Applications.
    Drinkenburg WH; Ahnaou A; Ruigt GS
    Neuropsychobiology; 2015; 72(3-4):139-50. PubMed ID: 26901675
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A high-speed brain-computer interface (BCI) using dry EEG electrodes.
    Spüler M
    PLoS One; 2017; 12(2):e0172400. PubMed ID: 28225794
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Neuronal currents and EEG-MEG fields.
    Dassios G
    Math Med Biol; 2008 Jun; 25(2):133-9. PubMed ID: 18413352
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Anatomical constraints on source models for high-resolution EEG and MEG derived from MRI.
    Srinivasan R
    Technol Cancer Res Treat; 2006 Aug; 5(4):389-99. PubMed ID: 16866569
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Full-band EEG (fbEEG): a new standard for clinical electroencephalography.
    Vanhatalo S; Voipio J; Kaila K
    Clin EEG Neurosci; 2005 Oct; 36(4):311-7. PubMed ID: 16296449
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Electrodes.
    Morris HH; Lüders H
    Electroencephalogr Clin Neurophysiol Suppl; 1985; 37():3-26. PubMed ID: 3859406
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The standardized EEG electrode array of the IFCN.
    Seeck M; Koessler L; Bast T; Leijten F; Michel C; Baumgartner C; He B; Beniczky S
    Clin Neurophysiol; 2017 Oct; 128(10):2070-2077. PubMed ID: 28778476
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Computational Models in Electroencephalography.
    Glomb K; Cabral J; Cattani A; Mazzoni A; Raj A; Franceschiello B
    Brain Topogr; 2022 Jan; 35(1):142-161. PubMed ID: 33779888
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The contribution of TMS-EEG coregistration in the exploration of the human cortical connectome.
    Bortoletto M; Veniero D; Thut G; Miniussi C
    Neurosci Biobehav Rev; 2015 Feb; 49():114-24. PubMed ID: 25541459
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A history and review of quantitative electroencephalography in traumatic brain injury.
    Wallace BE; Wagner AK; Wagner EP; McDeavitt JT
    J Head Trauma Rehabil; 2001 Apr; 16(2):165-90. PubMed ID: 11275577
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Brain source localization: a new method based on MUltiple SIgnal Classification algorithm and spatial sparsity of the field signal for electroencephalogram measurements.
    Vergallo P; Lay-Ekuakille A
    Rev Sci Instrum; 2013 Aug; 84(8):085117. PubMed ID: 24007117
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Epileptogenic Source Imaging Using Cross-Frequency Coupled Signals From Scalp EEG.
    Li C; Jacobs D; Hilton T; Campo MD; Chinvarun Y; Carlen PL; Bardakjian BL
    IEEE Trans Biomed Eng; 2016 Dec; 63(12):2607-2618. PubMed ID: 27875126
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Microstates in resting-state EEG: current status and future directions.
    Khanna A; Pascual-Leone A; Michel CM; Farzan F
    Neurosci Biobehav Rev; 2015 Feb; 49():105-13. PubMed ID: 25526823
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.