These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 30732365)

  • 1. Intraoperative OCT for surgical microscope with sensitivity drop and depth of focus correction based on variable focus and dynamic reference.
    Kim JH; Shin JG; Choi ES; Eom TJ
    Opt Express; 2019 Feb; 27(3):3448-3459. PubMed ID: 30732365
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of Microscope-Integrated OCT on Ophthalmology Resident Performance of Anterior Segment Surgical Maneuvers in Model Eyes.
    Todorich B; Shieh C; DeSouza PJ; Carrasco-Zevallos OM; Cunefare DL; Stinnett SS; Izatt JA; Farsiu S; Mruthyunjaya P; Kuo AN; Toth CA
    Invest Ophthalmol Vis Sci; 2016 Jul; 57(9):OCT146-53. PubMed ID: 27409466
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electrically tunable lens integrated with optical coherence tomography angiography for cerebral blood flow imaging in deep cortical layers in mice.
    Li Y; Tang P; Song S; Rakymzhan A; Wang RK
    Opt Lett; 2019 Oct; 44(20):5037-5040. PubMed ID: 31613257
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Analysis of axial scanning range and magnification variation in wide-field microscope for measurement using an electrically tunable lens.
    Qu Y; Hu Y
    Microsc Res Tech; 2019 Feb; 82(2):101-113. PubMed ID: 30451353
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Depth extension and sidelobe suppression in optical coherence tomography using pupil filters.
    Yu X; Liu X; Gu J; Cui D; Wu J; Liu L
    Opt Express; 2014 Nov; 22(22):26956-66. PubMed ID: 25401845
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Enhanced spectral-domain optical coherence tomography (SD-OCT) using in situ ultrasonic virtual tunable optical waveguides.
    Karimi Y; Yang H; Liu J; Park BH; Chamanzar M
    Opt Express; 2022 Sep; 30(19):34256-34275. PubMed ID: 36242442
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multifocal spectral-domain optical coherence tomography based on Bessel beam for extended imaging depth.
    Yi L; Sun L; Ding W
    J Biomed Opt; 2017 Oct; 22(10):1-8. PubMed ID: 29076306
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrically Tunable Lens (ETL)-Based Variable Focus Imaging System for Parametric Surface Texture Analysis of Materials.
    Nirwan JS; Lou S; Hussain S; Nauman M; Hussain T; Conway BR; Ghori MU
    Micromachines (Basel); 2021 Dec; 13(1):. PubMed ID: 35056182
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intraoperative assessment of laryngeal pathologies with optical coherence tomography integrated into a surgical microscope.
    Englhard AS; Betz T; Volgger V; Lankenau E; Ledderose GJ; Stepp H; Homann C; Betz CS
    Lasers Surg Med; 2017 Jul; 49(5):490-497. PubMed ID: 28231390
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Depth-encoded synthetic aperture optical coherence tomography of biological tissues with extended focal depth.
    Mo J; de Groot M; de Boer JF
    Opt Express; 2015 Feb; 23(4):4935-45. PubMed ID: 25836528
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Microscopic OCT imaging with focus extension by ultrahigh-speed acousto-optic tunable lens and stroboscopic illumination.
    Grulkowski I; Szulzycki K; Wojtkowski M
    Opt Express; 2014 Dec; 22(26):31746-60. PubMed ID: 25607144
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Deep imaging with 1.3 µm dual-axis optical coherence tomography and an enhanced depth of focus.
    Jelly ET; Zhao Y; Chu KK; Price H; Crose M; Steelman ZA; Wax A
    Biomed Opt Express; 2021 Dec; 12(12):7689-7702. PubMed ID: 35003860
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Astigmatism corrected common path probe for optical coherence tomography.
    Singh K; Yamada D; Tearney G
    Lasers Surg Med; 2017 Mar; 49(3):312-318. PubMed ID: 27490964
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of a deviated focusing-based optical coherence microscope with a variable depth of focus for high-resolution imaging.
    Saleah SA; Seong D; Wijesinghe RE; Han S; Kim S; Jeon M; Kim J
    Opt Express; 2023 Jan; 31(2):1258-1268. PubMed ID: 36785165
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Microscope-integrated intraoperative OCT with electrically tunable focus and heads-up display for imaging of ophthalmic surgical maneuvers.
    Tao YK; Srivastava SK; Ehlers JP
    Biomed Opt Express; 2014 Jun; 5(6):1877-85. PubMed ID: 24940546
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MEMS-based handheld fourier domain Doppler optical coherence tomography for intraoperative microvascular anastomosis imaging.
    Huang Y; Furtmüller GJ; Tong D; Zhu S; Lee WP; Brandacher G; Kang JU
    PLoS One; 2014; 9(12):e114215. PubMed ID: 25474742
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Endoscopic optical coherence tomography with a focus-adjustable probe.
    Liao W; Chen T; Wang C; Zhang W; Peng Z; Zhang X; Ai S; Fu D; Zhou T; Xue P
    Opt Lett; 2017 Oct; 42(20):4040-4043. PubMed ID: 29028007
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A novel integration of spectral-domain optical-coherence-tomography and laser-ablation system for precision treatment.
    Fan Y; Zhang B; Chang W; Zhang X; Liao H
    Int J Comput Assist Radiol Surg; 2018 Mar; 13(3):411-423. PubMed ID: 28887783
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ultra-high resolution Fourier domain optical coherence tomography for old master paintings.
    Cheung CS; Spring M; Liang H
    Opt Express; 2015 Apr; 23(8):10145-57. PubMed ID: 25969057
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Intraoperative optical coherence tomography in corneal and glaucoma surgical procedures].
    Siebelmann S; Bachmann B; Lappas A; Dietlein T; Hermann M; Roters S; Cursiefen C; Steven P
    Ophthalmologe; 2016 Aug; 113(8):646-50. PubMed ID: 27436117
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.