These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Hearing Preservation Outcomes After Cochlear Implantation Depending on the Angle of Insertion: Indication for Electric or Electric-Acoustic Stimulation. Helbig S; Adel Y; Leinung M; Stöver T; Baumann U; Weissgerber T Otol Neurotol; 2018 Aug; 39(7):834-841. PubMed ID: 29912820 [TBL] [Abstract][Full Text] [Related]
5. Partial deafness treatment with the nucleus straight research array cochlear implant. Skarzynski H; Lorens A; Matusiak M; Porowski M; Skarzynski PH; James CJ Audiol Neurootol; 2012; 17(2):82-91. PubMed ID: 21846981 [TBL] [Abstract][Full Text] [Related]
6. Acceptance and Benefits of Electro-Acoustic Stimulation for Conventional-Length Electrode Arrays. Spitzer ER; Waltzman SB; Landsberger DM; Friedmann DR Audiol Neurootol; 2021; 26(1):17-26. PubMed ID: 32721977 [TBL] [Abstract][Full Text] [Related]
7. Initial Operative Experience and Short-term Hearing Preservation Results With a Mid-scala Cochlear Implant Electrode Array. Svrakic M; Roland JT; McMenomey SO; Svirsky MA Otol Neurotol; 2016 Dec; 37(10):1549-1554. PubMed ID: 27755356 [TBL] [Abstract][Full Text] [Related]
8. Preservation of residual hearing with cochlear implantation: how and why. James C; Albegger K; Battmer R; Burdo S; Deggouj N; Deguine O; Dillier N; Gersdorff M; Laszig R; Lenarz T; Rodriguez MM; Mondain M; Offeciers E; Macías AR; Ramsden R; Sterkers O; Von Wallenberg E; Weber B; Fraysse B Acta Otolaryngol; 2005 May; 125(5):481-91. PubMed ID: 16092537 [TBL] [Abstract][Full Text] [Related]
9. Bilateral electric acoustic stimulation: a comparison of partial and deep cochlear electrode insertion. A longitudinal case study. Kleine Punte A; Vermeire K; Van de Heyning P Adv Otorhinolaryngol; 2010; 67():144-152. PubMed ID: 19955731 [TBL] [Abstract][Full Text] [Related]
11. Insertion of Cochlear Implant Electrode Array Using the Underwater Technique for Preserving Residual Hearing. Anagiotos A; Beutner D; Gostian AO; Schwarz D; Luers JC; Hüttenbrink KB Otol Neurotol; 2016 Apr; 37(4):339-44. PubMed ID: 26945314 [TBL] [Abstract][Full Text] [Related]
12. Slim Modiolar Electrode Placement in Candidates for Electroacoustic Stimulation. Kay-Rivest E; Winchester A; McMenomey SO; Jethanamest D; Roland JT; Friedmann DR Ear Hear; 2023 May-Jun 01; 44(3):566-571. PubMed ID: 36534657 [TBL] [Abstract][Full Text] [Related]
13. Residual hearing conservation and electroacoustic stimulation with the nucleus 24 contour advance cochlear implant. Fraysse B; Macías AR; Sterkers O; Burdo S; Ramsden R; Deguine O; Klenzner T; Lenarz T; Rodriguez MM; Von Wallenberg E; James C Otol Neurotol; 2006 Aug; 27(5):624-33. PubMed ID: 16868510 [TBL] [Abstract][Full Text] [Related]
14. Preservation of hearing in cochlear implant surgery: advantages of combined electrical and acoustical speech processing. Gantz BJ; Turner C; Gfeller KE; Lowder MW Laryngoscope; 2005 May; 115(5):796-802. PubMed ID: 15867642 [TBL] [Abstract][Full Text] [Related]
15. The effects of residual hearing in traditional cochlear implant candidates after implantation with a conventional electrode. Cosetti MK; Friedmann DR; Zhu BZ; Heman-Ackah SE; Fang Y; Keller RG; Shapiro WH; Roland JT; Waltzman SB Otol Neurotol; 2013 Apr; 34(3):516-21. PubMed ID: 23449440 [TBL] [Abstract][Full Text] [Related]
16. Preservation of residual hearing after cochlear implant surgery with slim modiolar electrode. Iso-Mustajärvi M; Sipari S; Löppönen H; Dietz A Eur Arch Otorhinolaryngol; 2020 Feb; 277(2):367-375. PubMed ID: 31673779 [TBL] [Abstract][Full Text] [Related]
17. Phantom Stimulation for Cochlear Implant Users With Residual Low-Frequency Hearing. Krüger B; Büchner A; Nogueira W Ear Hear; 2022; 43(2):631-645. PubMed ID: 34593687 [TBL] [Abstract][Full Text] [Related]
18. Hearing preservation and hearing improvement after reimplantation of pediatric and adult patients with partial deafness: a retrospective case series review. Jayawardena J; Kuthubutheen J; Rajan G Otol Neurotol; 2012 Jul; 33(5):740-4. PubMed ID: 22699985 [TBL] [Abstract][Full Text] [Related]
19. Optimizing maps for electric acoustic stimulation users. Yoon YS; Shin YR; Kim JM; Coltisor A; Chun YM Cochlear Implants Int; 2019 May; 20(3):106-115. PubMed ID: 30694120 [TBL] [Abstract][Full Text] [Related]
20. Radiologic Results and Hearing Preservation With a Straight Narrow Electrode via Round Window Versus Cochleostomy Approach at Initial Activation. Hassepass F; Aschendorff A; Bulla S; Arndt S; Maier W; Laszig R; Beck R Otol Neurotol; 2015 Jul; 36(6):993-1000. PubMed ID: 25675315 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]