176 related articles for article (PubMed ID: 30744156)
1. Continuous Separation of Circulating Tumor Cells from Whole Blood Using a Slanted Weir Microfluidic Device.
Yoon Y; Lee J; Ra M; Gwon H; Lee S; Kim MY; Yoo KC; Sul O; Kim CG; Kim WY; Park JG; Lee SJ; Lee YY; Choi HS; Lee SB
Cancers (Basel); 2019 Feb; 11(2):. PubMed ID: 30744156
[TBL] [Abstract][Full Text] [Related]
2. Enrichment of Circulating Tumor Cells from Whole Blood Using a Microfluidic Device for Sequential Physical and Magnetophoretic Separations.
Lee J; Sul O; Lee SB
Micromachines (Basel); 2020 May; 11(5):. PubMed ID: 32384825
[TBL] [Abstract][Full Text] [Related]
3. Continuous Flow Deformability-Based Separation of Circulating Tumor Cells Using Microfluidic Ratchets.
Park ES; Jin C; Guo Q; Ang RR; Duffy SP; Matthews K; Azad A; Abdi H; Todenhöfer T; Bazov J; Chi KN; Black PC; Ma H
Small; 2016 Apr; 12(14):1909-19. PubMed ID: 26917414
[TBL] [Abstract][Full Text] [Related]
4. A new insight to deformability correlation of circulating tumor cells with metastatic behavior by application of a new deformability-based microfluidic chip.
Hakim M; Khorasheh F; Alemzadeh I; Vossoughi M
Anal Chim Acta; 2021 Nov; 1186():339115. PubMed ID: 34756251
[TBL] [Abstract][Full Text] [Related]
5. Isolation and detection of circulating tumour cells from metastatic melanoma patients using a slanted spiral microfluidic device.
Aya-Bonilla CA; Marsavela G; Freeman JB; Lomma C; Frank MH; Khattak MA; Meniawy TM; Millward M; Warkiani ME; Gray ES; Ziman M
Oncotarget; 2017 Sep; 8(40):67355-67368. PubMed ID: 28978038
[TBL] [Abstract][Full Text] [Related]
6. Microfluidic Immiscible Phase Filtration System for the Isolation of Small Numbers of Cells from Whole Blood.
Pirozzi I; Snider A; Kraus M; Schönbrunner ER; Tripathi A
Cytometry A; 2019 Aug; 95(8):885-897. PubMed ID: 30852843
[TBL] [Abstract][Full Text] [Related]
7. Slanted spiral microfluidics for the ultra-fast, label-free isolation of circulating tumor cells.
Warkiani ME; Guan G; Luan KB; Lee WC; Bhagat AA; Chaudhuri PK; Tan DS; Lim WT; Lee SC; Chen PC; Lim CT; Han J
Lab Chip; 2014 Jan; 14(1):128-37. PubMed ID: 23949794
[TBL] [Abstract][Full Text] [Related]
8. Efficient separation of tumor cells from untreated whole blood using a novel multistage hydrodynamic focusing microfluidics.
Gao R; Cheng L; Wang S; Bi X; Wang X; Wang R; Chen X; Zha Z; Wang F; Xu X; Zhao G; Yu L
Talanta; 2020 Jan; 207():120261. PubMed ID: 31594567
[TBL] [Abstract][Full Text] [Related]
9. Size-selective microcavity array for rapid and efficient detection of circulating tumor cells.
Hosokawa M; Hayata T; Fukuda Y; Arakaki A; Yoshino T; Tanaka T; Matsunaga T
Anal Chem; 2010 Aug; 82(15):6629-35. PubMed ID: 20583799
[TBL] [Abstract][Full Text] [Related]
10. Integrated Microfluidic Device for Enrichment and Identification of Circulating Tumor Cells from the Blood of Patients with Colorectal Cancer.
Su W; Yu H; Jiang L; Chen W; Li H; Qin J
Dis Markers; 2019; 2019():8945974. PubMed ID: 31354892
[TBL] [Abstract][Full Text] [Related]
11. Microfluidic Separation of Circulating Tumor Cells Based on Size and Deformability.
Park ES; Duffy SP; Ma H
Methods Mol Biol; 2017; 1634():21-32. PubMed ID: 28819838
[TBL] [Abstract][Full Text] [Related]
12. A novel microfluidic platform for size and deformability based separation and the subsequent molecular characterization of viable circulating tumor cells.
Hvichia GE; Parveen Z; Wagner C; Janning M; Quidde J; Stein A; Müller V; Loges S; Neves RP; Stoecklein NH; Wikman H; Riethdorf S; Pantel K; Gorges TM
Int J Cancer; 2016 Jun; 138(12):2894-904. PubMed ID: 26789903
[TBL] [Abstract][Full Text] [Related]
13. Size-selective collection of circulating tumor cells using Vortex technology.
Sollier E; Go DE; Che J; Gossett DR; O'Byrne S; Weaver WM; Kummer N; Rettig M; Goldman J; Nickols N; McCloskey S; Kulkarni RP; Di Carlo D
Lab Chip; 2014 Jan; 14(1):63-77. PubMed ID: 24061411
[TBL] [Abstract][Full Text] [Related]
14. Progress in Circulating Tumor Cell Research Using Microfluidic Devices.
Gwak H; Kim J; Kashefi-Kheyrabadi L; Kwak B; Hyun KA; Jung HI
Micromachines (Basel); 2018 Jul; 9(7):. PubMed ID: 30424286
[TBL] [Abstract][Full Text] [Related]
15. Microfluidic-Based Enrichment and Retrieval of Circulating Tumor Cells for RT-PCR Analysis.
Gogoi P; Sepehri S; Chow W; Handique K; Wang Y
Methods Mol Biol; 2017; 1634():55-64. PubMed ID: 28819840
[TBL] [Abstract][Full Text] [Related]
16. Acoustic separation of circulating tumor cells.
Li P; Mao Z; Peng Z; Zhou L; Chen Y; Huang PH; Truica CI; Drabick JJ; El-Deiry WS; Dao M; Suresh S; Huang TJ
Proc Natl Acad Sci U S A; 2015 Apr; 112(16):4970-5. PubMed ID: 25848039
[TBL] [Abstract][Full Text] [Related]
17. Wedge-shaped microfluidic chip for circulating tumor cells isolation and its clinical significance in gastric cancer.
Yang C; Zhang N; Wang S; Shi D; Zhang C; Liu K; Xiong B
J Transl Med; 2018 May; 16(1):139. PubMed ID: 29792200
[TBL] [Abstract][Full Text] [Related]
18. Size-based separation methods of circulating tumor cells.
Hao SJ; Wan Y; Xia YQ; Zou X; Zheng SY
Adv Drug Deliv Rev; 2018 Feb; 125():3-20. PubMed ID: 29326054
[TBL] [Abstract][Full Text] [Related]
19. All-in-one centrifugal microfluidic device for size-selective circulating tumor cell isolation with high purity.
Lee A; Park J; Lim M; Sunkara V; Kim SY; Kim GH; Kim MH; Cho YK
Anal Chem; 2014 Nov; 86(22):11349-56. PubMed ID: 25317565
[TBL] [Abstract][Full Text] [Related]
20. Fast and Label-Free Isolation of Circulating Tumor Cells from Blood: From a Research Microfluidic Platform to an Automated Fluidic Instrument, VTX-1 Liquid Biopsy System.
Lemaire CA; Liu SZ; Wilkerson CL; Ramani VC; Barzanian NA; Huang KW; Che J; Chiu MW; Vuppalapaty M; Dimmick AM; Carlo DD; Kochersperger ML; Crouse SC; Jeffrey SS; Englert RF; Hengstler S; Renier C; Sollier-Christen E
SLAS Technol; 2018 Feb; 23(1):16-29. PubMed ID: 29355087
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]