These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 30745558)

  • 1. Use of 3D Volume Rendering Based on High-Resolution Computed Tomography Temporal Bone in Patients with Cochlear Implants.
    Ciodaro F; Freni F; Mannella VK; Gazia F; Maceri A; Bruno R; Galletti B; Galletti F
    Am J Case Rep; 2019 Feb; 20():184-188. PubMed ID: 30745558
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Three-dimensional imaging of the temporal bone using a helical CT scan and its application in patients with cochlear implantation.
    Himi T; Kataura A; Sakata M; Odawara Y; Satoh JI; Sawaishi M
    ORL J Otorhinolaryngol Relat Spec; 1996; 58(6):298-300. PubMed ID: 8958535
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Flat-panel volume computed tomography for cochlear implant electrode array examination in isolated temporal bone specimens.
    Bartling SH; Gupta R; Torkos A; Dullin C; Eckhardt G; Lenarz T; Becker H; Stöver T
    Otol Neurotol; 2006 Jun; 27(4):491-8. PubMed ID: 16791040
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cone-beam CT versus Multidetector CT in Postoperative Cochlear Implant Imaging: Evaluation of Image Quality and Radiation Dose.
    Helal RA; Jacob R; Elshinnawy MA; Othman AI; Al-Dhamari IM; Paulus DW; Abdelaziz TT
    AJNR Am J Neuroradiol; 2021 Jan; 42(2):362-367. PubMed ID: 33414229
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the middle and inner ear structures: comparison of hybrid rendering, virtual endoscopy and axial 2D source images.
    Seemann MD; Seemann O; Bonél H; Suckfüll M; Englmeier KH; Naumann A; Allen CM; Reiser MF
    Eur Radiol; 1999; 9(9):1851-8. PubMed ID: 10602962
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of object-to-detector distance and beam energy on synchrotron radiation phase-contrast imaging of implanted cochleae.
    Rohani SA; Iyaniwura JE; Zhu N; Agrawal SK; Ladak HM
    J Microsc; 2019 Feb; 273(2):127-134. PubMed ID: 30431166
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Hybrid 3D visualization and virtual endoscopy in cochlear implants].
    Seemann MD; Luboldt W; Haferkamp C; Bode A; Schäfer J; Allen CM; Dammann F; Plinkert P; Claussen CD
    Rofo; 2000 Mar; 172(3):238-43. PubMed ID: 10778454
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the implanted cochlear implant electrode by CT scanning with three-dimensional reconstruction.
    Kong WJ; Cheng HM; Ma H; Wang YJ; Han P
    Acta Otolaryngol; 2012 Feb; 132(2):116-22. PubMed ID: 22053975
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optimal electrode diameter in relation to volume of the cochlea.
    Gnansia D; Demarcy T; Vandersteen C; Raffaelli C; Guevara N; Delingette H; Ayache N
    Eur Ann Otorhinolaryngol Head Neck Dis; 2016 Jun; 133 Suppl 1():S66-7. PubMed ID: 27246746
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Computed tomography and/or magnetic resonance imaging before pediatric cochlear implantation? Developing an investigative strategy.
    Trimble K; Blaser S; James AL; Papsin BC
    Otol Neurotol; 2007 Apr; 28(3):317-24. PubMed ID: 17414036
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radiologic examinations in human temporal bone specimens using digital volume tomography and high-resolution computed tomography after implantation of middle ear prosthesis and cochlear implant electrode array.
    Bremke M; Lüers JC; Stenner M; Bovenschulte H; Dorn F; Unkel C; Höllering J; Beutner D
    Otol Neurotol; 2013 Sep; 34(7):1321-8. PubMed ID: 23739552
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Computed tomography and magnetic resonance tomography of the normal temporal bone].
    Czerny C; Franz P; Imhof H
    Radiologe; 2003 Mar; 43(3):200-6. PubMed ID: 12664234
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Anatomical Characteristics of Facial Nerve and Cochlea Interaction.
    Schart-Morén N; Larsson S; Rask-Andersen H; Li H
    Audiol Neurootol; 2017; 22(1):41-49. PubMed ID: 28628917
    [TBL] [Abstract][Full Text] [Related]  

  • 14. HRCT and MRI findings in X-linked non-syndromic deafness patients with a POU3F4 mutation.
    Gong WX; Gong RZ; Zhao B
    Int J Pediatr Otorhinolaryngol; 2014 Oct; 78(10):1756-62. PubMed ID: 25175280
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-resolution in situ imaging of cochlear implant electrode arrays in cat temporal bones using Tuned Aperture Computed Tomography (TACT).
    Sakata M; Hareyama M; Heil TA; Henson MM; Henson OW; Webber RL; Nair MK; Smith DW
    Ear Hear; 2007 Aug; 28(4):435-43. PubMed ID: 17609606
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dyna-CT of the temporal bone for case-specific three-dimensional rendering of the stapedial muscle for planning of electrically evoked stapedius reflex threshold determination during cochlear implantation directly from the stapedius muscle via a retrofacial approach: a pilot study.
    Volk GF; Aschenbach R; Gadyuchko M; Bitter T; Koscielny S; Teichgräber U; Guntinas-Lichius O
    Eur Arch Otorhinolaryngol; 2020 Apr; 277(4):975-985. PubMed ID: 31897721
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Value of multidetector computed tomography in detection of congenital inner ear malformations and its usefulness in qualification for cochlear implantation].
    Furmanek MI; Piotrowska A; Skarzyński H; Bogusławska-Walecka R; Walecki J
    Otolaryngol Pol; 2007; 61(4):585-90. PubMed ID: 18260257
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Aspects of temporal bone anatomy and pathology in conjunction with cochlear implant surgery.
    Stjernholm C
    Acta Radiol Suppl; 2003 Jul; 430():2-15. PubMed ID: 12834396
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The misplaced cochlear implant electrode array.
    Mehanna AM; Gamaleldin OA; Fathalla MF
    Int J Pediatr Otorhinolaryngol; 2019 Feb; 117():96-104. PubMed ID: 30579097
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cochlear implants: Insertion assessment by computed tomography.
    Menegatti Pavan AL; Alves AFF; Giacomini G; Altemani JMC; Castilho AM; Lauria RA; da Silva VAR; Guimarães AC; de Pina DR
    Am J Otolaryngol; 2018; 39(4):431-435. PubMed ID: 29685378
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.