206 related articles for article (PubMed ID: 30762325)
21. [Patient-ventilator interaction].
Gürsel G; Aydoğdu M
Tuberk Toraks; 2009; 57(4):453-65. PubMed ID: 20037864
[TBL] [Abstract][Full Text] [Related]
22. Ability of ICU Health-Care Professionals to Identify Patient-Ventilator Asynchrony Using Waveform Analysis.
Ramirez II; Arellano DH; Adasme RS; Landeros JM; Salinas FA; Vargas AG; Vasquez FJ; Lobos IA; Oyarzun ML; Restrepo RD
Respir Care; 2017 Feb; 62(2):144-149. PubMed ID: 28108684
[TBL] [Abstract][Full Text] [Related]
23. Early Noninvasive Neurally Adjusted Ventilatory Assist Versus Noninvasive Flow-Triggered Pressure Support Ventilation in Pediatric Acute Respiratory Failure: A Physiologic Randomized Controlled Trial.
Chidini G; De Luca D; Conti G; Pelosi P; Nava S; Calderini E
Pediatr Crit Care Med; 2016 Nov; 17(11):e487-e495. PubMed ID: 27749511
[TBL] [Abstract][Full Text] [Related]
24. Neurally adjusted ventilatory assist: a ventilation tool or a ventilation toy?
Verbrugghe W; Jorens PG
Respir Care; 2011 Mar; 56(3):327-35. PubMed ID: 21255496
[TBL] [Abstract][Full Text] [Related]
25. Patient-ventilator asynchrony in acute brain-injured patients: a prospective observational study.
Luo XY; He X; Zhou YM; Wang YM; Chen JR; Chen GQ; Li HL; Yang YL; Zhang L; Zhou JX
Ann Intensive Care; 2020 Oct; 10(1):144. PubMed ID: 33074406
[TBL] [Abstract][Full Text] [Related]
26. How often does patient-ventilator asynchrony occur and what are the consequences?
Epstein SK
Respir Care; 2011 Jan; 56(1):25-38. PubMed ID: 21235836
[TBL] [Abstract][Full Text] [Related]
27. Patient-ventilator asynchrony.
Holanda MA; Vasconcelos RDS; Ferreira JC; Pinheiro BV
J Bras Pneumol; 2018; 44(4):321-333. PubMed ID: 30020347
[TBL] [Abstract][Full Text] [Related]
28. Longitudinal Changes in Patient-Ventilator Asynchronies and Respiratory System Mechanics Before and After Tracheostomy.
Lena E; Aquino-Esperanza J; López-Aguilar J; Magrans R; de Haro C; Sarlabous L; López N; Montanyà J; Rué M; Kacmarek RM; Lucangelo U; Fernández R; Pelosi P; Blanch L;
Respir Care; 2021 Sep; 66(9):1389-1397. PubMed ID: 34230215
[TBL] [Abstract][Full Text] [Related]
29. Neurally adjusted ventilator assist (NAVA) reduces asynchrony during non-invasive ventilation for severe bronchiolitis.
Baudin F; Pouyau R; Cour-Andlauer F; Berthiller J; Robert D; Javouhey E
Pediatr Pulmonol; 2015 Dec; 50(12):1320-7. PubMed ID: 25488197
[TBL] [Abstract][Full Text] [Related]
30. Patient-ventilator interactions. Implications for clinical management.
Gilstrap D; MacIntyre N
Am J Respir Crit Care Med; 2013 Nov; 188(9):1058-68. PubMed ID: 24070493
[TBL] [Abstract][Full Text] [Related]
31. Asynchronies during mechanical ventilation are associated with mortality.
Blanch L; Villagra A; Sales B; Montanya J; Lucangelo U; Luján M; García-Esquirol O; Chacón E; Estruga A; Oliva JC; Hernández-Abadia A; Albaiceta GM; Fernández-Mondejar E; Fernández R; Lopez-Aguilar J; Villar J; Murias G; Kacmarek RM
Intensive Care Med; 2015 Apr; 41(4):633-41. PubMed ID: 25693449
[TBL] [Abstract][Full Text] [Related]
32. Oral hygiene care for critically ill patients to prevent ventilator-associated pneumonia.
Shi Z; Xie H; Wang P; Zhang Q; Wu Y; Chen E; Ng L; Worthington HV; Needleman I; Furness S
Cochrane Database Syst Rev; 2013 Aug; (8):CD008367. PubMed ID: 23939759
[TBL] [Abstract][Full Text] [Related]
33. Prevalence and Prognosis Impact of Patient-Ventilator Asynchrony in Early Phase of Weaning according to Two Detection Methods.
Rolland-Debord C; Bureau C; Poitou T; Belin L; Clavel M; Perbet S; Terzi N; Kouatchet A; Similowski T; Demoule A
Anesthesiology; 2017 Dec; 127(6):989-997. PubMed ID: 28914623
[TBL] [Abstract][Full Text] [Related]
34. Patient-ventilator asynchrony during non-invasive ventilation for acute respiratory failure: a multicenter study.
Vignaux L; Vargas F; Roeseler J; Tassaux D; Thille AW; Kossowsky MP; Brochard L; Jolliet P
Intensive Care Med; 2009 May; 35(5):840-6. PubMed ID: 19183949
[TBL] [Abstract][Full Text] [Related]
35. Neurally adjusted ventilatory assist mitigates ventilator-induced diaphragm injury in rabbits.
Shimatani T; Shime N; Nakamura T; Ohshimo S; Hotz J; Khemani RG
Respir Res; 2019 Dec; 20(1):293. PubMed ID: 31870367
[TBL] [Abstract][Full Text] [Related]
36. Neurally adjusted ventilatory assist and proportional assist ventilation both improve patient-ventilator interaction.
Schmidt M; Kindler F; Cecchini J; Poitou T; Morawiec E; Persichini R; Similowski T; Demoule A
Crit Care; 2015 Feb; 19(1):56. PubMed ID: 25879592
[TBL] [Abstract][Full Text] [Related]
37. Automated detection of patient-ventilator asynchrony: new tool or new toy?
Piquilloud L; Jolliet P; Revelly JP
Crit Care; 2013 Nov; 17(6):1015. PubMed ID: 24252458
[TBL] [Abstract][Full Text] [Related]
38. Monitoring patient-ventilator asynchrony.
Dres M; Rittayamai N; Brochard L
Curr Opin Crit Care; 2016 Jun; 22(3):246-53. PubMed ID: 27070802
[TBL] [Abstract][Full Text] [Related]
39. Monitoring Asynchrony During Invasive Mechanical Ventilation.
Esperanza JA; Sarlabous L; de Haro C; Magrans R; Lopez-Aguilar J; Blanch L
Respir Care; 2020 Jun; 65(6):847-869. PubMed ID: 32457175
[TBL] [Abstract][Full Text] [Related]
40. Effectiveness and safety of Neurally Adjusted Ventilatory Assist (NAVA) mechanical ventilation compared to standard conventional mechanical ventilation in optimizing patient-ventilator synchrony in critically ill patients: a systematic review protocol.
Patthum A; Peters M; Lockwood C
JBI Database System Rev Implement Rep; 2015 Apr; 13(3):31-46. PubMed ID: 26447047
[No Abstract] [Full Text] [Related]
[Previous] [Next] [New Search]