These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

242 related articles for article (PubMed ID: 30763527)

  • 1. Titanium Lag Screw Versus Miniplate Fixation in the Treatment of Anterior Mandibular Fractures.
    Tiwari M; Meshram V; Lambade P; Fernandes G
    J Oral Maxillofac Surg; 2019 May; 77(5):1031-1039. PubMed ID: 30763527
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Comparative Evaluation of Fixation Techniques in Anterior Mandibular Fractures Using 2.0 mm Monocortical Titanium Miniplates Versus 2.4 mm Cortical Titanium Lag Screws.
    Goyal M; Jhamb A; Chawla S; Marya K; Dua JS; Yadav S
    J Maxillofac Oral Surg; 2012 Dec; 11(4):442-50. PubMed ID: 24293938
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparative study of intermaxillary fixation screws and noncompression miniplates in the treatment of mandibular fractures: a prospective clinical study.
    Anslem O; Eyituoyo O; Olabode OV; Ademola OA; Adesina AO
    Oral Maxillofac Surg; 2017 Jun; 21(2):233-240. PubMed ID: 28386782
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of miniplate versus lag-screw osteosynthesis for fractures of the mandibular angle.
    Schaaf H; Kaubruegge S; Streckbein P; Wilbrand JF; Kerkmann H; Howaldt HP
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2011 Jan; 111(1):34-40. PubMed ID: 20598593
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparative study between traditional fixation with miniplates and modified lag screws for the treatment of mandibular fractures.
    García Carricondo AR; Quesada Bravo FJ; Espín Gálvez F; Parrón Carreño T; Alarcón Rodriguez R
    Clin Oral Investig; 2018 Apr; 22(3):1503-1511. PubMed ID: 29038962
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparative evaluation of osteosynthesis with lag screws, miniplates, or Kirschner wires for mandibular condylar process fractures.
    Sugiura T; Yamamoto K; Murakami K; Sugimura M
    J Oral Maxillofac Surg; 2001 Oct; 59(10):1161-8; discussion 1169-70. PubMed ID: 11573172
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Can an arch bar replace a second lag screw in management of anterior mandibular fractures?
    Emam HA; Stevens MR
    J Oral Maxillofac Surg; 2012 Feb; 70(2):378-83. PubMed ID: 22079063
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three-dimensional v/s standard titanium miniplate fixation in the management of mandibular fractures--a randomized clinical study.
    Sehgal S; Ramanujam L; Prasad K; Krishnappa R
    J Craniomaxillofac Surg; 2014 Oct; 42(7):1292-9. PubMed ID: 24780350
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Miniplate fixation of fractures of the symphyseal and parasymphyseal regions of the mandible: a review of 218 patients.
    Lee T; Sawhney R; Ducic Y
    JAMA Facial Plast Surg; 2013 Mar; 15(2):121-5. PubMed ID: 23303108
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparative analysis of the efficacy of cortical screws as lag screws and miniplates for internal fixation of mandibular symphyseal region fractures: a randomized prospective study.
    Agnihotri A; Prabhu S; Thomas S
    Int J Oral Maxillofac Surg; 2014 Jan; 43(1):22-8. PubMed ID: 23928155
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Treatment modalities for mandibular angle fractures.
    Gear AJ; Apasova E; Schmitz JP; Schubert W
    J Oral Maxillofac Surg; 2005 May; 63(5):655-63. PubMed ID: 15883941
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of labial versus labio-inferior lines of osteosynthesis using 3D miniplate for fractures of anterior mandible: A finite element analysis with a pilot clinical trial.
    Ponvel K; Panneerselvam E; Balasubramanian S; Krishna Kumar Raja VB
    Chin J Traumatol; 2019 Oct; 22(5):261-269. PubMed ID: 31493976
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of bite force evaluation for mandibular angle fracture fixation by conventional miniplates versus new design miniplates: a clinical study.
    Gamit M; Patel Y; Sood R; Vadera H; Savjani K; Bhatti Z
    Oral Maxillofac Surg; 2024 Jun; 28(2):645-652. PubMed ID: 37740128
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transverse displacement of the proximal segment after bilateral sagittal osteotomy: a comparison of lag screw fixation versus miniplates with monocortical screw technique.
    Becktor JP; Rebellato J; Sollenius O; Vedtofte P; Isaksson S
    J Oral Maxillofac Surg; 2008 Jan; 66(1):104-11. PubMed ID: 18083423
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Herbert Cannulated Bone Screw Osteosynthesis in Anterior Mandibular Fracture Treatment: A Comparative Study With Lag Screw and Miniplate.
    El-Mahallawy Y; Al-Mahalawy H
    J Oral Maxillofac Surg; 2018 Jun; 76(6):1281.e1-1281.e8. PubMed ID: 29549016
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Width-Controlling Fixation of Symphyseal/Parasymphyseal Fractures Associated With Bilateral Condylar Fractures With 2 2.0-mm Miniplates: A Retrospective Investigation of 45 Cases.
    Chen S; Zhang Y; An JG; He Y
    J Oral Maxillofac Surg; 2016 Feb; 74(2):315-27. PubMed ID: 26514631
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A clinical prospective randomized comparative study on ostyeosynthesis of mandibular anterior fractures following open reduction using lag screws and miniplates.
    Mittal G; Aggrawal A; Garg R; Sharma S; Rathi A; Sharma V
    Natl J Maxillofac Surg; 2017; 8(2):110-116. PubMed ID: 29386813
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mandibular angle fractures: two-miniplate fixation and complications.
    Fox AJ; Kellman RM
    Arch Facial Plast Surg; 2003; 5(6):464-9. PubMed ID: 14623682
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Is lag screw fixation superior to plate fixation to treat fractures of the mandibular symphysis?
    Ellis E
    J Oral Maxillofac Surg; 2012 Apr; 70(4):875-82. PubMed ID: 22209100
    [TBL] [Abstract][Full Text] [Related]  

  • 20. "A comparative evaluation between single noncompression titanium miniplate and three dimensional titanium miniplate in treatment of mandibular angle fracture"--a randomized prospective study.
    Vineeth K; Lalitha RM; Prasad K; Ranganath K; Shwetha V; Singh J
    J Craniomaxillofac Surg; 2013 Mar; 41(2):103-9. PubMed ID: 22809633
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.