330 related articles for article (PubMed ID: 30767784)
1. The impact of plate length, fibula integrity and plate placement on tibial shaft fixation stability: a finite element study.
Cao Y; Zhang Y; Huang L; Huang X
J Orthop Surg Res; 2019 Feb; 14(1):52. PubMed ID: 30767784
[TBL] [Abstract][Full Text] [Related]
2. Comparison of tibial fracture plate length, placement, and fibular integrity effects on plate integrity through finite element analysis.
Lee BH; Kang Y; Cho SH; Moon M; Sim JA; Kim J
Sci Rep; 2024 Jun; 14(1):14538. PubMed ID: 38914709
[TBL] [Abstract][Full Text] [Related]
3. Finite element analysis of intramedullary nailing and double locking plate for treating extra-articular proximal tibial fractures.
Chen F; Huang X; Ya Y; Ma F; Qian Z; Shi J; Guo S; Yu B
J Orthop Surg Res; 2018 Jan; 13(1):12. PubMed ID: 29338748
[TBL] [Abstract][Full Text] [Related]
4. Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study.
Huang X; Zhi Z; Yu B; Chen F
J Orthop Surg Res; 2015 Nov; 10():182. PubMed ID: 26608217
[TBL] [Abstract][Full Text] [Related]
5. [Finite element study of three novel internal fixation modes for bicondylar four-quadrant fractures of tibial plateau].
Liu C; Hu S; Chang S
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Mar; 37(3):290-295. PubMed ID: 36940986
[TBL] [Abstract][Full Text] [Related]
6. Finite element analysis of the stability of AO/OTA 43-C1 type distal tibial fractures treated with distal tibia medial anatomic plate versus anterolateral anatomic plate.
Oken OF; Yildirim AO; Asilturk M
Acta Orthop Traumatol Turc; 2017 Oct; 51(5):404-408. PubMed ID: 28986074
[TBL] [Abstract][Full Text] [Related]
7. Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study.
Chen P; Lu H; Shen H; Wang W; Ni B; Chen J
J Orthop Surg Res; 2017 Feb; 12(1):35. PubMed ID: 28231839
[TBL] [Abstract][Full Text] [Related]
8. Finite element analysis comparison of Type 42A2 fracture fixed with external titanium alloy locking plate and traditional external fixation frame.
Fang S; Zhang L; Yang Y; Wang Y; Guo J; Mi L
J Orthop Surg Res; 2023 Oct; 18(1):815. PubMed ID: 37907959
[TBL] [Abstract][Full Text] [Related]
9. Finite element analysis of different locking plate fixation methods for the treatment of ulnar head fracture.
Zhang Y; Shao Q; Yang C; Ai C; Zhou D; Yu Y; Sun G
J Orthop Surg Res; 2021 Mar; 16(1):191. PubMed ID: 33722253
[TBL] [Abstract][Full Text] [Related]
10. An intact fibula may contribute to allow early weight bearing in surgically treated tibial plateau fractures.
Carrera I; Gelber PE; Chary G; Gomez Masdeu M; González Ballester MA; Monllau JC; Noailly J
Knee Surg Sports Traumatol Arthrosc; 2018 Mar; 26(3):756-761. PubMed ID: 28255659
[TBL] [Abstract][Full Text] [Related]
11. The effect of concurrent fibular fracture on the fixation of distal tibia fractures: a laboratory comparison of intramedullary nails with locked plates.
Strauss EJ; Alfonso D; Kummer FJ; Egol KA; Tejwani NC
J Orthop Trauma; 2007 Mar; 21(3):172-7. PubMed ID: 17473753
[TBL] [Abstract][Full Text] [Related]
12. Plating System Design Determines Mechanical Environment in Long Bone Mid-shaft Fractures: A Finite Element Analysis.
Wang J; Zhang X; Li S; Yin B; Liu G; Cheng X; Zhang Y
J Invest Surg; 2020 Sep; 33(8):699-708. PubMed ID: 30885085
[No Abstract] [Full Text] [Related]
13. Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis.
Blažević D; Kodvanj J; Adamović P; Vidović D; Trobonjača Z; Sabalić S
J Orthop Surg Res; 2022 Jan; 17(1):16. PubMed ID: 35016716
[TBL] [Abstract][Full Text] [Related]
14. Biomechanical effect of the configuration of screw hole style on locking plate fixation in proximal humerus fracture with a simulated gap: A finite element analysis.
Zhang YK; Wei HW; Lin KP; Chen WC; Tsai CL; Lin KJ
Injury; 2016 Jun; 47(6):1191-5. PubMed ID: 26975793
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical evaluation of different fixation methods for fracture dislocation involving the proximal tibia.
Jiang R; Luo CF; Zeng BF
Clin Biomech (Bristol, Avon); 2008 Oct; 23(8):1059-64. PubMed ID: 18486288
[TBL] [Abstract][Full Text] [Related]
16. Effect of fibular plate fixation on rotational stability of simulated distal tibial fractures treated with intramedullary nailing.
Kumar A; Charlebois SJ; Cain EL; Smith RA; Daniels AU; Crates JM
J Bone Joint Surg Am; 2003 Apr; 85(4):604-8. PubMed ID: 12672833
[TBL] [Abstract][Full Text] [Related]
17. A Novel Locking Buttress Plate Designed for Simultaneous Medial and Posterolateral Tibial Plateau Fractures: Concept and Comparative Finite Element Analysis.
Yan B; Huang X; Xu Y; Zou C
Orthop Surg; 2023 Apr; 15(4):1104-1116. PubMed ID: 36793219
[TBL] [Abstract][Full Text] [Related]
18. Biomechanics of the Injured Fibula Following Plate Fixation of a Concomitant Tibia Fracture To Fix or Not to Fix?
Onyekwelu I; Sinicrope BJ; Riehl JT; Roberts CS; Voor MJ
Bull Hosp Jt Dis (2013); 2018 Sep; 76(3):176-182. PubMed ID: 31513521
[TBL] [Abstract][Full Text] [Related]
19. Mechanical performance and implications on bone healing of different screw configurations for plate fixation of diaphyseal tibia fractures: a computational study.
Travascio F; Buller LT; Milne E; Latta L
Eur J Orthop Surg Traumatol; 2021 Jan; 31(1):121-130. PubMed ID: 32725431
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of Fibular Fracture Type vs Location of Tibial Fixation of Pilon Fractures.
Busel GA; Watson JT; Israel H
Foot Ankle Int; 2017 Jun; 38(6):650-655. PubMed ID: 28288519
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]