These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
153 related articles for article (PubMed ID: 30782504)
1. Spinal dural closure without suture: Minimizing the risk of CSF leakage with a flat non-penetrating titanium U-clip. Marin Laut FM; Gómez Cárdenas EA; Dormido JR; Molina NM; López López JA Neurocirugia (Astur : Engl Ed); 2019; 30(4):173-178. PubMed ID: 30782504 [TBL] [Abstract][Full Text] [Related]
2. Utility of nonpenetrating titanium clips for dural closure during spinal surgery to prevent postoperative cerebrospinal fluid leakage. Ito K; Aoyama T; Horiuchi T; Hongo K J Neurosurg Spine; 2015 Dec; 23(6):812-9. PubMed ID: 26315957 [TBL] [Abstract][Full Text] [Related]
3. Spinal dural closure with nonpenetrating titanium clips in pediatric neurosurgery. Kaufman BA; Matthews AE; Zwienenberg-Lee M; Lew SM J Neurosurg Pediatr; 2010 Oct; 6(4):359-63. PubMed ID: 20887109 [TBL] [Abstract][Full Text] [Related]
4. Novel use of nonpenetrating titanium clips for pediatric primary spinal dural closure: A technical note. Shahrestani S; Brown NJ; Loya J; Patel NA; Gendreau JL; Himstead AS; Pierzchajlo N; Singh R; Sahyouni R; Diaz-Aguilar LD; Rennert RC; Levy ML Clin Neurol Neurosurg; 2022 Nov; 222():107422. PubMed ID: 36084429 [TBL] [Abstract][Full Text] [Related]
5. Novel dural incision and closure procedure for preventing postoperative cerebrospinal fluid leakage during the surgical removal of dumbbell-shaped spinal tumors: technical note. Ito K; Aoyama T; Nakamura T; Hanaoka Y; Horiuchi T; Hongo K J Neurosurg Spine; 2016 Nov; 25(5):620-625. PubMed ID: 27285668 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of Metallic Artifacts Caused by Nonpenetrating Titanium Clips in Postoperative Neuroimaging. Ito K; Seguchi T; Nakamura T; Chiba A; Hasegawa T; Nagm A; Horiuchi T; Hongo K World Neurosurg; 2016 Dec; 96():16-22. PubMed ID: 27586178 [TBL] [Abstract][Full Text] [Related]
7. Efficacy of intraoperative lumbar subarachnoid drainage for prevention of cerebrospinal fluid leak after spinal cord tumor resection. Kobayashi K; Ando K; Ito K; Tsushima M; Matsumoto A; Morozumi M; Tanaka S; Machino M; Ishiguro N; Imagama S J Orthop Sci; 2018 Mar; 23(2):266-272. PubMed ID: 29191390 [TBL] [Abstract][Full Text] [Related]
8. The use of a novel perfusion-based cadaveric simulation model with cerebrospinal fluid reconstitution comparing dural repair techniques: a pilot study. Bakhsheshian J; Strickland BA; Patel NN; Jakoi AM; Minneti M; Zada G; Acosta FL; Hsieh PC; Wang JC; Liu JC; Pham MH Spine J; 2017 Sep; 17(9):1335-1341. PubMed ID: 28412565 [TBL] [Abstract][Full Text] [Related]
9. Dural Closure in Confined Spaces of the Skull Base with Nonpenetrating Titanium Clips. Glenn CA; Baker CM; Burks JD; Conner AK; Smitherman AD; Sughrue ME Oper Neurosurg (Hagerstown); 2018 Apr; 14(4):375-385. PubMed ID: 28973649 [TBL] [Abstract][Full Text] [Related]
10. Dural substitute with polyglycolic acid mesh and fibrin glue for dural repair: technical note and preliminary results. Shimada Y; Hongo M; Miyakoshi N; Sugawara T; Kasukawa Y; Ando S; Ishikawa Y; Itoi E J Orthop Sci; 2006 Oct; 11(5):454-8. PubMed ID: 17013732 [TBL] [Abstract][Full Text] [Related]
11. Cisterna magna arachnoid membrane suturing decreases incidence of pseudomeningocele formation and incisional CSF leakage. Pitskhelauri D; Kudieva E; Moshchev D; Ananev E; Shifrin M; Danilov G; Melnikova-Pitskhelauri T; Kachkov I; Bykanov A; Sanikidze A Acta Neurochir (Wien); 2018 May; 160(5):1079-1087. PubMed ID: 29557532 [TBL] [Abstract][Full Text] [Related]
12. The use of titanium non-penetrating clips to close the spinal dura. Timothy J; Hanna SJ; Furtado N; Shanmuganathan M; Tyagi A Br J Neurosurg; 2007 Jun; 21(3):268-71. PubMed ID: 17612916 [TBL] [Abstract][Full Text] [Related]
13. The Use of Cranial Aneurysm Clips for Repair of Incidental Lumbar Durotomy: Operative Technique and Case Series. Patel AA; Davison MA; Lilly D; Shost MD; Meade S; Habboub G; Krishnaney A World Neurosurg; 2024 Jul; 187():e707-e713. PubMed ID: 38692570 [TBL] [Abstract][Full Text] [Related]
14. Perioperative lumbar subarachnoid drainage could not prevent postoperative CSF leakage after spinal cord tumor resection using an artificial dura mater. Banno T; Hasegawa T; Yamato Y; Yoshida G; Arima H; Oe S; Mihara Y; Ide K; Watanabe Y; Kurosu K; Nakai K; Matsuyama Y J Orthop Sci; 2023 Jul; 28(4):745-751. PubMed ID: 35811252 [TBL] [Abstract][Full Text] [Related]
15. A new technique for dural suturing with fascia graft for cerebrospinal fluid leakage in transsphenoidal surgery. Ahn JY; Kim SH Neurosurgery; 2009 Dec; 65(6 Suppl):65-71; discussion 71-2. PubMed ID: 19935004 [TBL] [Abstract][Full Text] [Related]
16. Circumferential watertight dural repair using nitinol U-clips in expanded endonasal and sublabial approaches to the cranial base. Acerbi F; Genden E; Bederson J Neurosurgery; 2010 Dec; 67(2 Suppl Operative):448-56. PubMed ID: 21099571 [TBL] [Abstract][Full Text] [Related]
17. Hydrostatic comparison of nonpenetrating titanium clips versus conventional suture for repair of spinal durotomies. Faulkner ND; Finn MA; Anderson PA Spine (Phila Pa 1976); 2012 Apr; 37(9):E535-9. PubMed ID: 22322376 [TBL] [Abstract][Full Text] [Related]
18. Application of nonpenetrating titanium clips for primary spinal dural closure following intradural tethered cord release in pediatric tethered cord syndrome: Profile of safety, efficacy, efficiency, and complications. O'Neill BE; Godil JA; Brown NJ; Loya J; Silva A; Winer J World Neurosurg X; 2024 Apr; 22():100348. PubMed ID: 38440374 [TBL] [Abstract][Full Text] [Related]