233 related articles for article (PubMed ID: 30784784)
1. Effect of wear, acetabular cup inclination angle, load and serum degradation on the friction of a large diameter metal-on-metal hip prosthesis.
Saikko V
Clin Biomech (Bristol, Avon); 2019 Mar; 63():1-9. PubMed ID: 30784784
[TBL] [Abstract][Full Text] [Related]
2. Correlation of Cup Inclination Angle with Liner Wear for Metal-on-polyethylene in Hip Primary Arthroplasty.
Tian JL; Sun L; Hu RY; Han W; Tian XB
Orthop Surg; 2017 May; 9(2):186-190. PubMed ID: 28557297
[TBL] [Abstract][Full Text] [Related]
3. Which factors determine the wear rate of large-diameter metal-on-metal hip replacements? Multivariate analysis of two hundred and seventy-six components.
Hart AJ; Muirhead-Allwood S; Porter M; Matthies A; Ilo K; Maggiore P; Underwood R; Cann P; Cobb J; Skinner JA
J Bone Joint Surg Am; 2013 Apr; 95(8):678-85. PubMed ID: 23595065
[TBL] [Abstract][Full Text] [Related]
4. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.
Korduba LA; Essner A; Pivec R; Lancin P; Mont MA; Wang A; Delanois RE
Am J Orthop (Belle Mead NJ); 2014 Oct; 43(10):466-71. PubMed ID: 25303445
[TBL] [Abstract][Full Text] [Related]
5. The problem with large diameter metal-on-metal acetabular cup inclination.
Jeffers JR; Roques A; Taylor A; Tuke MA
Bull NYU Hosp Jt Dis; 2009; 67(2):189-92. PubMed ID: 19583552
[TBL] [Abstract][Full Text] [Related]
6. A tribological study of UHMWPE acetabular cups and polyurethane compliant layer acetabular cups.
Smith SL; Ash HE; Unsworth A
J Biomed Mater Res; 2000; 53(6):710-6. PubMed ID: 11074431
[TBL] [Abstract][Full Text] [Related]
7. A three-axis hip joint simulator for wear and friction studies on total hip prostheses.
Saikko VO
Proc Inst Mech Eng H; 1996; 210(3):175-85. PubMed ID: 8885654
[TBL] [Abstract][Full Text] [Related]
8. Influence of cup orientation on the wear performance of metal-on-metal hip replacements.
Angadji A; Royle M; Collins SN; Shelton JC
Proc Inst Mech Eng H; 2009 May; 223(4):449-57. PubMed ID: 19499835
[TBL] [Abstract][Full Text] [Related]
9. Taper Material Loss in Total Hip Replacements: Is It Affected by Joint Friction?
McCarty CP; Park SH; Ho NC; Sangiorgio SN; Ebramzadeh E
J Bone Joint Surg Am; 2022 May; 104(9):796-804. PubMed ID: 35167500
[TBL] [Abstract][Full Text] [Related]
10. Frictional heating of bearing materials tested in a hip joint wear simulator.
Lu Z; McKellop H
Proc Inst Mech Eng H; 1997; 211(1):101-8. PubMed ID: 9141895
[TBL] [Abstract][Full Text] [Related]
11. Friction measurement in a hip wear simulator.
Saikko V
Proc Inst Mech Eng H; 2016 May; 230(5):366-72. PubMed ID: 27160557
[TBL] [Abstract][Full Text] [Related]
12. Backside wear in acetabular hip joint replacement.
Braun S; Sonntag R; Schroeder S; Mueller U; Jaeger S; Gotterbarm T; Kretzer JP
Acta Biomater; 2019 Jan; 83():467-476. PubMed ID: 30408561
[TBL] [Abstract][Full Text] [Related]
13. The 2014 Frank Stinchfield Award: The 'landing zone' for wear and stability in total hip arthroplasty is smaller than we thought: a computational analysis.
Elkins JM; Callaghan JJ; Brown TD
Clin Orthop Relat Res; 2015 Feb; 473(2):441-52. PubMed ID: 25091222
[TBL] [Abstract][Full Text] [Related]
14. Potential thermal artifacts in hip joint wear simulators.
Lu Z; McKellop H; Liao P; Benya P
J Biomed Mater Res; 1999; 48(4):458-64. PubMed ID: 10421687
[TBL] [Abstract][Full Text] [Related]
15. Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position.
Williams S; Leslie I; Isaac G; Jin Z; Ingham E; Fisher J
J Bone Joint Surg Am; 2008 Aug; 90 Suppl 3():111-7. PubMed ID: 18676945
[TBL] [Abstract][Full Text] [Related]
16. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.
Williams S; Butterfield M; Stewart T; Ingham E; Stone M; Fisher J
Proc Inst Mech Eng H; 2003; 217(2):147-53. PubMed ID: 12666782
[TBL] [Abstract][Full Text] [Related]
17. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.
Goldsmith AA; Dowson D; Isaac GH; Lancaster JG
Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049
[TBL] [Abstract][Full Text] [Related]
18. The contribution of frictional torque to loosening at the cement-bone interface in Tharies hip replacements.
Mai MT; Schmalzried TP; Dorey FJ; Campbell PA; Amstutz HC
J Bone Joint Surg Am; 1996 Apr; 78(4):505-11. PubMed ID: 8609129
[TBL] [Abstract][Full Text] [Related]
19. Five Hundred Fifty-five Retrieved Metal-on-metal Hip Replacements of a Single Design Show a Wide Range of Wear, Surface Features, and Histopathologic Reactions.
Park SH; Lu Z; Hastings RS; Campbell PA; Ebramzadeh E
Clin Orthop Relat Res; 2018 Feb; 476(2):261-278. PubMed ID: 29529655
[TBL] [Abstract][Full Text] [Related]
20. Implant wear mechanisms--basic approach.
Bhatt H; Goswami T
Biomed Mater; 2008 Dec; 3(4):042001. PubMed ID: 18824778
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]