BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 30794510)

  • 1. A Krasnoselskii-Mann Algorithm With an Improved EM Preconditioner for PET Image Reconstruction.
    Lin Y; Schmidtlein CR; Li Q; Li S; Xu Y
    IEEE Trans Med Imaging; 2019 Sep; 38(9):2114-2126. PubMed ID: 30794510
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An ordered-subsets proximal preconditioned gradient algorithm for edge-preserving PET image reconstruction.
    Mehranian A; Rahmim A; Ay MR; Kotasidis F; Zaidi H
    Med Phys; 2013 May; 40(5):052503. PubMed ID: 23635293
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Relaxed ordered subset preconditioned alternating projection algorithm for PET reconstruction with automated penalty weight selection.
    Ross Schmidtlein C; Lin Y; Li S; Krol A; Beattie BJ; Humm JL; Xu Y
    Med Phys; 2017 Aug; 44(8):4083-4097. PubMed ID: 28437565
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Edge-preserving PET image reconstruction using trust optimization transfer.
    Wang G; Qi J
    IEEE Trans Med Imaging; 2015 Apr; 34(4):930-9. PubMed ID: 25438302
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Preconditioned Alternating Projection Algorithms for Maximum a Posteriori ECT Reconstruction.
    Krol A; Li S; Shen L; Xu Y
    Inverse Probl; 2012 Nov; 28(11):115005. PubMed ID: 23271835
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm.
    Li S; Zhang J; Krol A; Schmidtlein CR; Vogelsang L; Shen L; Lipson E; Feiglin D; Xu Y
    Med Phys; 2015 Aug; 42(8):4872-87. PubMed ID: 26233214
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Investigation of the preconditioner-parameter in the preconditioned Chambolle-Pock algorithm applied to optimization-based image reconstruction.
    Qiao Z; Redler G; Qian Y; Tang S; Epel B; Halpern H
    J Xray Sci Technol; 2018; 26(3):435-448. PubMed ID: 29562580
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Synergistic PET and SENSE MR Image Reconstruction Using Joint Sparsity Regularization.
    Mehranian A; Belzunce MA; Prieto C; Hammers A; Reader AJ
    IEEE Trans Med Imaging; 2018 Jan; 37(1):20-34. PubMed ID: 28436851
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Preconditioned alternating projection algorithm for solving the penalized-likelihood SPECT reconstruction problem.
    Li S; Zhang J; Krol A; Schmidtlein CR; Feiglin D; Xu Y
    Phys Med; 2017 Jun; 38():23-35. PubMed ID: 28610694
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A fast regularized iterative algorithm for fan-beam CT reconstruction.
    Wang T; Kudo H; Yamazaki F; Liu H
    Phys Med Biol; 2019 Jul; 64(14):145006. PubMed ID: 31108484
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Compressed sensing MRI via fast linearized preconditioned alternating direction method of multipliers.
    Chen S; Du H; Wu L; Jin J; Qiu B
    Biomed Eng Online; 2017 Apr; 16(1):53. PubMed ID: 28449672
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The performance of monotonic and new non-monotonic gradient ascent reconstruction algorithms for high-resolution neuroreceptor PET imaging.
    Angelis GI; Reader AJ; Kotasidis FA; Lionheart WR; Matthews JC
    Phys Med Biol; 2011 Jul; 56(13):3895-917. PubMed ID: 21654041
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Three penalized EM-type algorithms for PET image reconstruction.
    Teng Y; Zhang T
    Comput Biol Med; 2012 Jun; 42(6):714-23. PubMed ID: 22572466
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simultaneous estimation and segmentation from projection data in dynamic PET.
    Cui J; Yu H; Chen S; Chen Y; Liu H
    Med Phys; 2019 Mar; 46(3):1245-1259. PubMed ID: 30593666
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A regularized relaxed ordered subset list-mode reconstruction algorithm and its preliminary application to undersampling PET imaging.
    Cao X; Xie Q; Xiao P
    Phys Med Biol; 2015 Jan; 60(1):49-66. PubMed ID: 25478684
    [TBL] [Abstract][Full Text] [Related]  

  • 16. ADMM-EM Method for
    Teng Y; Sun H; Guo C; Kang Y
    Comput Math Methods Med; 2016; 2016():6458289. PubMed ID: 27840655
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accelerated fast iterative shrinkage thresholding algorithms for sparsity-regularized cone-beam CT image reconstruction.
    Xu Q; Yang D; Tan J; Sawatzky A; Anastasio MA
    Med Phys; 2016 Apr; 43(4):1849. PubMed ID: 27036582
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fast Quasi-Newton Algorithms for Penalized Reconstruction in Emission Tomography and Further Improvements via Preconditioning.
    Tsai YJ; Bousse A; Ehrhardt MJ; Stearns CW; Ahn S; Hutton BF; Arridge S; Thielemans K
    IEEE Trans Med Imaging; 2018 Apr; 37(4):1000-1010. PubMed ID: 29610077
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An optimization transfer algorithm for nonlinear parametric image reconstruction from dynamic PET data.
    Wang G; Qi J
    IEEE Trans Med Imaging; 2012 Oct; 31(10):1977-88. PubMed ID: 22893380
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A separable quadratic surrogate total variation minimization algorithm for accelerating accurate CT reconstruction from few-views and limited-angle data.
    Hou X; Teng Y; Kang Y; Qi S
    Med Phys; 2018 Feb; 45(2):535-548. PubMed ID: 29171030
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.