220 related articles for article (PubMed ID: 30798455)
1. Accuracy of ultrawide-field fundus ophthalmoscopy-assisted deep learning for detecting treatment-naïve proliferative diabetic retinopathy.
Nagasawa T; Tabuchi H; Masumoto H; Enno H; Niki M; Ohara Z; Yoshizumi Y; Ohsugi H; Mitamura Y
Int Ophthalmol; 2019 Oct; 39(10):2153-2159. PubMed ID: 30798455
[TBL] [Abstract][Full Text] [Related]
2. Accuracy of ultra-wide-field fundus ophthalmoscopy-assisted deep learning, a machine-learning technology, for detecting age-related macular degeneration.
Matsuba S; Tabuchi H; Ohsugi H; Enno H; Ishitobi N; Masumoto H; Kiuchi Y
Int Ophthalmol; 2019 Jun; 39(6):1269-1275. PubMed ID: 29744763
[TBL] [Abstract][Full Text] [Related]
3. Automatic Grading System for Diabetic Retinopathy Diagnosis Using Deep Learning Artificial Intelligence Software.
Wang XN; Dai L; Li ST; Kong HY; Sheng B; Wu Q
Curr Eye Res; 2020 Dec; 45(12):1550-1555. PubMed ID: 32410471
[No Abstract] [Full Text] [Related]
4. Artificial intelligence using deep learning to screen for referable and vision-threatening diabetic retinopathy in Africa: a clinical validation study.
Bellemo V; Lim ZW; Lim G; Nguyen QD; Xie Y; Yip MYT; Hamzah H; Ho J; Lee XQ; Hsu W; Lee ML; Musonda L; Chandran M; Chipalo-Mutati G; Muma M; Tan GSW; Sivaprasad S; Menon G; Wong TY; Ting DSW
Lancet Digit Health; 2019 May; 1(1):e35-e44. PubMed ID: 33323239
[TBL] [Abstract][Full Text] [Related]
5. Detection of Diabetic Retinopathy from Ultra-Widefield Scanning Laser Ophthalmoscope Images: A Multicenter Deep Learning Analysis.
Tang F; Luenam P; Ran AR; Quadeer AA; Raman R; Sen P; Khan R; Giridhar A; Haridas S; Iglicki M; Zur D; Loewenstein A; Negri HP; Szeto S; Lam BKY; Tham CC; Sivaprasad S; Mckay M; Cheung CY
Ophthalmol Retina; 2021 Nov; 5(11):1097-1106. PubMed ID: 33540169
[TBL] [Abstract][Full Text] [Related]
6. Referable diabetic retinopathy identification from eye fundus images with weighted path for convolutional neural network.
Liu YP; Li Z; Xu C; Li J; Liang R
Artif Intell Med; 2019 Aug; 99():101694. PubMed ID: 31606108
[TBL] [Abstract][Full Text] [Related]
7. Accuracy of deep learning, a machine-learning technology, using ultra-wide-field fundus ophthalmoscopy for detecting rhegmatogenous retinal detachment.
Ohsugi H; Tabuchi H; Enno H; Ishitobi N
Sci Rep; 2017 Aug; 7(1):9425. PubMed ID: 28842613
[TBL] [Abstract][Full Text] [Related]
8. Deep-learning classifier with ultrawide-field fundus ophthalmoscopy for detecting branch retinal vein occlusion.
Nagasato D; Tabuchi H; Ohsugi H; Masumoto H; Enno H; Ishitobi N; Sonobe T; Kameoka M; Niki M; Mitamura Y
Int J Ophthalmol; 2019; 12(1):94-99. PubMed ID: 30662847
[TBL] [Abstract][Full Text] [Related]
9. Deep Neural Network-Based Method for Detecting Central Retinal Vein Occlusion Using Ultrawide-Field Fundus Ophthalmoscopy.
Nagasato D; Tabuchi H; Ohsugi H; Masumoto H; Enno H; Ishitobi N; Sonobe T; Kameoka M; Niki M; Hayashi K; Mitamura Y
J Ophthalmol; 2018; 2018():1875431. PubMed ID: 30515316
[TBL] [Abstract][Full Text] [Related]
10. Computer-aided diagnosis of prostate cancer using a deep convolutional neural network from multiparametric MRI.
Song Y; Zhang YD; Yan X; Liu H; Zhou M; Hu B; Yang G
J Magn Reson Imaging; 2018 Dec; 48(6):1570-1577. PubMed ID: 29659067
[TBL] [Abstract][Full Text] [Related]
11. Development and Validation of a Deep Learning Algorithm for Detection of Diabetic Retinopathy in Retinal Fundus Photographs.
Gulshan V; Peng L; Coram M; Stumpe MC; Wu D; Narayanaswamy A; Venugopalan S; Widner K; Madams T; Cuadros J; Kim R; Raman R; Nelson PC; Mega JL; Webster DR
JAMA; 2016 Dec; 316(22):2402-2410. PubMed ID: 27898976
[TBL] [Abstract][Full Text] [Related]
12. Accuracy of Diabetic Retinopathy Staging with a Deep Convolutional Neural Network Using Ultra-Wide-Field Fundus Ophthalmoscopy and Optical Coherence Tomography Angiography.
Nagasawa T; Tabuchi H; Masumoto H; Morita S; Niki M; Ohara Z; Yoshizumi Y; Mitamura Y
J Ophthalmol; 2021; 2021():6651175. PubMed ID: 33884202
[TBL] [Abstract][Full Text] [Related]
13. Deep learning-based detection and classification of geographic atrophy using a deep convolutional neural network classifier.
Treder M; Lauermann JL; Eter N
Graefes Arch Clin Exp Ophthalmol; 2018 Nov; 256(11):2053-2060. PubMed ID: 30091055
[TBL] [Abstract][Full Text] [Related]
14. Application of deep learning image assessment software VeriSee™ for diabetic retinopathy screening.
Hsieh YT; Chuang LM; Jiang YD; Chang TJ; Yang CM; Yang CH; Chan LW; Kao TY; Chen TC; Lin HC; Tsai CH; Chen M
J Formos Med Assoc; 2021 Jan; 120(1 Pt 1):165-171. PubMed ID: 32307321
[TBL] [Abstract][Full Text] [Related]
15. Improved Automated Detection of Diabetic Retinopathy on a Publicly Available Dataset Through Integration of Deep Learning.
Abràmoff MD; Lou Y; Erginay A; Clarida W; Amelon R; Folk JC; Niemeijer M
Invest Ophthalmol Vis Sci; 2016 Oct; 57(13):5200-5206. PubMed ID: 27701631
[TBL] [Abstract][Full Text] [Related]
16. The sensitivity and specificity of single-field nonmydriatic monochromatic digital fundus photography with remote image interpretation for diabetic retinopathy screening: a comparison with ophthalmoscopy and standardized mydriatic color photography.
Lin DY; Blumenkranz MS; Brothers RJ; Grosvenor DM
Am J Ophthalmol; 2002 Aug; 134(2):204-13. PubMed ID: 12140027
[TBL] [Abstract][Full Text] [Related]
17. Accuracy of deep learning, a machine learning technology, using ultra-wide-field fundus ophthalmoscopy for detecting idiopathic macular holes.
Nagasawa T; Tabuchi H; Masumoto H; Enno H; Niki M; Ohsugi H; Mitamura Y
PeerJ; 2018; 6():e5696. PubMed ID: 30370184
[TBL] [Abstract][Full Text] [Related]
18. Neovascularization Detection and Localization in Fundus Images Using Deep Learning.
Tang MCS; Teoh SS; Ibrahim H; Embong Z
Sensors (Basel); 2021 Aug; 21(16):. PubMed ID: 34450766
[TBL] [Abstract][Full Text] [Related]
19. Using a Deep Learning Algorithm and Integrated Gradients Explanation to Assist Grading for Diabetic Retinopathy.
Sayres R; Taly A; Rahimy E; Blumer K; Coz D; Hammel N; Krause J; Narayanaswamy A; Rastegar Z; Wu D; Xu S; Barb S; Joseph A; Shumski M; Smith J; Sood AB; Corrado GS; Peng L; Webster DR
Ophthalmology; 2019 Apr; 126(4):552-564. PubMed ID: 30553900
[TBL] [Abstract][Full Text] [Related]
20. Diagnostic accuracy of non-mydriatic fundus camera for screening of diabetic retinopathy: A hospital based observational study in Pakistan.
Fahadullah M; Memon NA; Salim S; Ahsan S; Fahim MF; Mumtaz SN; Shaikh SA; Memon MS
J Pak Med Assoc; 2019 Mar; 69(3):378-382. PubMed ID: 30890831
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]