153 related articles for article (PubMed ID: 30800509)
1. Simultaneous dual-band line-field confocal optical coherence tomography: application to skin imaging.
Davis A; Levecq O; Azimani H; Siret D; Dubois A
Biomed Opt Express; 2019 Feb; 10(2):694-706. PubMed ID: 30800509
[TBL] [Abstract][Full Text] [Related]
2. Simultaneous dual-band optical coherence tomography in the spectral domain for high resolution in vivo imaging.
Cimalla P; Walther J; Mehner M; Cuevas M; Koch E
Opt Express; 2009 Oct; 17(22):19486-500. PubMed ID: 19997169
[TBL] [Abstract][Full Text] [Related]
3. Mirau-based line-field confocal optical coherence tomography for three-dimensional high-resolution skin imaging.
Xue W; Ogien J; Bulkin P; Coutrot AL; Dubois A
J Biomed Opt; 2022 Aug; 27(8):. PubMed ID: 35962466
[TBL] [Abstract][Full Text] [Related]
4. Dual-mode line-field confocal optical coherence tomography for ultrahigh-resolution vertical and horizontal section imaging of human skin
Ogien J; Levecq O; Azimani H; Dubois A
Biomed Opt Express; 2020 Mar; 11(3):1327-1335. PubMed ID: 32206413
[TBL] [Abstract][Full Text] [Related]
5. Line-field confocal time-domain optical coherence tomography with dynamic focusing.
Dubois A; Levecq O; Azimani H; Davis A; Ogien J; Siret D; Barut A
Opt Express; 2018 Dec; 26(26):33534-33542. PubMed ID: 30650800
[TBL] [Abstract][Full Text] [Related]
6. Mirau-based line-field confocal optical coherence tomography.
Dubois A; Xue W; Levecq O; Bulkin P; Coutrot AL; Ogien J
Opt Express; 2020 Mar; 28(6):7918-7927. PubMed ID: 32225427
[TBL] [Abstract][Full Text] [Related]
7. Line-field confocal optical coherence tomography for high-resolution noninvasive imaging of skin tumors.
Dubois A; Levecq O; Azimani H; Siret D; Barut A; Suppa M; Del Marmol V; Malvehy J; Cinotti E; Rubegni P; Perrot JL
J Biomed Opt; 2018 Oct; 23(10):1-9. PubMed ID: 30353716
[TBL] [Abstract][Full Text] [Related]
8. Simultaneous dual-band ultra-high resolution full-field optical coherence tomography.
Sacchet D; Moreau J; Georges P; Dubois A
Opt Express; 2008 Nov; 16(24):19434-46. PubMed ID: 19030031
[TBL] [Abstract][Full Text] [Related]
9. Line-field confocal optical coherence tomography for three-dimensional skin imaging.
Ogien J; Daures A; Cazalas M; Perrot JL; Dubois A
Front Optoelectron; 2020 Dec; 13(4):381-392. PubMed ID: 36641566
[TBL] [Abstract][Full Text] [Related]
10. Simultaneous dual-band ultra-high resolution optical coherence tomography.
Spöler F; Kray S; Grychtol P; Hermes B; Bornemann J; Först M; Kurz H
Opt Express; 2007 Aug; 15(17):10832-41. PubMed ID: 19547440
[TBL] [Abstract][Full Text] [Related]
11. Real-time fiber-based multi-functional spectral-domain optical coherence tomography at 1.3 microm.
Park B; Pierce MC; Cense B; Yun SH; Mujat M; Tearney G; Bouma B; de Boer J
Opt Express; 2005 May; 13(11):3931-44. PubMed ID: 19495302
[TBL] [Abstract][Full Text] [Related]
12. Fourier domain optical coherence tomography using optical demultiplexers imaging at 60,000,000 lines/s.
Choi D; Hiro-Oka H; Furukawa H; Yoshimura R; Nakanishi M; Shimizu K; Ohbayashi K
Opt Lett; 2008 Jun; 33(12):1318-20. PubMed ID: 18552944
[TBL] [Abstract][Full Text] [Related]
13. High-speed spectral-domain optical coherence tomography at 1.3 mum wavelength.
Yun S; Tearney G; Bouma B; Park B; de Boer J
Opt Express; 2003 Dec; 11(26):3598-604. PubMed ID: 19471496
[TBL] [Abstract][Full Text] [Related]
14. Ultrahigh resolution spectral-domain optical coherence tomography using the 1000-1600 nm spectral band.
Bernstein L; Ramier A; Wu J; Aiello VD; Béland MJ; Lin CP; Yun SH
Biomed Opt Express; 2022 Apr; 13(4):1939-1947. PubMed ID: 35519264
[TBL] [Abstract][Full Text] [Related]
15. High-spatial-resolution deep tissue imaging with spectral-domain optical coherence microscopy in the 1700-nm spectral band.
Yamanaka M; Hayakawa N; Nishizawa N
J Biomed Opt; 2019 Jul; 24(7):1-4. PubMed ID: 31364330
[TBL] [Abstract][Full Text] [Related]
16. Dual-band infrared optical coherence tomography using a single supercontinuum source.
Zorin I; Gattinger P; Brandstetter M; Heise B
Opt Express; 2020 Mar; 28(6):7858-7874. PubMed ID: 32225421
[TBL] [Abstract][Full Text] [Related]
17. Optical coherence microscopy in 1700 nm spectral band for high-resolution label-free deep-tissue imaging.
Yamanaka M; Teranishi T; Kawagoe H; Nishizawa N
Sci Rep; 2016 Aug; 6():31715. PubMed ID: 27546517
[TBL] [Abstract][Full Text] [Related]
18. Three-band, 1.9-μm axial resolution full-field optical coherence microscopy over a 530-1700 nm wavelength range using a single camera.
Federici A; Dubois A
Opt Lett; 2014 Mar; 39(6):1374-7. PubMed ID: 24690791
[TBL] [Abstract][Full Text] [Related]
19. Dual band dual focus optical coherence tomography for imaging the whole eye segment.
Fan S; Li L; Li Q; Dai C; Ren Q; Jiao S; Zhou C
Biomed Opt Express; 2015 Jul; 6(7):2481-93. PubMed ID: 26203375
[TBL] [Abstract][Full Text] [Related]
20. Simultaneous dual-wavelength-band common-path swept-source optical coherence tomography with single polygon mirror scanner.
Mao Y; Chang S; Murdock E; Flueraru C
Opt Lett; 2011 Jun; 36(11):1990-2. PubMed ID: 21633425
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]