337 related articles for article (PubMed ID: 30805874)
1. Experimental Insight into the Hemodynamics and Perfusion of Radiological Contrast in Patent and Non-patent Aortic Dissection Models.
Salameh E; Saade C; Oweis GF
Cardiovasc Eng Technol; 2019 Jun; 10(2):314-328. PubMed ID: 30805874
[TBL] [Abstract][Full Text] [Related]
2. An in vitro phantom study on the influence of tear size and configuration on the hemodynamics of the lumina in chronic type B aortic dissections.
Rudenick PA; Bijnens BH; García-Dorado D; Evangelista A
J Vasc Surg; 2013 Feb; 57(2):464-474.e5. PubMed ID: 23141674
[TBL] [Abstract][Full Text] [Related]
3. Computational Study of Anatomical Risk Factors in Idealized Models of Type B Aortic Dissection.
Ben Ahmed S; Dillon-Murphy D; Figueroa CA
Eur J Vasc Endovasc Surg; 2016 Dec; 52(6):736-745. PubMed ID: 27561609
[TBL] [Abstract][Full Text] [Related]
4. The risk of stanford type-A aortic dissection with different tear size and location: a numerical study.
Shi Y; Zhu M; Chang Y; Qiao H; Liu Y
Biomed Eng Online; 2016 Dec; 15(Suppl 2):128. PubMed ID: 28155679
[TBL] [Abstract][Full Text] [Related]
5. Initial findings and potential applicability of computational simulation of the aorta in acute type B dissection.
Cheng Z; Riga C; Chan J; Hamady M; Wood NB; Cheshire NJ; Xu Y; Gibbs RG
J Vasc Surg; 2013 Feb; 57(2 Suppl):35S-43S. PubMed ID: 23336853
[TBL] [Abstract][Full Text] [Related]
6. Three-dimensional modelling and hemodynamic simulation of the closure of multiple entry tears in type B aortic dissection.
Liu H; Zhao G; Zhang GE; Xiong F; Hu S; Ouyang Y; Xiong F
Med Phys; 2024 Jan; 51(1):42-53. PubMed ID: 38038366
[TBL] [Abstract][Full Text] [Related]
7. The Role of Multiple Re-Entry Tears in Type B Aortic Dissection Progression: A Longitudinal Study Using a Controlled Swine Model.
Armour C; Guo B; Saitta S; Guo D; Liu Y; Fu W; Dong Z; Xu XY
J Endovasc Ther; 2024 Feb; 31(1):104-114. PubMed ID: 35852439
[TBL] [Abstract][Full Text] [Related]
8. Correlation between hemodynamic parameters and intra-arterial septum motion in DeBakey Type III aortic dissections using 2D pcMRI and 4D MRA.
Karmonik C; Duran C; Davies MG; Shah DJ; Lumsden AB; Bismuth J
Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():2809-12. PubMed ID: 22254925
[TBL] [Abstract][Full Text] [Related]
9. Editor's Choice - Fluid-Structure Interaction Simulations of Aortic Dissection with Bench Validation.
Chen HY; Peelukhana SV; Berwick ZC; Kratzberg J; Krieger JF; Roeder B; Chambers S; Kassab GS
Eur J Vasc Endovasc Surg; 2016 Nov; 52(5):589-595. PubMed ID: 27601219
[TBL] [Abstract][Full Text] [Related]
10. The Impact of Intimal Tear Location and Partial False Lumen Thrombosis in Acute Type B Aortic Dissection.
Girish A; Padala M; Kalra K; McIver BV; Veeraswamy RK; Chen EP; Leshnower BG
Ann Thorac Surg; 2016 Dec; 102(6):1925-1932. PubMed ID: 27424468
[TBL] [Abstract][Full Text] [Related]
11. Multi-modality image-based computational analysis of haemodynamics in aortic dissection.
Dillon-Murphy D; Noorani A; Nordsletten D; Figueroa CA
Biomech Model Mechanobiol; 2016 Aug; 15(4):857-76. PubMed ID: 26416312
[TBL] [Abstract][Full Text] [Related]
12. Endograft exclusion of the false lumen restores local hemodynamics in a model of type B aortic dissection.
Birjiniuk J; Oshinski JN; Ku DN; Veeraswamy RK
J Vasc Surg; 2020 Jun; 71(6):2108-2118. PubMed ID: 32446515
[TBL] [Abstract][Full Text] [Related]
13. Elevated Wall Shear Stress in Aortic Type B Dissection May Relate to Retrograde Aortic Type A Dissection: A Computational Fluid Dynamics Pilot Study.
Osswald A; Karmonik C; Anderson JR; Rengier F; Karck M; Engelke J; Kallenbach K; Kotelis D; Partovi S; Böckler D; Ruhparwar A
Eur J Vasc Endovasc Surg; 2017 Sep; 54(3):324-330. PubMed ID: 28716447
[TBL] [Abstract][Full Text] [Related]
14. New classification of aortic dissection during the cardiac cycle as pulsating type and static type evaluated by electrocardiogram-gated multislice CT.
Murayama T; Funabashi N; Uehara M; Takaoka H; Komuro I
Int J Cardiol; 2010 Jul; 142(2):177-86. PubMed ID: 19193460
[TBL] [Abstract][Full Text] [Related]
15. Computational fluid dynamics investigation of chronic aortic dissection hemodynamics versus normal aorta.
Karmonik C; Müller-Eschner M; Partovi S; Geisbüsch P; Ganten MK; Bismuth J; Davies MG; Böckler D; Loebe M; Lumsden AB; von Tengg-Kobligk H
Vasc Endovascular Surg; 2013 Nov; 47(8):625-31. PubMed ID: 24048257
[TBL] [Abstract][Full Text] [Related]
16. Wall Shear Stress Assessment of the False Lumen in Acute Type B Aortic Dissection Visualized by 4-Dimensional Flow Magnetic Resonance Imaging: An Ex-Vivo Study.
Veger HTC; Pasveer EH; Westenberg JJM; Wever JJ; van Eps RGS
Vasc Endovascular Surg; 2021 Oct; 55(7):696-701. PubMed ID: 34078199
[TBL] [Abstract][Full Text] [Related]
17. False lumen enhancement characteristics on computed tomography angiography predict risk of aneurysm formation in acute type B aortic dissection.
Roseland ME; Ahmed Y; van Herwaarden JA; Moll FL; Yang B; Patel HJ; Burris NS
Interact Cardiovasc Thorac Surg; 2021 Aug; 33(3):434-441. PubMed ID: 33963411
[TBL] [Abstract][Full Text] [Related]
18. Aortic dissection: the flood tide sign.
Rossi UG; Seitun S; Cariati M
J Cardiovasc Comput Tomogr; 2013; 7(5):330-2. PubMed ID: 24268122
[TBL] [Abstract][Full Text] [Related]
19. Multilayer flow modulator enhances vital organ perfusion in patients with type B aortic dissection.
Rikhtegar Nezami F; Athanasiou LS; Amrute JM; Edelman ER
Am J Physiol Heart Circ Physiol; 2018 Nov; 315(5):H1182-H1193. PubMed ID: 30095992
[TBL] [Abstract][Full Text] [Related]
20. False Lumen Flow Patterns and their Relation with Morphological and Biomechanical Characteristics of Chronic Aortic Dissections. Computational Model Compared with Magnetic Resonance Imaging Measurements.
Rudenick PA; Segers P; Pineda V; Cuellar H; García-Dorado D; Evangelista A; Bijnens BH
PLoS One; 2017; 12(1):e0170888. PubMed ID: 28125720
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]