  • 1. Are Serum Metal Ion Levels a Concern at Mid-term Followup of Revision Knee Arthroplasty With a Metal-on-metal Hinge Design?
    Klasan A; Meine E; Fuchs-Winkelmann S; Efe T; Boettner F; Heyse TJ
    Clin Orthop Relat Res; 2019 Sep; 477(9):2007-2014. PubMed ID: 30811355
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Critically high metal ion levels found in metal-on-metal modular hinged knee arthroplasty : a comparison of two different systems.
    Gramlich Y; Hofmann L; Kress S; Ruckes C; Kemmerer M; Klug A; Hoffmann R; Kremer M
    Bone Joint J; 2022 Mar; 104-B(3):376-385. PubMed ID: 35227095
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements.
    Laitinen M; Nieminen J; Reito A; Pakarinen TK; Suomalainen P; Pamilo K; Parkkinen J; Lont T; Eskelinen A
    Acta Orthop; 2017 Jun; 88(3):269-274. PubMed ID: 28122467
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Adverse Local Tissue Reactions are Common in Asymptomatic Individuals After Hip Resurfacing Arthroplasty: Interim Report from a Prospective Longitudinal Study.
    Koff MF; Gao MA; Neri JP; Chiu YF; Lin BQ; Burge AJ; Su E; Padgett DE; Potter HG
    Clin Orthop Relat Res; 2021 Dec; 479(12):2633-2650. PubMed ID: 34232144
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Revisions of Modular Metal-on-metal THA Have a High Risk of Early Complications.
    Jennings JM; White S; Martin JR; Yang CC; Miner TM; Dennis DA
    Clin Orthop Relat Res; 2019 Feb; 477(2):344-350. PubMed ID: 30794222
    [TBL] [Abstract][Full Text] [Related]  

  • 6. No Difference in Reoperations at 2 Years Between Ceramic-on-metal and Metal-on-metal THA: A Randomized Trial.
    Engh CA; Sritulanondha S; Korczak A; Whalen TD; Naudie DD; McCalden RW; MacDonald SJ
    Clin Orthop Relat Res; 2016 Feb; 474(2):447-55. PubMed ID: 26135473
    [TBL] [Abstract][Full Text] [Related]  

  • 7. What Is the Clinical Presentation of Adverse Local Tissue Reaction in Metal-on-metal Hip Arthroplasty? An MRI Study.
    Galea VP; Laaksonen I; Connelly JW; Matuszak SJ; Nortje M; Madanat R; Muratoglu O; Malchau H
    Clin Orthop Relat Res; 2019 Feb; 477(2):353-360. PubMed ID: 30794223
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Revision of Metal-on-metal Hip Prostheses Results in Marked Reduction of Blood Cobalt and Chromium Ion Concentrations.
    Lainiala O; Reito A; Elo P; Pajamäki J; Puolakka T; Eskelinen A
    Clin Orthop Relat Res; 2015 Jul; 473(7):2305-13. PubMed ID: 25623595
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mid-term changes in blood metal ion levels after Articular Surface Replacement arthroplasty of the hip.
    Galea VP; Laaksonen I; Matuszak SJ; Connelly JW; Muratoglu O; Malchau H
    Bone Joint J; 2017 Apr; 99-B(4 Supple B):33-40. PubMed ID: 28363892
    [TBL] [Abstract][Full Text] [Related]  

  • 10. What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA?
    Bayley N; Khan H; Grosso P; Hupel T; Stevens D; Snider M; Schemitsch E; Kuzyk P
    Clin Orthop Relat Res; 2015 Feb; 473(2):477-84. PubMed ID: 25085361
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Diagnostic Utility of Serum Metal Ion Markers for High-Grade Aseptic Lymphocyte-Dominated Vasculitis-Associated Lesions (ALVALs) in Revision Hip and Knee Arthroplasty: An International Multicenter Study.
    Sheridan GA; Neufeld ME; Sidhu A; Kurmis AP; Kelly M; O'Byrne JM; Howard LC; Masri BA; Garbuz DS
    J Arthroplasty; 2024 Jan; 39(1):206-210. PubMed ID: 37331438
    [TBL] [Abstract][Full Text] [Related]  

  • 12. What Is the Natural History of Asymptomatic Pseudotumors in Metal-on-metal THAs at Mid-term Followup?
    Konan S; Duncan CP; Masri BS; Garbuz DS
    Clin Orthop Relat Res; 2017 Feb; 475(2):433-441. PubMed ID: 27444034
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Do ion levels in metal-on-metal hip resurfacing differ from those in metal-on-metal THA at long-term followup?
    Savarino L; Cadossi M; Chiarello E; Baldini N; Giannini S
    Clin Orthop Relat Res; 2013 Sep; 471(9):2964-71. PubMed ID: 23572350
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Metal-on-Metal Total Hip Resurfacing Arthroplasty: An Evidence-Based Analysis.
    Medical Advisory Secretariat
    Ont Health Technol Assess Ser; 2006; 6(4):1-57. PubMed ID: 23074495
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High Revision Rate for Large-head Metal-on-metal THA at a Mean of 7.1 Years: A Registry Study.
    Seppänen M; Laaksonen I; Pulkkinen P; Eskelinen A; Puhto AP; Kettunen J; Leskinen J; Manninen M; Mäkelä K
    Clin Orthop Relat Res; 2018 Jun; 476(6):1223-1230. PubMed ID: 29480891
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Predictive factors for metal ion levels in metal-on-metal total hip arthroplasty.
    Kasparek MF; Renner L; Faschingbauer M; Waldstein W; Weber M; Boettner F
    Arch Orthop Trauma Surg; 2018 Feb; 138(2):281-286. PubMed ID: 29260384
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cobalt serum levels differ in well functioning Birmingham resurfacing and Birmingham modular THA.
    Renner L; Faschingbauer M; Schmidt-Braekling T; Boettner F
    Arch Orthop Trauma Surg; 2016 May; 136(5):715-21. PubMed ID: 26983720
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Blood Metal Ion Thresholds to Identify Patients with Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris: An External Multicenter Validation Study of Birmingham Hip Resurfacing and Corail-Pinnacle Implants.
    Matharu GS; Berryman F; Judge A; Reito A; McConnell J; Lainiala O; Young S; Eskelinen A; Pandit HG; Murray DW
    J Bone Joint Surg Am; 2017 Sep; 99(18):1532-1539. PubMed ID: 28926382
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Two-year serum metal ion levels in minimally invasive total conservative hip resurfacing: preliminary results of a prospective study.
    Tai SM; Millard N; Munir S; Jenabzadeh AR; Walter LR; Walter WL
    ANZ J Surg; 2015 Mar; 85(3):164-8. PubMed ID: 25288230
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Changes in blood ion levels after removal of metal-on-metal hip replacements: 16 patients followed for 0-12 months.
    Durrani SK; Noble PC; Sampson B; Panetta T; Liddle AD; Sabah SA; Chan NK; Skinner JA; Hart AJ
    Acta Orthop; 2014 Jun; 85(3):259-65. PubMed ID: 24758321
    [TBL] [Abstract][Full Text] [Related]  