These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

262 related articles for article (PubMed ID: 30838102)

  • 1. Biomechanical Evaluation of Internal Fixation of Pauwels Type III Femoral Neck Fractures: A Systematic Review of Various Fixation Methods.
    Cha YH; Yoo JI; Hwang SY; Kim KJ; Kim HY; Choy WS; Hwang SC
    Clin Orthop Surg; 2019 Mar; 11(1):1-14. PubMed ID: 30838102
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical evaluation of different internal fixation methods based on finite element analysis for Pauwels type III femoral neck fracture.
    Jiang X; Liang K; Du G; Chen Y; Tang Y; Geng K
    Injury; 2022 Oct; 53(10):3115-3123. PubMed ID: 35999063
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite Element Analysis of Six Internal Fixations in the Treatment of Pauwels Type III Femoral Neck Fracture.
    Sun X; Han Z; Cao D; Han C; Xie M; Zeng X; Dong Q
    Orthop Surg; 2024 Jul; 16(7):1695-1709. PubMed ID: 38747083
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical study on parallel cannulated compression screw combined with medial buttress plate fixation and F-type cannulated compression screw fixation in Pauwels III femoral neck fracture:A finite element analysis.
    Wang J; Gao Y; Song D; Ni J
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2022 Aug; 47(8):1143-1153. PubMed ID: 36097783
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical analysis of various internal fracture fixation devices used for treating femoral neck fractures: A comparative finite element analysis.
    Mahapatra B; Pal B
    Injury; 2024 Oct; 55(10):111717. PubMed ID: 39002322
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: A biomechanical study.
    Zhou L; Lin J; Huang A; Gan W; Zhai X; Sun K; Huang S; Li Z
    Clin Biomech (Bristol); 2020 Apr; 74():103-110. PubMed ID: 32155446
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparative biomechanical analysis of fixation devices for unstable femoral neck fractures: the Intertan versus cannulated screws or a dynamic hip screw.
    Rupprecht M; Grossterlinden L; Ruecker AH; de Oliveira AN; Sellenschloh K; Nüchtern J; Püschel K; Morlock M; Rueger JM; Lehmann W
    J Trauma; 2011 Sep; 71(3):625-34. PubMed ID: 21768904
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures.
    Ma J; Zhao Z; Zhi X; Wang H; Wang W
    BMC Musculoskelet Disord; 2022 Nov; 23(1):1030. PubMed ID: 36447275
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison with the Dynamic Hip Screw and Cannulated Screws.
    Stoffel K; Zderic I; Gras F; Sommer C; Eberli U; Mueller D; Oswald M; Gueorguiev B
    J Orthop Trauma; 2017 Mar; 31(3):131-137. PubMed ID: 27755333
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation.
    Knobe M; Altgassen S; Maier KJ; Gradl-Dietsch G; Kaczmarek C; Nebelung S; Klos K; Kim BS; Gueorguiev B; Horst K; Buecking B
    Int Orthop; 2018 Feb; 42(2):409-418. PubMed ID: 28780597
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical comparison of four different fixation methods in the management of Pauwels type III femoral neck fractures: Is there a clear winner?
    Yildirim C; Demirel M; Karahan G; Cetinkaya E; Misir A; Yamak F; Bozdağ E
    Injury; 2022 Oct; 53(10):3124-3129. PubMed ID: 35803747
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Gamma Nail Combined with One Cannulated Compression Screw Fixation for Treating Pauwels Type III Femoral Neck Fractures in Young and Middle-Aged Adults: Clinical Follow-Up and Biomechanical Studies.
    Wen Q; Gu F; Su Z; Zhang K; Xie X; Li J; Sui Z; Yu T
    Orthop Surg; 2023 Apr; 15(4):1045-1052. PubMed ID: 36846936
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Internal fixation of femoral neck fractures with posterior comminution: a biomechanical comparison of DHS® and Intertan nail®.
    Rupprecht M; Grossterlinden L; Sellenschloh K; Hoffmann M; Püschel K; Morlock M; Rueger JM; Lehmann W
    Int Orthop; 2011 Nov; 35(11):1695-701. PubMed ID: 21286918
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical evaluation of internal fixation implants for femoral neck fractures: A comparative finite element analysis.
    Zeng W; Liu Y; Hou X
    Comput Methods Programs Biomed; 2020 Nov; 196():105714. PubMed ID: 32858283
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture.
    Wang Z; Yang Y; Feng G; Guo H; Chen Z; Chen Y; Jin Q
    Biomed Eng Online; 2022 Jun; 21(1):34. PubMed ID: 35689282
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical effects of internal fixation with self-lock compression anti-rotation blade for Pauwels type III femoral neck fractures: a comparative finite element analysis.
    Huang BX; Zhan SZ; Yang M; Zhang DY
    BMC Musculoskelet Disord; 2023 Apr; 24(1):292. PubMed ID: 37059976
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical properties of off-axis screw in Pauwels III femoral neck fracture fixation: Bicortical screw construct is superior to unicortical screw construct.
    Kuan FC; Hsu KL; Lin CL; Hong CK; Yeh ML; Su WR
    Injury; 2019 Nov; 50(11):1889-1894. PubMed ID: 31431332
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture.
    Tianye L; Peng Y; Jingli X; QiuShi W; GuangQuan Z; Wei H; Qingwen Z
    Biomed Pharmacother; 2019 Apr; 112():108658. PubMed ID: 30970508
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Efficacy comparison between dynamic hip screw combined with anti-rotation screw and cannulated screw in treating femoral neck fractures].
    Chen Z; Wang G; Lin J; Yang T; Fang Y; Liu L; Zhang H
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Jan; 25(1):26-9. PubMed ID: 21351604
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative finite element analysis of four different internal fixation implants for Pauwels type III femoral neck fractures in various fracture angles in the sagittal plane.
    Özer A; Öner K; Okutan AE; Ayas MS
    Jt Dis Relat Surg; 2022; 33(2):352-358. PubMed ID: 35852194
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.