122 related articles for article (PubMed ID: 30840714)
1. Signal template generation from acquired images for model observer-based image quality analysis in mammography.
Balta C; Bouwman RW; Veldkamp WJH; Broeders MJM; Sechopoulos I; van Engen RE
J Med Imaging (Bellingham); 2018 Jul; 5(3):035503. PubMed ID: 30840714
[TBL] [Abstract][Full Text] [Related]
2. Toward image quality assessment in mammography using model observers: Detection of a calcification-like object.
Bouwman RW; Mackenzie A; van Engen RE; Broeders MJM; Young KC; Dance DR; den Heeten GJ; Veldkamp WJH
Med Phys; 2017 Nov; 44(11):5726-5739. PubMed ID: 28837225
[TBL] [Abstract][Full Text] [Related]
3. Can a channelized Hotelling observer assess image quality in acquired mammographic images of an anthropomorphic breast phantom including image processing?
Balta C; Bouwman RW; Sechopoulos I; Broeders MJM; Karssemeijer N; van Engen RE; Veldkamp WJH
Med Phys; 2019 Feb; 46(2):714-725. PubMed ID: 30561108
[TBL] [Abstract][Full Text] [Related]
4. A model observer study using acquired mammographic images of an anthropomorphic breast phantom.
Balta C; Bouwman RW; Sechopoulos I; Broeders MJM; Karssemeijer N; van Engen RE; Veldkamp WJH
Med Phys; 2018 Feb; 45(2):655-665. PubMed ID: 29193129
[TBL] [Abstract][Full Text] [Related]
5. A performance comparison of anthropomorphic model observers for breast cone beam CT images: A single-slice and multislice study.
Han M; Baek J
Med Phys; 2019 Aug; 46(8):3431-3441. PubMed ID: 31106432
[TBL] [Abstract][Full Text] [Related]
6. The regression detectability index RDI for mammography images of breast phantoms with calcification-like objects and anatomical background.
Anton M; Reginatto M; Elster C; Mäder U; Schopphoven S; Sechopoulos I; van Engen R
Phys Med Biol; 2021 Nov; 66(22):. PubMed ID: 34706354
[TBL] [Abstract][Full Text] [Related]
7. Can the channelized Hotelling observer including aspects of the human visual system predict human observer performance in mammography?
Bouwman RW; Goffi M; van Engen RE; Broeders MJ; Dance DR; Young KC; Veldkamp WJ
Phys Med; 2017 Jan; 33():95-105. PubMed ID: 28040401
[TBL] [Abstract][Full Text] [Related]
8. Visual-search observers for assessing tomographic x-ray image quality.
Gifford HC; Liang Z; Das M
Med Phys; 2016 Mar; 43(3):1563-75. PubMed ID: 26936739
[TBL] [Abstract][Full Text] [Related]
9. Optimization of the difference-of-Gaussian channel sets for the channelized Hotelling observer.
Balta C; Bouwman RW; Broeders MJM; Karssemeijer N; Veldkamp WJH; Sechopoulos I; van Engen RE
J Med Imaging (Bellingham); 2019 Jul; 6(3):035501. PubMed ID: 31572746
[TBL] [Abstract][Full Text] [Related]
10. Channelized Hotelling observer correlation with human observers for low-contrast detection in liver CT images.
Ba A; Abbey CK; Racine D; Viry A; Verdun FR; Schmidt S; Bochud FO
J Med Imaging (Bellingham); 2019 Apr; 6(2):025501. PubMed ID: 31131292
[TBL] [Abstract][Full Text] [Related]
11. Adaptation of a channelized Hotelling observer model to accommodate anthropomorphic backgrounds and moving test objects in X-ray angiography.
Gomez-Cardona D; Favazza CP; Leng S; Schueler BA; Fetterly KA
Med Phys; 2023 Nov; 50(11):6737-6747. PubMed ID: 37712881
[TBL] [Abstract][Full Text] [Related]
12. Comparison of signal to noise ratios from spatial and frequency domain formulations of nonprewhitening model observers in digital mammography.
Sisini F; Zanca F; Marshall NW; Taibi A; Cardarelli P; Bosmans H
Med Phys; 2012 Sep; 39(9):5652-63. PubMed ID: 22957631
[TBL] [Abstract][Full Text] [Related]
13. Effects of exposure equalization on image signal-to-noise ratios in digital mammography: a simulation study with an anthropomorphic breast phantom.
Liu X; Lai CJ; Whitman GJ; Geiser WR; Shen Y; Yi Y; Shaw CC
Med Phys; 2011 Dec; 38(12):6489-501. PubMed ID: 22149832
[TBL] [Abstract][Full Text] [Related]
14. Derivation of an Observer Model Adapted to Irregular Signals Based on Convolution Channels.
Diaz I; Abbey CK; Timberg PAS; Eckstein MP; Verdun FR; Castella C; Bochud FO
IEEE Trans Med Imaging; 2015 Jul; 34(7):1428-1435. PubMed ID: 25622313
[TBL] [Abstract][Full Text] [Related]
15. Correlation between a 2D channelized Hotelling observer and human observers in a low-contrast detection task with multislice reading in CT.
Yu L; Chen B; Kofler JM; Favazza CP; Leng S; Kupinski MA; McCollough CH
Med Phys; 2017 Aug; 44(8):3990-3999. PubMed ID: 28555878
[TBL] [Abstract][Full Text] [Related]
16. Can the non-pre-whitening model observer, including aspects of the human visual system, predict human observer performance in mammography?
Bouwman RW; van Engen RE; Broeders MJ; den Heeten GJ; Dance DR; Young KC; Veldkamp WJ
Phys Med; 2016 Dec; 32(12):1559-1569. PubMed ID: 27889130
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of clinical full field digital mammography with the task specific system-model-based Fourier Hotelling observer (SMFHO) SNR.
Liu H; Chakrabarti K; Kaczmarek RV; Benevides L; Gu S; Kyprianou IS
Med Phys; 2014 May; 41(5):051907. PubMed ID: 24784386
[TBL] [Abstract][Full Text] [Related]
18. CNN as model observer in a liver lesion detection task for x-ray computed tomography: A phantom study.
Kopp FK; Catalano M; Pfeiffer D; Fingerle AA; Rummeny EJ; Noël PB
Med Phys; 2018 Oct; 45(10):4439-4447. PubMed ID: 30137658
[TBL] [Abstract][Full Text] [Related]
19. Task-specific efficient channel selection and bias management for Gabor function channelized Hotelling observer model for the assessment of x-ray angiography system performance.
Gomez-Cardona D; Favazza CP; Leng S; Schueler BA; Fetterly KA
Med Phys; 2021 Jul; 48(7):3638-3653. PubMed ID: 33656177
[TBL] [Abstract][Full Text] [Related]
20. Amorphous selenium flat panel detectors for digital mammography: validation of a NPWE model observer with CDMAM observer performance experiments.
Segui JA; Zhao W
Med Phys; 2006 Oct; 33(10):3711-22. PubMed ID: 17089837
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]