These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 3085253)

  • 21. [Consideration of inhomogeneities in irradiation planning. 3. Influence of inhomogeneities on the shape of the depth dose curve in water with electronic radiation of different energies (author's transl)].
    Zwicker H; Felix R
    Strahlentherapie; 1977 Feb; 153(2):86-94. PubMed ID: 402714
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The effect of density on the 10MV photon beam penumbra.
    Hoban PW; Keal PJ; Round WH
    Australas Phys Eng Sci Med; 1992 Sep; 15(3):113-23. PubMed ID: 1471961
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Clinical dosimetric studies of lung tissue heterogenetiy in irradiation on the Rokus and B5M-25 machines].
    Afanas'ev BP; Kozlov AP; Luk'ianov VP; Rotenberg MZ; Simbirtseva LP
    Vopr Onkol; 1977; 23(8):37-43. PubMed ID: 410160
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Consideration of inhomogeneities in irradiation planning. I. Influence of inhomogeneities on course of depth dose curve in water for cobalt60 gamma rays].
    Zwicker H; Felix R
    Strahlentherapie; 1976 Aug; 152(2):155-63. PubMed ID: 960135
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Conversion of ionization measurements to radiation absorbed dose in non-water density material.
    el-Khatib E; Connors S
    Phys Med Biol; 1992 Nov; 37(11):2083-94. PubMed ID: 1438563
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Exit dose studies in megavoltage photon therapy.
    Lambert GD; Liversage WE; Hirst AM; Doughty D
    Br J Radiol; 1983 May; 56(665):329-34. PubMed ID: 6405835
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Calculation of the dose for fast electrons using a matrix algorithm (author's transl)].
    Leetz HK
    Strahlentherapie; 1979 Mar; 155(3):181-7. PubMed ID: 107619
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Load to the lung and spinal cord in the treatment of exophageal carcinoma using telecentric-excentric pendulous 42 MeV betatron irradiation].
    Koischwitz D; Frommhold H; Winken R
    Strahlentherapie; 1976 Feb; 151(2):183-91. PubMed ID: 816040
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The influence of lung and bone dosimetry on the choice of radiation energy for total body irradiation.
    el-Khatib E; Connors S; Logus W
    Int J Radiat Oncol Biol Phys; 1992; 23(5):1051-7. PubMed ID: 1639640
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Consideration of inhomogeneities in irradiation planning. 2. Influence of inhomogeneities on the shape of the depth dose curve in water with 42 MeV X-rays (author's transl)].
    Zwicker H; Felix R
    Strahlentherapie; 1977 Jan; 153(1):46-50. PubMed ID: 402040
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Lung dose corrections for 6- and 15-MV x rays.
    Mackie TR; el-Khatib E; Battista J; Scrimger J; Van Dyk J; Cunningham JR
    Med Phys; 1985; 12(3):327-32. PubMed ID: 3925308
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Lung compensator design using an electronic portal imaging device.
    Parsaei H; Hussein S; el-Khatib E
    Med Dosim; 1999; 24(1):67-71. PubMed ID: 10100170
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Improvement of depth dose distributions by addition of small doses from laterally incident beams.
    Woudstra E
    Radiother Oncol; 1988 Sep; 13(1):31-9. PubMed ID: 3141979
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of density correction algorithms for photon-beam dose calculations.
    Tatcher M; Palti S
    Radiology; 1981 Oct; 141(1):201-5. PubMed ID: 7291526
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The influence of ionization chamber and phantom design on the measurement of lung dose in photon beams.
    Rice RK; Hansen JL; Chin LM; Mijnheer BJ; Bjärngard BE
    Med Phys; 1988; 15(6):884-90. PubMed ID: 3237146
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Total skin electron therapy technique for the canine patient.
    Rechner KN; Weeks KJ; Pruitt AF
    Vet Radiol Ultrasound; 2011; 52(3):345-52. PubMed ID: 21342305
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Dose perturbations at interfaces in photon beams: secondary electron transport.
    Werner BL; Das IJ; Salk WN
    Med Phys; 1990; 17(2):212-26. PubMed ID: 2110283
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Response of normal lung to irradiation. Tolerance doses/tolerance volumes in pulmonary radiation syndromes.
    McDonald S; Rubin P; Maasilta P
    Front Radiat Ther Oncol; 1989; 23():255-76; discussion 299-301. PubMed ID: 2697658
    [No Abstract]   [Full Text] [Related]  

  • 39. Calculation of photon dose distributions in an inhomogeneous medium using convolutions.
    Boyer AL; Mok EC
    Med Phys; 1986; 13(4):503-9. PubMed ID: 3090410
    [TBL] [Abstract][Full Text] [Related]  

  • 40. New individual tissue compensators for high-energetic photons. Part I. Principle and procedure.
    Quast U; Krause K
    Strahlentherapie; 1978 May; 154(5):333-41. PubMed ID: 653763
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.