BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 30854447)

  • 1. The Impact of Arterial Input Function Determination Variations on Prostate Dynamic Contrast-Enhanced Magnetic Resonance Imaging Pharmacokinetic Modeling: A Multicenter Data Analysis Challenge, Part II.
    Huang W; Chen Y; Fedorov A; Li X; Jajamovich GH; Malyarenko DI; Aryal MP; LaViolette PS; Oborski MJ; O'Sullivan F; Abramson RG; Jafari-Khouzani K; Afzal A; Tudorica A; Moloney B; Gupta SN; Besa C; Kalpathy-Cramer J; Mountz JM; Laymon CM; Muzi M; Kinahan PE; Schmainda K; Cao Y; Chenevert TL; Taouli B; Yankeelov TE; Fennessy F; Li X
    Tomography; 2019 Mar; 5(1):99-109. PubMed ID: 30854447
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Impact of Arterial Input Function Determination Variations on Prostate Dynamic Contrast-Enhanced Magnetic Resonance Imaging Pharmacokinetic Modeling: A Multicenter Data Analysis Challenge.
    Huang W; Chen Y; Fedorov A; Li X; Jajamovich GH; Malyarenko DI; Aryal MP; LaViolette PS; Oborski MJ; O'Sullivan F; Abramson RG; Jafari-Khouzani K; Afzal A; Tudorica A; Moloney B; Gupta SN; Besa C; Kalpathy-Cramer J; Mountz JM; Laymon CM; Muzi M; Schmainda K; Cao Y; Chenevert TL; Taouli B; Yankeelov TE; Fennessy F; Li X
    Tomography; 2016 Mar; 2(1):56-66. PubMed ID: 27200418
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of two methods for estimating DCE-MRI parameters via individual and cohort based AIFs in prostate cancer: a step towards practical implementation.
    Fedorov A; Fluckiger J; Ayers GD; Li X; Gupta SN; Tempany C; Mulkern R; Yankeelov TE; Fennessy FM
    Magn Reson Imaging; 2014 May; 32(4):321-9. PubMed ID: 24560287
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Repeatability of arterial input functions and kinetic parameters in muscle obtained by dynamic contrast enhanced MR imaging of the head and neck.
    Koopman T; Martens RM; Lavini C; Yaqub M; Castelijns JA; Boellaard R; Marcus JT
    Magn Reson Imaging; 2020 May; 68():1-8. PubMed ID: 31978517
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Relative sensitivities of DCE-MRI pharmacokinetic parameters to arterial input function (AIF) scaling.
    Li X; Cai Y; Moloney B; Chen Y; Huang W; Woods M; Coakley FV; Rooney WD; Garzotto MG; Springer CS
    J Magn Reson; 2016 Aug; 269():104-112. PubMed ID: 27288764
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of repeatability and treatment response in early phase clinical trials using DCE-MRI: comparison of parametric analysis using MR- and CT-derived arterial input functions.
    Rata M; Collins DJ; Darcy J; Messiou C; Tunariu N; Desouza N; Young H; Leach MO; Orton MR
    Eur Radiol; 2016 Jul; 26(7):1991-8. PubMed ID: 26385804
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitative pharmacokinetic analysis of prostate cancer DCE-MRI at 3T: comparison of two arterial input functions on cancer detection with digitized whole mount histopathological validation.
    Fennessy FM; Fedorov A; Penzkofer T; Kim KW; Hirsch MS; Vangel MG; Masry P; Flood TA; Chang MC; Tempany CM; Mulkern RV; Gupta SN
    Magn Reson Imaging; 2015 Sep; 33(7):886-94. PubMed ID: 25683515
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of arterial input function selection on the accuracy of dynamic contrast-enhanced MRI quantitative analysis for the diagnosis of clinically significant prostate cancer.
    Azahaf M; Haberlay M; Betrouni N; Ernst O; Behal H; Duhamel A; Ouzzane A; Puech P
    J Magn Reson Imaging; 2016 Mar; 43(3):737-49. PubMed ID: 26303794
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Patient-specific pharmacokinetic parameter estimation on dynamic contrast-enhanced MRI of prostate: Preliminary evaluation of a novel AIF-free estimation method.
    Ginsburg SB; Taimen P; Merisaari H; Vainio P; Boström PJ; Aronen HJ; Jambor I; Madabhushi A
    J Magn Reson Imaging; 2016 Dec; 44(6):1405-1414. PubMed ID: 27285161
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improved repeatability of dynamic contrast-enhanced MRI using the complex MRI signal to derive arterial input functions: a test-retest study in prostate cancer patients.
    Klawer EME; van Houdt PJ; Simonis FFJ; van den Berg CAT; Pos FJ; Heijmink SWTPJ; Isebaert S; Haustermans K; van der Heide UA
    Magn Reson Med; 2019 May; 81(5):3358-3369. PubMed ID: 30656738
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dynamic contrast-enhanced MRI parametric mapping using high spatiotemporal resolution Golden-angle RAdial Sparse Parallel MRI and iterative joint estimation of the arterial input function and pharmacokinetic parameters.
    Mazaheri Y; Kim N; Lakhman Y; Jafari R; Vargas A; Otazo R
    NMR Biomed; 2022 Jul; 35(7):e4718. PubMed ID: 35226774
    [TBL] [Abstract][Full Text] [Related]  

  • 12. DCE-MRI of the prostate using shutter-speed vs. Tofts model for tumor characterization and assessment of aggressiveness.
    Hectors SJ; Besa C; Wagner M; Jajamovich GH; Haines GK; Lewis S; Tewari A; Rastinehad A; Huang W; Taouli B
    J Magn Reson Imaging; 2017 Sep; 46(3):837-849. PubMed ID: 28092414
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of contrast agent injection duration on dynamic contrast-enhanced MRI quantification in prostate cancer.
    Klawer EME; van Houdt PJ; Pos FJ; Heijmink SWTPJ; van Osch MJP; van der Heide UA
    NMR Biomed; 2018 Sep; 31(9):e3946. PubMed ID: 29974981
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pharmacokinetic analysis of prostate cancer using independent component analysis.
    Mehrabian H; Da Rosa M; Haider MA; Martel AL
    Magn Reson Imaging; 2015 Dec; 33(10):1236-1245. PubMed ID: 26297961
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Operator dependency of arterial input function in dynamic contrast-enhanced MRI.
    Kleppestø M; Bjørnerud A; Groote IR; Kim M; Vardal J; Larsson C
    MAGMA; 2022 Feb; 35(1):105-112. PubMed ID: 34213687
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of Arterial Input Function and Pharmacokinetic Models on DCE-MRI Biomarkers for Detection of Vascular Effect Induced by Stroma-Directed Drug in an Orthotopic Mouse Model of Pancreatic Cancer.
    Cao J; Pickup S; Rosen M; Zhou R
    Mol Imaging Biol; 2023 Aug; 25(4):638-647. PubMed ID: 37166575
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of arterial input function (AIF) on quantitative prostate dynamic contrast-enhanced (DCE) MRI and zonal prostate anatomy.
    Ziayee F; Müller-Lutz A; Gross J; Quentin M; Ullrich T; Heusch P; Arsov C; Rabenalt R; Albers P; Antoch G; Wittsack HJ; Schimmöller L
    Magn Reson Imaging; 2018 Nov; 53():28-33. PubMed ID: 29902565
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Estimating the arterial input function from dynamic contrast-enhanced MRI data with compensation for flow enhancement (II): Applications in spine diagnostics and assessment of crohn's disease.
    van Schie JJN; Lavini C; van Vliet LJ; Kramer G; Pieters-van den Bos I; Marcus JT; Stoker J; Vos FM
    J Magn Reson Imaging; 2018 May; 47(5):1197-1204. PubMed ID: 29193469
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison between population average and experimentally measured arterial input function in predicting biopsy results in prostate cancer.
    Meng R; Chang SD; Jones EC; Goldenberg SL; Kozlowski P
    Acad Radiol; 2010 Apr; 17(4):520-5. PubMed ID: 20074982
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel AIF tracking method and comparison of DCE-MRI parameters using individual and population-based AIFs in human breast cancer.
    Li X; Welch EB; Arlinghaus LR; Chakravarthy AB; Xu L; Farley J; Loveless ME; Mayer IA; Kelley MC; Meszoely IM; Means-Powell JA; Abramson VG; Grau AM; Gore JC; Yankeelov TE
    Phys Med Biol; 2011 Sep; 56(17):5753-69. PubMed ID: 21841212
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.