These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 30855262)

  • 1. Post-reconstruction 3D single-distance phase retrieval for multi-stage phase-contrast tomography with photon-counting detectors.
    Brun F; Brombal L; Di Trapani V; Delogu P; Donato S; Dreossi D; Rigon L; Longo R
    J Synchrotron Radiat; 2019 Mar; 26(Pt 2):510-516. PubMed ID: 30855262
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fast three-dimensional phase retrieval in propagation-based X-ray tomography.
    Thompson DA; Nesterets YI; Pavlov KM; Gureyev TE
    J Synchrotron Radiat; 2019 May; 26(Pt 3):825-838. PubMed ID: 31074448
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Large-area single-photon-counting CdTe detector for synchrotron radiation computed tomography: a dedicated pre-processing procedure.
    Brombal L; Donato S; Brun F; Delogu P; Fanti V; Oliva P; Rigon L; Di Trapani V; Longo R; Golosio B
    J Synchrotron Radiat; 2018 Jul; 25(Pt 4):1068-1077. PubMed ID: 29979168
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Imaging performance of phase-contrast breast computed tomography with synchrotron radiation and a CdTe photon-counting detector.
    Sarno A; Mettivier G; Golosio B; Oliva P; Spandre G; Di Lillo F; Fedon C; Longo R; Russo P
    Phys Med; 2016 May; 32(5):681-90. PubMed ID: 27160829
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monochromatic breast computed tomography with synchrotron radiation: phase-contrast and phase-retrieved image comparison and full-volume reconstruction.
    Brombal L; Golosio B; Arfelli F; Bonazza D; Contillo A; Delogu P; Donato S; Mettivier G; Oliva P; Rigon L; Taibi A; Tromba G; Zanconati F; Longo R
    J Med Imaging (Bellingham); 2019 Jul; 6(3):031402. PubMed ID: 30525064
    [TBL] [Abstract][Full Text] [Related]  

  • 6. 2D and 3D X-ray phase retrieval of multi-material objects using a single defocus distance.
    Beltran MA; Paganin DM; Uesugi K; Kitchen MJ
    Opt Express; 2010 Mar; 18(7):6423-36. PubMed ID: 20389666
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dose fractionation in synchrotron radiation x-ray phase micro-tomography.
    Frachon T; Weber L; Hesse B; Rit S; Dong P; Olivier C; Peyrin F; Langer M
    Phys Med Biol; 2015 Oct; 60(19):7543-66. PubMed ID: 26371834
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Penalized maximum likelihood reconstruction for x-ray differential phase-contrast tomography.
    Brendel B; von Teuffenbach M; Noël PB; Pfeiffer F; Koehler T
    Med Phys; 2016 Jan; 43(1):188. PubMed ID: 26745911
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Poster - Thur Eve - 14: The effect of fluence and detector size on image quality in multi-projection compton scatter tomography.
    Chighvinadze T; Pistorius S
    Med Phys; 2012 Jul; 39(7Part2):4626-4627. PubMed ID: 28516521
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging.
    Shikhaliev PM
    Phys Med Biol; 2006 Sep; 51(17):4267-87. PubMed ID: 16912381
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Photon counting computed tomography: concept and initial results.
    Shikhaliev PM; Xu T; Molloi S
    Med Phys; 2005 Feb; 32(2):427-36. PubMed ID: 15789589
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Advancements towards the implementation of clinical phase-contrast breast computed tomography at Elettra.
    Longo R; Arfelli F; Bonazza D; Bottigli U; Brombal L; Contillo A; Cova MA; Delogu P; Di Lillo F; Di Trapani V; Donato S; Dreossi D; Fanti V; Fedon C; Golosio B; Mettivier G; Oliva P; Pacilè S; Sarno A; Rigon L; Russo P; Taibi A; Tonutti M; Zanconati F; Tromba G
    J Synchrotron Radiat; 2019 Jul; 26(Pt 4):1343-1353. PubMed ID: 31274463
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Three novel accurate pixel-driven projection methods for 2D CT and 3D EPR imaging.
    Qiao Z; Redler G; Gui Z; Qian Y; Epel B; Halpern H
    J Xray Sci Technol; 2018; 26(1):83-102. PubMed ID: 29036875
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: a simulation study.
    Shikhaliev PM
    Phys Med Biol; 2005 Dec; 50(24):5813-27. PubMed ID: 16333157
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Panoramic cone beam computed tomography.
    Chang J; Zhou L; Wang S; Clifford Chao KS
    Med Phys; 2012 May; 39(5):2930-46. PubMed ID: 22559664
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Computed tomography with energy-resolved detection: a feasibility study.
    Shikhaliev PM
    Phys Med Biol; 2008 Mar; 53(5):1475-95. PubMed ID: 18296774
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Towards breast tomography with synchrotron radiation at Elettra: first images.
    Longo R; Arfelli F; Bellazzini R; Bottigli U; Brez A; Brun F; Brunetti A; Delogu P; Di Lillo F; Dreossi D; Fanti V; Fedon C; Golosio B; Lanconelli N; Mettivier G; Minuti M; Oliva P; Pinchera M; Rigon L; Russo P; Sarno A; Spandre G; Tromba G; Zanconati F
    Phys Med Biol; 2016 Feb; 61(4):1634-49. PubMed ID: 26836274
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of ray profile modeling on resolution recovery in clinical CT.
    Hofmann C; Knaup M; Kachelrieß M
    Med Phys; 2014 Feb; 41(2):021907. PubMed ID: 24506628
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cone-beam breast computed tomography with a displaced flat panel detector array.
    Mettivier G; Russo P; Lanconelli N; Meo SL
    Med Phys; 2012 May; 39(5):2805-19. PubMed ID: 22559652
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Gauging low-dose X-ray phase-contrast imaging at a single and large propagation distance.
    Hofmann R; Schober A; Hahn S; Moosmann J; Kashef J; Hertel M; Weinhardt V; Hänschke D; Helfen L; Sánchez Salazar IA; Guigay JP; Xiao X; Baumbach T
    Opt Express; 2016 Feb; 24(4):4331-48. PubMed ID: 26907079
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.