These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

205 related articles for article (PubMed ID: 30856315)

  • 1. Evaluation of a Volumetric Dried Blood Spot Card Using a Gravimetric Method and a Bioanalytical Method with Capillary Blood from 44 Volunteers.
    Lenk G; Ullah S; Stemme G; Beck O; Roxhed N
    Anal Chem; 2019 May; 91(9):5558-5565. PubMed ID: 30856315
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the Capitainer-B Microfluidic Device as a New Hematocrit-Independent Alternative for Dried Blood Spot Collection.
    Velghe S; Stove CP
    Anal Chem; 2018 Nov; 90(21):12893-12899. PubMed ID: 30256092
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study.
    De Kesel PM; Lambert WE; Stove CP
    Anal Chim Acta; 2015 Jun; 881():65-73. PubMed ID: 26041521
    [TBL] [Abstract][Full Text] [Related]  

  • 4. New microfluidic-based sampling procedure for overcoming the hematocrit problem associated with dried blood spot analysis.
    Leuthold LA; Heudi O; Déglon J; Raccuglia M; Augsburger M; Picard F; Kretz O; Thomas A
    Anal Chem; 2015 Feb; 87(4):2068-71. PubMed ID: 25607538
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the Performance and Hematocrit Independence of the HemaPEN as a Volumetric Dried Blood Spot Collection Device.
    Deprez S; Paniagua-González L; Velghe S; Stove CP
    Anal Chem; 2019 Nov; 91(22):14467-14475. PubMed ID: 31638372
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Investigation of the effect of blood hematocrit and lipid content on the blood volume deposited by a disposable dried blood spot collection device.
    Spooner N; Olatunji A; Webbley K
    J Pharm Biomed Anal; 2018 Feb; 149():419-424. PubMed ID: 29154197
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fluispotter, a novel automated and wearable device for accurate volume serial dried blood spot sampling.
    Adhikari KB; Rohde M; Velschow S; Feldt-Rasmussen U; Johannesen J; Johnsen AH
    Bioanalysis; 2020 May; 12(10):665-681. PubMed ID: 32489105
    [No Abstract]   [Full Text] [Related]  

  • 8. Hematocrit-Independent Quantitation of Stimulants in Dried Blood Spots: Pipet versus Microfluidic-Based Volumetric Sampling Coupled with Automated Flow-Through Desorption and Online Solid Phase Extraction-LC-MS/MS Bioanalysis.
    Verplaetse R; Henion J
    Anal Chem; 2016 Jul; 88(13):6789-96. PubMed ID: 27270226
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Precise, accurate and user-independent blood collection system for dried blood spot sample preparation.
    Neto R; Gooley A; Breadmore MC; Hilder EF; Lapierre F
    Anal Bioanal Chem; 2018 May; 410(14):3315-3323. PubMed ID: 29623384
    [TBL] [Abstract][Full Text] [Related]  

  • 10. LC-MS/MS bioanalysis of loratadine (Claritin) in dried blood spot (DBS) samples collected by subjects in a clinical research study.
    Li W; Doherty J; Moench P; Flarakos J; Tse FL
    J Chromatogr B Analyt Technol Biomed Life Sci; 2015 Mar; 983-984():117-24. PubMed ID: 25645810
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A disposable sampling device to collect volume-measured DBS directly from a fingerprick onto DBS paper.
    Lenk G; Sandkvist S; Pohanka A; Stemme G; Beck O; Roxhed N
    Bioanalysis; 2015; 7(16):2085-94. PubMed ID: 26327187
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Volumetric absorptive microsampling: a dried sample collection technique for quantitative bioanalysis.
    Denniff P; Spooner N
    Anal Chem; 2014 Aug; 86(16):8489-95. PubMed ID: 25058158
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Analysis of ochratoxin A in dried blood spots - Correlation between venous and finger-prick blood, the influence of hematocrit and spotted volume.
    Osteresch B; Cramer B; Humpf HU
    J Chromatogr B Analyt Technol Biomed Life Sci; 2016 May; 1020():158-64. PubMed ID: 27046696
    [TBL] [Abstract][Full Text] [Related]  

  • 14. "Center punch" and "whole spot" bioanalysis of apixaban in human dried blood spot samples by UHPLC-MS/MS.
    Zheng N; Yuan L; Ji QC; Mangus H; Song Y; Frost C; Zeng J; Aubry AF; Arnold ME
    J Chromatogr B Analyt Technol Biomed Life Sci; 2015 Apr; 988():66-74. PubMed ID: 25746754
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Manual punch versus automated flow-through sample desorption for dried blood spot LC-MS/MS analysis of voriconazole.
    Martial LC; van den Hombergh E; Tump C; Halmingh O; Burger DM; van Maarseveen EM; Brüggemann RJ; Aarnoutse RE
    J Chromatogr B Analyt Technol Biomed Life Sci; 2018 Jul; 1089():16-23. PubMed ID: 29747155
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of moxifloxacin in dried blood spots using LC-MS/MS and the impact of the hematocrit and blood volume.
    Vu DH; Koster RA; Alffenaar JW; Brouwers JR; Uges DR
    J Chromatogr B Analyt Technol Biomed Life Sci; 2011 May; 879(15-16):1063-70. PubMed ID: 21459055
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fully automated correction for the hematocrit bias of non-volumetric dried blood spot phosphatidylethanol analysis.
    Luginbühl M; Stöth F; Weinmann W; Gaugler S
    Alcohol; 2021 Aug; 94():17-23. PubMed ID: 33865941
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quantitative determination of atenolol in dried blood spot samples by LC-HRMS: a potential method for assessing medication adherence.
    Lawson G; Cocks E; Tanna S
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 May; 897():72-9. PubMed ID: 22552005
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Near-infrared-based hematocrit prediction of dried blood spots: An in-depth evaluation.
    Delahaye L; Heughebaert L; Lühr C; Lambrecht S; Stove CP
    Clin Chim Acta; 2021 Dec; 523():239-246. PubMed ID: 34624275
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development and validation of an LC-MS/MS method for the analysis of ivermectin in plasma, whole blood, and dried blood spots using a fully automatic extraction system.
    Duthaler U; Suenderhauf C; Gaugler S; Vetter B; Krähenbühl S; Hammann F
    J Pharm Biomed Anal; 2019 Aug; 172():18-25. PubMed ID: 31015095
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.