222 related articles for article (PubMed ID: 30871031)
1. Improvement of High Affinity and Selectivity on Biosensors Using Genetically Engineered Phage by Binding Isotherm Screening.
Lee JM; Choi EJ; Park J; Devaraj V; Kim C; Han J; Kim WG; Kim K; Kang YC; Kim KH; Oh JW
Viruses; 2019 Mar; 11(3):. PubMed ID: 30871031
[TBL] [Abstract][Full Text] [Related]
2. M13 Bacteriophage/Silver Nanowire Surface-Enhanced Raman Scattering Sensor for Sensitive and Selective Pesticide Detection.
Koh EH; Mun C; Kim C; Park SG; Choi EJ; Kim SH; Dang J; Choo J; Oh JW; Kim DH; Jung HS
ACS Appl Mater Interfaces; 2018 Mar; 10(12):10388-10397. PubMed ID: 29505228
[TBL] [Abstract][Full Text] [Related]
3. Biomimetic self-templating optical structures fabricated by genetically engineered M13 bacteriophage.
Kim WG; Song H; Kim C; Moon JS; Kim K; Lee SW; Oh JW
Biosens Bioelectron; 2016 Nov; 85():853-859. PubMed ID: 27295572
[TBL] [Abstract][Full Text] [Related]
4. Experimental and numerical evaluation of a genetically engineered M13 bacteriophage with high sensitivity and selectivity for 2,4,6-trinitrotoluene.
Kim WG; Zueger C; Kim C; Wong W; Devaraj V; Yoo HW; Hwang S; Oh JW; Lee SW
Org Biomol Chem; 2019 Jun; 17(23):5666-5670. PubMed ID: 30973549
[TBL] [Abstract][Full Text] [Related]
5. Biomimetic virus-based colourimetric sensors.
Oh JW; Chung WJ; Heo K; Jin HE; Lee BY; Wang E; Zueger C; Wong W; Meyer J; Kim C; Lee SY; Kim WG; Zemla M; Auer M; Hexemer A; Lee SW
Nat Commun; 2014; 5():3043. PubMed ID: 24448217
[TBL] [Abstract][Full Text] [Related]
6. M13 phage-based nanoprobe for SERS detection and inactivation of Staphylococcus aureus.
Wang XY; Yang JY; Wang YT; Zhang HC; Chen ML; Yang T; Wang JH
Talanta; 2021 Jan; 221():121668. PubMed ID: 33076174
[TBL] [Abstract][Full Text] [Related]
7. Investigation of colorimetric biosensor array based on programable surface chemistry of M13 bacteriophage towards artificial nose for volatile organic compound detection: From basic properties of the biosensor to practical application.
Lee JM; Lee Y; Devaraj V; Nguyen TM; Kim YJ; Kim YH; Kim C; Choi EJ; Han DW; Oh JW
Biosens Bioelectron; 2021 Sep; 188():113339. PubMed ID: 34030096
[TBL] [Abstract][Full Text] [Related]
8. M13 phage: a versatile building block for a highly specific analysis platform.
Wang R; Li HD; Cao Y; Wang ZY; Yang T; Wang JH
Anal Bioanal Chem; 2023 Jul; 415(18):3927-3944. PubMed ID: 36867197
[TBL] [Abstract][Full Text] [Related]
9. Non-lytic M13 phage-based highly sensitive impedimetric cytosensor for detection of coliforms.
Sedki M; Chen X; Chen C; Ge X; Mulchandani A
Biosens Bioelectron; 2020 Jan; 148():111794. PubMed ID: 31678821
[TBL] [Abstract][Full Text] [Related]
10. Hotspots engineering by grafting Au@Ag core-shell nanoparticles on the Au film over slightly etched nanoparticles substrate for on-site paraquat sensing.
Wang C; Wu X; Dong P; Chen J; Xiao R
Biosens Bioelectron; 2016 Dec; 86():944-950. PubMed ID: 27498319
[TBL] [Abstract][Full Text] [Related]
11. Modified Filamentous Bacteriophage as a Scaffold for Carbon Nanofiber.
Szot-Karpińska K; Golec P; Leśniewski A; Pałys B; Marken F; Niedziółka-Jönsson J; Węgrzyn G; Łoś M
Bioconjug Chem; 2016 Dec; 27(12):2900-2910. PubMed ID: 27748604
[TBL] [Abstract][Full Text] [Related]
12. Fabrication of a silica nanocable using hydroxyl-group core-engineered filamentous virus.
Kim YJ; Hwang KH; Park SJ; Jeon DY; Nam CH; Kim GT
J Nanosci Nanotechnol; 2013 Sep; 13(9):6203-7. PubMed ID: 24205629
[TBL] [Abstract][Full Text] [Related]
13. Engineering of M13 Bacteriophage for Development of Tissue Engineering Materials.
Jin HE; Lee SW
Methods Mol Biol; 2018; 1776():487-502. PubMed ID: 29869262
[TBL] [Abstract][Full Text] [Related]
14. Construction and screening of M13 phage libraries displaying long random peptides.
McConnell SJ; Uveges AJ; Fowlkes DM; Spinella DG
Mol Divers; 1996 May; 1(3):165-76. PubMed ID: 9237207
[TBL] [Abstract][Full Text] [Related]
15. M13 bacteriophage as biometric component for orderly assembly of dynamic light scattering immunosensor.
Zhan S; Fang H; Chen Q; Xiong S; Guo Y; Huang T; Li X; Leng Y; Huang X; Xiong Y
Biosens Bioelectron; 2022 Dec; 217():114693. PubMed ID: 36108584
[TBL] [Abstract][Full Text] [Related]
16. Phage-based capacitive biosensor for Salmonella detection.
Niyomdecha S; Limbut W; Numnuam A; Kanatharana P; Charlermroj R; Karoonuthaisiri N; Thavarungkul P
Talanta; 2018 Oct; 188():658-664. PubMed ID: 30029427
[TBL] [Abstract][Full Text] [Related]
17. General M13 phage display: M13 phage display in identification and characterization of protein-protein interactions.
Hertveldt K; Beliën T; Volckaert G
Methods Mol Biol; 2009; 502():321-39. PubMed ID: 19082565
[TBL] [Abstract][Full Text] [Related]
18. Design and evolution of artificial M13 coat proteins.
Weiss GA; Sidhu SS
J Mol Biol; 2000 Jun; 300(1):213-9. PubMed ID: 10864510
[TBL] [Abstract][Full Text] [Related]
19. Selection of staphylococcal enterotoxin B (SEB)-binding peptide using phage display technology.
Soykut EA; Dudak FC; Boyaci IH
Biochem Biophys Res Commun; 2008 May; 370(1):104-8. PubMed ID: 18359289
[TBL] [Abstract][Full Text] [Related]
20. Evolutionary screening and adsorption behavior of engineered M13 bacteriophage and derived dodecapeptide for selective decoration of gold interfaces.
Causa F; Della Moglie R; Iaccino E; Mimmi S; Marasco D; Scognamiglio PL; Battista E; Palmieri C; Cosenza C; Sanguigno L; Quinto I; Scala G; Netti PA
J Colloid Interface Sci; 2013 Jan; 389(1):220-9. PubMed ID: 23031494
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]