These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

283 related articles for article (PubMed ID: 30873888)

  • 1. A modified magnetic resonance wireless power transfer system for capsule endoscopy.
    Miarnaeimi M; Ghalibafan J; Hashemi SM
    Electromagn Biol Med; 2019; 38(2):158-167. PubMed ID: 30873888
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Portable wireless power transmission system for video capsule endoscopy.
    Zhiwei J; Guozheng Y; Bingquan Z
    J Med Eng Technol; 2014 Oct; 38(7):351-8. PubMed ID: 25082182
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Application of wireless power transmission systems in wireless capsule endoscopy: an overview.
    Basar MR; Ahmad MY; Cho J; Ibrahim F
    Sensors (Basel); 2014 Jun; 14(6):10929-51. PubMed ID: 24949645
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [A wireless power transmission system for capsule endoscope].
    Xin W; Yan G; Wang W
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2010 Jun; 27(3):490-4. PubMed ID: 20649004
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Towards a Miniaturized 3D Receiver WPT System for Capsule Endoscopy.
    Khan SR; Desmulliez MPY
    Micromachines (Basel); 2019 Aug; 10(8):. PubMed ID: 31426541
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A two-hop wireless power transfer system with an efficiency-enhanced power receiver for motion-free capsule endoscopy inspection.
    Sun T; Xie X; Li G; Gu Y; Deng Y; Wang Z
    IEEE Trans Biomed Eng; 2012 Nov; 59(11):3247-54. PubMed ID: 22759436
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Design and analysis of a wireless power transfer system for capsule robot using an optimised planar square spiral transmitting coil pair.
    Zhuang H; Wang W; Zhao K; Fei Q; Yan G
    Int J Med Robot; 2022 Aug; 18(4):e2399. PubMed ID: 35397196
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Micro-intestinal robot with wireless power transmission: design, analysis and experiment.
    Shi Y; Yan G; Chen W; Zhu B
    Comput Biol Med; 2015 Nov; 66():343-51. PubMed ID: 26278992
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Tracking and Dynamic Tuning of a Wireless Powered Endoscopic Capsule.
    Murliky L; Oliveira G; de Sousa FR; Brusamarello VJ
    Sensors (Basel); 2022 Sep; 22(18):. PubMed ID: 36146266
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Modelling on mutual inductance of wireless power transfer for capsule endoscopy.
    Kuang S; Yan G
    Biomed Microdevices; 2020 Aug; 22(3):54. PubMed ID: 32789771
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A portable wireless power transmission system for video capsule endoscopes.
    Shi Y; Yan G; Zhu B; Liu G
    Biomed Mater Eng; 2015; 26 Suppl 1():S1721-30. PubMed ID: 26405939
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis and Optimization of Four-Coil Planar Magnetically Coupled Printed Spiral Resonators.
    Khan SR; Choi G
    Sensors (Basel); 2016 Aug; 16(8):. PubMed ID: 27527169
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Low-power wireless electronic capsule for long-term gastrointestinal monitoring.
    Zhao K; Yan G; Lu L; Xu F
    J Med Syst; 2015 Feb; 39(2):9. PubMed ID: 25631843
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Wireless power transmission in endoscopy capsules.
    Kühne M; Andrä W; Werner C; Bellemann ME
    Biomed Tech (Berl); 2019 Dec; 64(6):677-682. PubMed ID: 31785193
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Wireless Power Transmission with Uniform Power Delivery in the 3D Space of the Human Body using Resonators in Parallel.
    Saha R; Roy Joy B; Mirbozorgi SA
    Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():7268-7271. PubMed ID: 34892776
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An asymmetric resonant coupling wireless power transmission link for Micro-Ball Endoscopy.
    Sun T; Xie X; Li G; Gu Y; Deng Y; Wang Z; Wang Z
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():6531-4. PubMed ID: 21096499
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Wireless Power Transfer Techniques for Implantable Medical Devices: A Review.
    Khan SR; Pavuluri SK; Cummins G; Desmulliez MPY
    Sensors (Basel); 2020 Jun; 20(12):. PubMed ID: 32575663
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Resonant System for In Vitro Studies Emulating Wireless Power Transfer Exposure at 13.56 MHz.
    Koohestani M; Perdriau R; Le Dréan Y; Ettorre M; Zhadobov M
    Bioelectromagnetics; 2020 Jul; 41(5):369-381. PubMed ID: 32452076
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A wireless capsule robot with spiral legs for human intestine.
    Chen W; Yan G; Wang Z; Jiang P; Liu H
    Int J Med Robot; 2014 Jun; 10(2):147-61. PubMed ID: 23843276
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Robust Wireless Power Transmission to mm-Sized Free-Floating Distributed Implants.
    Mirbozorgi SA; Yeon P; Ghovanloo M
    IEEE Trans Biomed Circuits Syst; 2017 Jun; 11(3):692-702. PubMed ID: 28504947
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.