These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
6. Methods of polarimetric calibration and reconstruction for a fieldable channeled dispersive imaging spectropolarimeter. Yang B; Zhang J; Yan C; Ju X Appl Opt; 2017 Oct; 56(30):8477-8491. PubMed ID: 29091628 [TBL] [Abstract][Full Text] [Related]
7. Polarimetric calibration method for the fore-optics of a channeled spectropolarimeter. Liu P; Yang B; Liang H; Ju X; Dai H; Yan C; Zhang T Opt Express; 2023 Dec; 31(25):41046-41059. PubMed ID: 38087513 [TBL] [Abstract][Full Text] [Related]
8. In-Orbit Calibration of Phase Retardance for Channeled Spectropolarimeter. Dong Y; Ju X; Yuan J; Yan C; Zhang T Sensors (Basel); 2023 Feb; 23(5):. PubMed ID: 36904846 [TBL] [Abstract][Full Text] [Related]
10. Linear operator theory of channeled spectropolarimetry. Sabatke DS; Locke AM; Dereniak EL; McMillan RW J Opt Soc Am A Opt Image Sci Vis; 2005 Aug; 22(8):1567-76. PubMed ID: 16134852 [TBL] [Abstract][Full Text] [Related]
11. Linear calibration and reconstruction techniques for channeled spectropolarimetry. Sabatke D; Locke A; Dereniak E; McMillan R Opt Express; 2003 Nov; 11(22):2940-52. PubMed ID: 19471414 [TBL] [Abstract][Full Text] [Related]
12. Reconstruction and calibration methods for a Mueller channeled spectropolarimeter. Zhou G; Li Y; Liu K Opt Express; 2022 Jan; 30(2):2018-2032. PubMed ID: 35209351 [TBL] [Abstract][Full Text] [Related]
15. Athermalized channeled spectropolarimetry using a biaxial potassium titanyl phosphate crystal. Craven-Jones J; Way BM; Kudenov MW; Mercier JA Opt Lett; 2013 May; 38(10):1657-9. PubMed ID: 23938901 [TBL] [Abstract][Full Text] [Related]
16. Realization of quantitative-grade fieldable snapshot imaging spectropolarimeter. Jones S; Iannarilli F; Kebabian P Opt Express; 2004 Dec; 12(26):6559-73. PubMed ID: 19488307 [TBL] [Abstract][Full Text] [Related]
17. Derivation and calibration of spectral response for a channeled spectropolarimeter. Zhao Z; Li Y; Liu K; Zhou G Opt Express; 2023 Jul; 31(16):25763-25780. PubMed ID: 37710454 [TBL] [Abstract][Full Text] [Related]
18. Spectroscopic polarimetry using channeled spectroscopic polarization state generator (CSPSG). Okabe H; Hayakawa M; Naito H; Taniguchi A; Oka K Opt Express; 2007 Mar; 15(6):3093-109. PubMed ID: 19532548 [TBL] [Abstract][Full Text] [Related]
19. Self-correction of alignment errors and retardations for a channeled spectropolarimeter. Xing W; Ju X; Yan C; Yang B; Zhang J Appl Opt; 2018 Sep; 57(27):7857-7864. PubMed ID: 30462051 [TBL] [Abstract][Full Text] [Related]