4. Impact of optimizing pre-analytical phase on the diagnosis of gestational diabetes and related outcomes. Szoke D; Borille S; Cardellicchio M; Spadaccini G; Taricco E; Vignali M; Cetin I; Birindelli S; Panteghini M Clin Chem Lab Med; 2021 Nov; 59(12):1981-1987. PubMed ID: 34449173 [TBL] [Abstract][Full Text] [Related]
5. Liquid citrate acidification introduces significant glucose bias and leads to misclassification of patients with diabetes. Juricic G; Kopcinovic LM; Saracevic A; Bakliza A; Simundic AM Clin Chem Lab Med; 2016 Feb; 54(2):363-71. PubMed ID: 26136303 [TBL] [Abstract][Full Text] [Related]
6. Technical and clinical validation of the Greiner FC-Mix glycaemia tube. van der Hagen EAE; Fokkert MJ; Kleefman AMD; Thelen MHM; van den Berg SAA; Slingerland RJ Clin Chem Lab Med; 2017 Aug; 55(10):1530-1536. PubMed ID: 28284032 [TBL] [Abstract][Full Text] [Related]
7. Effectiveness of citrate buffer-fluoride mixture in Terumo tubes as an inhibitor of in vitro glycolysis. Bonetti G; Carta M; Montagnana M; Lo Cascio C; Bonfigli AR; Mosca A; Testa R; Biochem Med (Zagreb); 2016; 26(1):68-76. PubMed ID: 26981020 [TBL] [Abstract][Full Text] [Related]
8. Stability of glucose in plasma with different anticoagulants. Fobker M Clin Chem Lab Med; 2014 Jul; 52(7):1057-60. PubMed ID: 24633752 [TBL] [Abstract][Full Text] [Related]
9. Glucose meters: What's the laboratory reference glucose? Carta M; Giavarina D; Paternoster A; Bonetti G J Med Biochem; 2020 Jan; 39(1):32-39. PubMed ID: 32549775 [TBL] [Abstract][Full Text] [Related]
10. Five days serum glucose stability at room-temperature in centrifuged fast-clotting serum tubes and the comparability with glucose in heparin-plasma and plasma containing citrate-stabilizer. Bakkebø H; Haaland KL; Hoff KS; Schwettmann L Scand J Clin Lab Invest; 2024 Feb; 84(1):62-67. PubMed ID: 38451167 [TBL] [Abstract][Full Text] [Related]
11. Real-World Gestational Diabetes Screening: Problems with the Oral Glucose Tolerance Test in Rural and Remote Australia. Jamieson EL; Spry EP; Kirke AB; Atkinson DN; Marley JV Int J Environ Res Public Health; 2019 Nov; 16(22):. PubMed ID: 31739513 [TBL] [Abstract][Full Text] [Related]
12. Recommended pre-analytical plasma glucose sampling methodology may distort gestational diabetes mellitus prevalence: implications for diagnostic thresholds. Song D; Lia M; Hurley JC Diabet Med; 2019 Oct; 36(10):1226-1233. PubMed ID: 31295362 [TBL] [Abstract][Full Text] [Related]
13. How pre-analytical conditions impact glucose measurement and (gestational) diabetes diagnosis: A real-world stability study and a call for harmonization. Nevraumont A; Deltombe M; Bayart JL Clin Chim Acta; 2024 Aug; 562():119875. PubMed ID: 39013524 [TBL] [Abstract][Full Text] [Related]
14. Oral glucose tolerance test to diagnose gestational diabetes mellitus: Impact of variations in specimen handling. Jamieson EL; Dimeski G; Flatman R; Hickman PE; Ross Dallas Jones G; V Marley J; David McIntyre H; McNeil AR; Nolan CJ; Potter JM; Sweeting A; Ward P; Williams P; Rita Horvath A Clin Biochem; 2023 May; 115():33-48. PubMed ID: 36244469 [TBL] [Abstract][Full Text] [Related]
15. Heterogeneity of pregnancy outcomes and risk of LGA neonates in Caucasian females according to IADPSG criteria for gestational diabetes mellitus. Disse E; Graeppi-Dulac J; Joncour-Mills G; Dupuis O; Thivolet C Diabetes Metab; 2013 Apr; 39(2):132-8. PubMed ID: 23182459 [TBL] [Abstract][Full Text] [Related]
16. One-hour oral glucose tolerance test plasma glucose at gestational diabetes diagnosis is a common predictor of the need for insulin therapy in pregnancy and postpartum impaired glucose tolerance. Nishikawa T; Ono K; Hashimoto S; Kinoshita H; Watanabe T; Araki H; Otsu K; Sakamoto W; Harada M; Toyonaga T; Kawakami S; Fukuda J; Haga Y; Kukidome D; Takahashi T; Araki E J Diabetes Investig; 2018 Nov; 9(6):1370-1377. PubMed ID: 29624902 [TBL] [Abstract][Full Text] [Related]
17. Fasting plasma glucose is not sufficient to detect ongoing glucose intolerance after pregnancy complicated by gestational diabetes. Kakad R; Anwar A; Dyer P; Webber J; Dale J Exp Clin Endocrinol Diabetes; 2010 Apr; 118(4):234-6. PubMed ID: 20162508 [TBL] [Abstract][Full Text] [Related]
18. What is the most suitable blood collection tube for glucose estimation? Dimeski G; Yow KS; Brown NN Ann Clin Biochem; 2015 Mar; 52(Pt 2):270-5. PubMed ID: 25002707 [TBL] [Abstract][Full Text] [Related]
19. Impaired glucose tolerance of pregnancy is a heterogeneous metabolic disorder as defined by the glycemic response to the oral glucose tolerance test. Retnakaran R; Zinman B; Connelly PW; Sermer M; Hanley AJ Diabetes Care; 2006 Jan; 29(1):57-62. PubMed ID: 16373896 [TBL] [Abstract][Full Text] [Related]
20. Comparison of Citrate Buffer with Sodium Fluoride as Additives in Determining Glycemia. Toro-Crespo M; Maesa-Marquez JM; Sanchez-Margalet V; Gonzalez-Rodriguez C; Fernandez-Riejos P Clin Lab; 2017 Nov; 63(11):1939-1944. PubMed ID: 29226646 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]