These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 30876127)

  • 1. Image gradient L
    Yu H; Wu W; Chen P; Gong C; Jiang J; Wang S; Liu F; Yu H
    Opt Express; 2019 Feb; 27(4):5264-5279. PubMed ID: 30876127
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Low-dose spectral CT reconstruction based on image-gradient L
    Wang S; Wu W; Feng J; Liu F; Yu H
    Phys Med Biol; 2020 Dec; 65(24):245005. PubMed ID: 32693399
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Swinging multi-source industrial CT systems for aperiodic dynamic imaging.
    Wu W; Yu H; Gong C; Liu F
    Opt Express; 2017 Oct; 25(20):24215-24235. PubMed ID: 29041367
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Nonconvex prior image constrained compressed sensing (NCPICCS): theory and simulations on perfusion CT.
    Ramirez-Giraldo JC; Trzasko J; Leng S; Yu L; Manduca A; McCollough CH
    Med Phys; 2011 Apr; 38(4):2157-67. PubMed ID: 21626949
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Prior image constrained compressed sensing: implementation and performance evaluation.
    Lauzier PT; Tang J; Chen GH
    Med Phys; 2012 Jan; 39(1):66-80. PubMed ID: 22225276
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Incorporation of local dependent reliability information into the Prior Image Constrained Compressed Sensing (PICCS) reconstruction algorithm.
    Vaegler S; Stsepankou D; Hesser J; Sauer O
    Z Med Phys; 2015 Dec; 25(4):375-390. PubMed ID: 26422578
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): performance studies.
    Tang J; Hsieh J; Chen GH
    Med Phys; 2010 Aug; 37(8):4377-88. PubMed ID: 20879597
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accurate and robust sparse-view angle CT image reconstruction using deep learning and prior image constrained compressed sensing (DL-PICCS).
    Zhang C; Li Y; Chen GH
    Med Phys; 2021 Oct; 48(10):5765-5781. PubMed ID: 34458996
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT.
    Lauzier PT; Chen GH
    Med Phys; 2012 Oct; 39(10):5930-48. PubMed ID: 23039632
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Locally linear transform based three-dimensional gradient
    Wang Q; Wu W; Deng S; Zhu Y; Yu H
    Med Phys; 2020 Oct; 47(10):4810-4826. PubMed ID: 32740956
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON): A statistical model based iterative image reconstruction method to eliminate limited-view artifacts and to mitigate the temporal-average artifacts in time-resolved CT.
    Chen GH; Li Y
    Med Phys; 2015 Aug; 42(8):4698-707. PubMed ID: 26233197
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets.
    Chen GH; Tang J; Leng S
    Med Phys; 2008 Feb; 35(2):660-3. PubMed ID: 18383687
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.
    Lauzier PT; Chen GH
    Med Phys; 2013 Feb; 40(2):021902. PubMed ID: 23387750
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reduced image noise at low-dose multidetector CT of the abdomen with prior image constrained compressed sensing algorithm.
    Lubner MG; Pickhardt PJ; Tang J; Chen GH
    Radiology; 2011 Jul; 260(1):248-56. PubMed ID: 21436086
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Edge-preserving reconstruction from sparse projections of limited-angle computed tomography using ℓ
    Yu W; Wang C; Huang M
    Rev Sci Instrum; 2017 Apr; 88(4):043703. PubMed ID: 28456252
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tomosynthesis via Total Variation Minimization Reconstruction and Prior Image Constrained Compressed Sensing (PICCS) on a C-arm System.
    Nett B; Tang J; Leng S; Chen GH
    Proc SPIE Int Soc Opt Eng; 2008 Mar; 6913():nihpa92672. PubMed ID: 19756260
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Compressed Imaging Reconstruction Based on Block Compressed Sensing with Conjugate Gradient Smoothed
    Zhang Y; Chen X; Zeng C; Gao K; Li S
    Sensors (Basel); 2023 May; 23(10):. PubMed ID: 37430785
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Non-local total-variation (NLTV) minimization combined with reweighted L1-norm for compressed sensing CT reconstruction.
    Kim H; Chen J; Wang A; Chuang C; Held M; Pouliot J
    Phys Med Biol; 2016 Sep; 61(18):6878-6891. PubMed ID: 27589006
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Spatiotemporal structure-aware dictionary learning-based 4D CBCT reconstruction.
    Zhi S; Kachelrieß M; Mou X
    Med Phys; 2021 Oct; 48(10):6421-6436. PubMed ID: 34514608
    [TBL] [Abstract][Full Text] [Related]  

  • 20. ℓ0 Gradient Minimization Based Image Reconstruction for Limited-Angle Computed Tomography.
    Yu W; Zeng L
    PLoS One; 2015; 10(7):e0130793. PubMed ID: 26158543
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.