BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

394 related articles for article (PubMed ID: 30885047)

  • 1. Is minimally invasive plate osteosynthesis superior to open plating for fixation of two-part fracture of the proximal humerus?
    Kim YG; Park KH; Kim JW; Oh JK; Yoon JP; Kim HJ; Oh CW
    J Orthop Surg (Hong Kong); 2019; 27(2):2309499019836156. PubMed ID: 30885047
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical comparison between open plating and minimally invasive plate osteosynthesis for displaced proximal humeral fractures: A prospective randomized controlled trial.
    Sohn HS; Jeon YS; Lee J; Shin SJ
    Injury; 2017 Jun; 48(6):1175-1182. PubMed ID: 28372791
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison between antegrade intramedullary nailing (IMN), open reduction plate osteosynthesis (ORPO) and minimally invasive plate osteosynthesis (MIPO) in treatment of humerus diaphyseal fractures.
    Kulkarni VS; Kulkarni MS; Kulkarni GS; Goyal V; Kulkarni MG
    Injury; 2017 Aug; 48 Suppl 2():S8-S13. PubMed ID: 28802426
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison between open plating versus minimally invasive plate osteosynthesis for acute displaced clavicular shaft fractures.
    Sohn HS; Kim WJ; Shon MS
    Injury; 2015 Aug; 46(8):1577-84. PubMed ID: 26077663
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Minimally invasive plate osteosynthesis with a locking compression plate is superior to open reduction and internal fixation in the management of the proximal humerus fractures.
    Lin T; Xiao B; Ma X; Fu D; Yang S
    BMC Musculoskelet Disord; 2014 Jun; 15():206. PubMed ID: 24934152
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Effectiveness comparison of two minimally invasive plate osteosynthesis techniques for proximal humeral shaft fractures].
    Wang X; Sun K; Tang L; Liang B; Yin D
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Feb; 37(2):147-152. PubMed ID: 36796807
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dynamic contrast-enhanced ultrasound (CEUS) after open and minimally invasive locked plating of proximal humerus fractures.
    Fischer C; Frank M; Kunz P; Tanner M; Weber MA; Moghaddam A; Schmidmaier G; Hug A
    Injury; 2016 Aug; 47(8):1725-31. PubMed ID: 27242329
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Minimally invasive plate osteosynthesis with PHILOS plate for proximal humerus fractures.
    Gönç U; Atabek M; Teker K; Tanrıöver A
    Acta Orthop Traumatol Turc; 2017 Jan; 51(1):17-22. PubMed ID: 27866913
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures.
    Jeong JJ; Park SE; Lee HH; Ji JH; Park MS; Park YT
    BMC Musculoskelet Disord; 2019 Aug; 20(1):381. PubMed ID: 31421675
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis.
    Kim JW; Oh CW; Byun YS; Kim JJ; Park KC
    J Orthop Trauma; 2015 Apr; 29(4):189-94. PubMed ID: 25210833
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Minimally invasive plate osteosynthesis for proximal humeral fractures: clinical and radiologic outcomes according to fracture type.
    Sohn HS; Shin SJ
    J Shoulder Elbow Surg; 2014 Sep; 23(9):1334-40. PubMed ID: 24618198
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison between minimally invasive plate osteosynthesis and open reduction-internal fixation for proximal humeral fractures: a meta-analysis based on 1050 individuals.
    Li F; Liu X; Wang F; Gu Z; Tao Q; Yao C; Luo X; Nie T
    BMC Musculoskelet Disord; 2019 Nov; 20(1):550. PubMed ID: 31739803
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of post-operative numbness and patient satisfaction using minimally invasive plate osteosynthesis or open plating for acute displaced clavicular shaft fractures.
    You JM; Wu YS; Wang Y
    Int J Surg; 2018 Aug; 56():21-25. PubMed ID: 29890301
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Minimally Invasive Plate Osteosynthesis Using a Screw Compression Method for Treatment of Humeral Shaft Fractures.
    Ko SH; Cha JR; Lee CC; Joo YT; Eom KS
    Clin Orthop Surg; 2017 Dec; 9(4):506-513. PubMed ID: 29201304
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Lessons learned from treating patients with unstable multifragmentary fractures of the proximal humerus by minimal invasive plate osteosynthesis.
    Oh HK; Cho DY; Choo SK; Park JW; Park KC; Lee JI
    Arch Orthop Trauma Surg; 2015 Feb; 135(2):235-242. PubMed ID: 25552395
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical outcomes of minimally invasive open reduction and internal fixation by screw and washer for displaced greater tuberosity fracture of the humerus.
    Yoon TH; Choi CH; Choi YR; Oh JT; Chun YM
    J Shoulder Elbow Surg; 2018 Jun; 27(6):e173-e177. PubMed ID: 29305100
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Comparison of curative effects between minimally invasive locking plate internal fixation and open reduction with internal fixation for the treatment of proximal humerus fractures].
    Shang LP; Zhou F; Ji HQ; Zhang ZS; Liu XG; Tian Y
    Beijing Da Xue Xue Bao Yi Xue Ban; 2013 Oct; 45(5):711-6. PubMed ID: 24136264
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Minimally invasive plate osteosynthesis for proximal humeral fractures.
    Koljonen PA; Fang C; Lau TW; Leung F; Cheung NW
    J Orthop Surg (Hong Kong); 2015 Aug; 23(2):160-3. PubMed ID: 26321541
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Antero-lateral minimally invasive plate osteosynthesis (MIPO) with the radial nerve exploration for extra-articular distal-third diaphyseal fractures of the humerus.
    Zhao W; Qu W; Fu C; Jiang H; Liu S; Cheng C
    Int Orthop; 2017 Sep; 41(9):1757-1762. PubMed ID: 28577034
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel surgical approach and technique and short-term clinical efficacy for the treatment of proximal humerus fractures with the combined use of medial anatomical locking plate fixation and minimally invasive lateral locking plate fixation.
    Wang F; Wang Y; Dong J; He Y; Li L; Liu F; Dong J
    J Orthop Surg Res; 2021 Jan; 16(1):29. PubMed ID: 33422119
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.