These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 30903754)

  • 1. Evaluation of reference change values for a hs-cTnI immunoassay using both plasma samples of healthy subjects and patients and quality control samples.
    Musetti V; Masotti S; Prontera C; Ndreu R; Zucchelli G; Passino C; Emdin M; Clerico A
    Clin Chem Lab Med; 2019 Sep; 57(10):e241-e243. PubMed ID: 30903754
    [No Abstract]   [Full Text] [Related]  

  • 2. Clinical chemistry score versus high-sensitivity cardiac troponin I and T tests alone to identify patients at low or high risk for myocardial infarction or death at presentation to the emergency department.
    Kavsak PA; Neumann JT; Cullen L; Than M; Shortt C; Greenslade JH; Pickering JW; Ojeda F; Ma J; Clayton N; Sherbino J; Hill SA; McQueen M; Westermann D; Sörensen NA; Parsonage WA; Griffith L; Mehta SR; Devereaux PJ; Richards M; Troughton R; Pemberton C; Aldous S; Blankenberg S; Worster A
    CMAJ; 2018 Aug; 190(33):E974-E984. PubMed ID: 30127037
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Head-to-head comparison of plasma cTnI concentration values measured with three high-sensitivity methods in a large Italian population of healthy volunteers and patients admitted to emergency department with acute coronary syndrome: A multi-center study.
    Clerico A; Ripoli A; Zaninotto M; Masotti S; Musetti V; Ciaccio M; Aloe R; Rizzardi S; Dittadi R; Carrozza C; Fasano T; Perrone M; de Santis A; Prontera C; Riggio D; Guiotto C; Migliardi M; Bernardini S; Plebani M
    Clin Chim Acta; 2019 Sep; 496():25-34. PubMed ID: 31201817
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of analytical performance of immunoassay methods for cTnI and cTnT: From theory to practice.
    Clerico A; Zaninotto M; Padoan A; Masotti S; Musetti V; Prontera C; Ndreu R; Zucchelli G; Passino C; Migliardi M; Plebani M
    Adv Clin Chem; 2019; 93():239-262. PubMed ID: 31655731
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of 99th percentile and reference change values of a high-sensitivity cTnI method: A multicenter study.
    Clerico A; Ripoli A; Masotti S; Musetti V; Aloe R; Dipalo M; Rizzardi S; Dittadi R; Carrozza C; Storti S; Belloni L; Perrone M; Fasano T; Canovi S; Correale M; Prontera C; Guiotto C; Cosseddu D; Migliardi M; Bernardini S
    Clin Chim Acta; 2019 Jun; 493():156-161. PubMed ID: 30826369
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical evaluation of Ortho Clinical Diagnostics high-sensitivity cardiac Troponin I assay in patients with symptoms suggestive of acute coronary syndrome.
    Kavsak PA; Mondoux SE; Sherbino J; Ma J; Clayton N; Hill SA; McQueen M; Mehta SR; Griffith LE; Devereaux PJ; Worster A
    Clin Biochem; 2020 Jun; 80():48-51. PubMed ID: 32304695
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Superiority of high sensitivity cardiac troponin T vs. I for long-term prognostic value in patients with chest pain; data from the Akershus cardiac Examination (ACE) 3 study.
    Tveit SH; Myhre PL; Hoff NJS; Le TM; Seljeflot I; Røysland R; Høiseth AD; Røsjø H; Omland T
    Clin Biochem; 2020 Apr; 78():10-17. PubMed ID: 31899280
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rule-out of non-ST elevation myocardial infarction by five point of care cardiac troponin assays according to the 0 h/3 h algorithm of the European Society of Cardiology.
    Suh D; Keller DI; Hof D; von Eckardstein A; Gawinecka J
    Clin Chem Lab Med; 2018 Mar; 56(4):649-657. PubMed ID: 29257750
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analytical characteristics of high-sensitivity cardiac troponin assays.
    Apple FS; Collinson PO;
    Clin Chem; 2012 Jan; 58(1):54-61. PubMed ID: 21965555
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reference values of galectin-3 and cardiac troponins derived from a single cohort of healthy blood donors.
    Mueller T; Egger M; Leitner I; Gabriel C; Haltmayer M; Dieplinger B
    Clin Chim Acta; 2016 May; 456():19-23. PubMed ID: 26920637
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Variation of cardiac troponin I and T measured with sensitive assays in emergency department patients with noncardiac chest pain.
    Scharnhorst V; Krasznai K; van 't Veer M; Michels RH
    Clin Chem; 2012 Aug; 58(8):1208-14. PubMed ID: 22685128
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prognostic value of high-sensitivity troponin I versus troponin T in acute coronary syndromes.
    Correia LC; Sodré FL; Lima JC; Sabino M; Brito M; Garcia G; Maraux M; Sousa AC; Noya-Rabelo M; Esteves JP
    Arq Bras Cardiol; 2012 May; 98(5):406-12. PubMed ID: 22481641
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Analytical evaluation of a high-sensitivity troponin T assay and its clinical assessment in acute coronary syndrome.
    Chenevier-Gobeaux C; Meune C; Blanc MC; Cynober L; Jaffray P; Lefevre G
    Ann Clin Biochem; 2011 Sep; 48(Pt 5):452-8. PubMed ID: 21697353
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Harmonization of Cardiac Troponin I: Significance of Sample Types.
    Ko DH; Hyun J; Kim HS; Park MJ; Shin DH
    Clin Lab; 2019 Apr; 65(4):. PubMed ID: 30969071
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Outlier removal methods for skewed data: impact on age-specific high-sensitive cardiac troponin T 99th percentiles.
    Monneret D; Gellerstedt M; Roche F; Bonnefont-Rousselot D
    Clin Chem Lab Med; 2019 Sep; 57(10):e244-e247. PubMed ID: 30860976
    [No Abstract]   [Full Text] [Related]  

  • 16. Long-term prognostic value of cardiac troponin I and T versus creatine kinase-MB mass after cardiac surgery in low-risk patients with stable symptoms.
    Vikenes K; Andersen KS; Melberg T; Farstad M; Nordrehaug JE
    Am J Cardiol; 2010 Sep; 106(6):780-6. PubMed ID: 20816117
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Weekly and 90-minute biological variations in cardiac troponin T and cardiac troponin I in hemodialysis patients and healthy controls.
    Aakre KM; Røraas T; Petersen PH; Svarstad E; Sellevoll H; Skadberg Ø; Sæle K; Sandberg S
    Clin Chem; 2014 Jun; 60(6):838-47. PubMed ID: 24619542
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of analytical performance of a new high-sensitivity immunoassay for cardiac troponin I.
    Masotti S; Prontera C; Musetti V; Storti S; Ndreu R; Zucchelli GC; Passino C; Clerico A
    Clin Chem Lab Med; 2018 Feb; 56(3):492-501. PubMed ID: 28941350
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improved efficiency and cost reduction in the emergency department by replacing contemporary sensitive with high-sensitivity cardiac troponin immunoassay.
    Aloe R; Lippi G; Di Pietro M; Bonfanti L; Dipalo M; Comelli I; Avanzini P; Sanchis-Gomar F; Cervellin G
    Acta Biomed; 2019 Dec; 90(4):614-620. PubMed ID: 31910198
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of 99th percentile and reference change values of the hs-cTnI method using ADVIA Centaur XPT platform: A multicenter study.
    Clerico A; Masotti S; Musetti V; Ripoli A; Aloe R; Di Pietro M; Rizzardi S; Dittadi R; Carrozza C; Belloni L; Perrone M; Fasano T; Canovi S; de Santis A; Prontera C; Guiotto C; Cosseddu D; Migliardi M; Bernardini S
    Clin Chim Acta; 2019 Aug; 495():161-166. PubMed ID: 30978328
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.