These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 30910243)

  • 21. Retrograde intramedullary nailing of supracondylar femur fractures above total knee arthroplasty. A preliminary report of four cases.
    Jabczenski FF; Crawford M
    J Arthroplasty; 1995 Feb; 10(1):95-101. PubMed ID: 7730839
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Dorsal Screw Penetration With the Use of Volar Plating of Distal Radius Fractures: How Can You Best Detect?
    Hill BW; Shakir I; Cannada LK
    J Orthop Trauma; 2015 Oct; 29(10):e408-13. PubMed ID: 26402306
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [A comparison of a fluoroscopy-free mechanical targeting system and a free-hand technic for the placement of distal interlocking screws of tibial nails].
    Krettek C; Könemann B; Farouk O; Kromm A; Schandelamier P; Tscherne H
    Chirurg; 1997 Nov; 68(11):1194-201. PubMed ID: 9518215
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Tibial intramedullary nail distal interlocking screw placement: comparison of the free-hand versus distally-based targeting device techniques.
    Gugala Z; Nana A; Lindsey RW
    Injury; 2001 Dec; 32 Suppl 4():SD21-5. PubMed ID: 11812474
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A simple technique to remove a bent femoral intramedullary nail and broken interlocking screw.
    Sonanis SV; Lampard AL; Kamat N; Shaikh MR; Beard DJ
    J Trauma; 2007 Aug; 63(2):435-8. PubMed ID: 17693847
    [No Abstract]   [Full Text] [Related]  

  • 26. The use of one compared with two distal screws in the treatment of femoral shaft fractures with interlocking intramedullary nailing. A clinical and biomechanical analysis.
    Hajek PD; Bicknell HR; Bronson WE; Albright JA; Saha S
    J Bone Joint Surg Am; 1993 Apr; 75(4):519-25. PubMed ID: 8478381
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Distal targeting device for long Gamma nail(®). Monocentric observational study.
    Ehlinger M; Dillman G; Czekaj J; Adam P; Taglang G; Brinkert D; Schenck B; Di Marco A; Bonnomet F
    Orthop Traumatol Surg Res; 2013 Nov; 99(7):799-804. PubMed ID: 24095597
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Factors affecting the results of distal femoral fractures treated by retrograde intramedullary nailing.
    Kim JW; Oh CW; Kyung HS; Min WK; Yoon SH
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Nov; 23(11):1311-5. PubMed ID: 19968169
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Potential of increased risk of neurovascular injury using proximal interlocking screws of retrograde femoral nails in patients with acetabular fractures.
    Brown GA; Firoozbakhsh K; Summa CD
    J Orthop Trauma; 2001 Aug; 15(6):433-7. PubMed ID: 11514771
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Setscrew distal locking for intramedullary nails: a biomechanical study.
    Köse N; Günal I; Wang X; Athanasiou KA; Agrawal CM; Mabrey JD
    J Orthop Trauma; 2000 Aug; 14(6):414-9. PubMed ID: 11001415
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Infra-isthmal fracture is a risk factor for nonunion after femoral nailing: a case-control study.
    Watanabe Y; Takenaka N; Kobayashi M; Matsushita T
    J Orthop Sci; 2013 Jan; 18(1):76-80. PubMed ID: 23053587
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The Relationship of Multiplanar Distal and Uniplanar Proximal Interlocking Screws to Neurovascular Structures with the Depuy Synthes Humeral Nail-EX: An Anatomic Study.
    Steinmetz G; Tobey J; Skinner S; Hickerson L
    J Orthop Trauma; 2018 Aug; 32(8):e300-e303. PubMed ID: 30028795
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Femoral fracture malrotation caused by freehand versus navigated distal interlocking.
    Gardner MJ; Citak M; Kendoff D; Krettek C; Hüfner T
    Injury; 2008 Feb; 39(2):176-80. PubMed ID: 17888433
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A mechanical distal aiming device for distal locking in femoral nails.
    Krettek C; Könemann B; Miclau T; Kölbli R; Machreich T; Tscherne H
    Clin Orthop Relat Res; 1999 Jul; (364):267-75. PubMed ID: 10416417
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Sensitivity and Specificity of Skyline and Carpal Shoot-Through Fluoroscopic Views of Volar Plate Fixation of the Distal Radius: A Cadaveric Investigation of Dorsal Cortex Screw Penetration.
    Stoops TK; Santoni BG; Clark NM; Bauer AA; Shoji C; Schwartz-Fernandes F
    Hand (N Y); 2017 Nov; 12(6):551-556. PubMed ID: 29091485
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Influence of screw combination and nail materials in the stability of anterograde reamed intramedullary nail in distal femoral fractures.
    Gabarre S; Albareda J; Gracia L; Puértolas S; Ibarz E; Herrera A
    Injury; 2017 Nov; 48 Suppl 6():S47-S53. PubMed ID: 29162241
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Blocking screws: an adjunct to retrograde nailing for distal femoral shaft fractures.
    Gavaskar AS; Chowdary N
    J Orthop Surg (Hong Kong); 2013 Aug; 21(2):158-62. PubMed ID: 24014775
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biomechanical evaluation of interlocking lag screw design in intramedullary nailing of unstable pertrochanteric fractures.
    Hoffmann S; Paetzold R; Stephan D; Püschel K; Buehren V; Augat P
    J Orthop Trauma; 2013 Sep; 27(9):483-90. PubMed ID: 23860133
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Factors influencing interlocking screw failure in unreamed small diameter nails--a biomechanical study using a distal tibia fracture model.
    Weninger P; Schueller M; Jamek M; Stanzl-Tschegg S; Redl H; Tschegg EK
    Clin Biomech (Bristol, Avon); 2009 May; 24(4):379-84. PubMed ID: 19231049
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Retrograde versus antegrade nailing of femoral shaft fractures.
    Ricci WM; Bellabarba C; Evanoff B; Herscovici D; DiPasquale T; Sanders R
    J Orthop Trauma; 2001; 15(3):161-9. PubMed ID: 11265005
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.