BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

834 related articles for article (PubMed ID: 30912993)

  • 1. Understanding outcomes and toxicological aspects of second generation metal-on-metal hip implants: a state-of-the-art review.
    Kovochich M; Finley BL; Novick R; Monnot AD; Donovan E; Unice KM; Fung ES; Fung D; Paustenbach DJ
    Crit Rev Toxicol; 2018 Nov; 48(10):853-901. PubMed ID: 30912993
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Adverse Local Tissue Reactions are Common in Asymptomatic Individuals After Hip Resurfacing Arthroplasty: Interim Report from a Prospective Longitudinal Study.
    Koff MF; Gao MA; Neri JP; Chiu YF; Lin BQ; Burge AJ; Su E; Padgett DE; Potter HG
    Clin Orthop Relat Res; 2021 Dec; 479(12):2633-2650. PubMed ID: 34232144
    [TBL] [Abstract][Full Text] [Related]  

  • 3. What Is the Clinical Presentation of Adverse Local Tissue Reaction in Metal-on-metal Hip Arthroplasty? An MRI Study.
    Galea VP; Laaksonen I; Connelly JW; Matuszak SJ; Nortje M; Madanat R; Muratoglu O; Malchau H
    Clin Orthop Relat Res; 2019 Feb; 477(2):353-360. PubMed ID: 30794223
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation.
    Liow MHL; Kwon YM
    Int Orthop; 2017 May; 41(5):885-892. PubMed ID: 27761629
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Metal-on-Metal Total Hip Resurfacing Arthroplasty: An Evidence-Based Analysis.
    Medical Advisory Secretariat
    Ont Health Technol Assess Ser; 2006; 6(4):1-57. PubMed ID: 23074495
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High Revision Rate for Large-head Metal-on-metal THA at a Mean of 7.1 Years: A Registry Study.
    Seppänen M; Laaksonen I; Pulkkinen P; Eskelinen A; Puhto AP; Kettunen J; Leskinen J; Manninen M; Mäkelä K
    Clin Orthop Relat Res; 2018 Jun; 476(6):1223-1230. PubMed ID: 29480891
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Do patients with a failed metal-on-metal hip implant with a pseudotumor present differences in their peripheral blood lymphocyte subpopulations?
    Catelas I; Lehoux EA; Hurda I; Baskey SJ; Gala L; Foster R; Kim PR; Beaulé PE
    Clin Orthop Relat Res; 2015 Dec; 473(12):3903-14. PubMed ID: 26324830
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hip resurfacing arthroplasty in young patients: international high-volume centres' report on the outcome of 11,382 metal-on-metal hip resurfacing arthroplasties in patients ⩽50 years at surgery.
    Van Der Straeten C;
    Hip Int; 2022 May; 32(3):353-362. PubMed ID: 32905713
    [TBL] [Abstract][Full Text] [Related]  

  • 9. MRI of THA Correlates With Implant Wear and Tissue Reactions: A Cross-sectional Study.
    Koff MF; Esposito C; Shah P; Miranda M; Baral E; Fields K; Bauer T; Padgett DE; Wright T; Potter HG
    Clin Orthop Relat Res; 2019 Jan; 477(1):159-174. PubMed ID: 30499779
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Preoperative Risk Factors Associated With Poor Outcomes of Revision Surgery for "Pseudotumors" in Patients With Metal-on-Metal Hip Arthroplasty.
    Liow MH; Dimitriou D; Tsai TY; Kwon YM
    J Arthroplasty; 2016 Dec; 31(12):2835-2842. PubMed ID: 27387480
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Do retrieval analysis and blood metal measurements contribute to our understanding of adverse local tissue reactions?
    Campbell PA; Kung MS; Hsu AR; Jacobs JJ
    Clin Orthop Relat Res; 2014 Dec; 472(12):3718-27. PubMed ID: 25160942
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Higher Prevalence of Mixed or Solid Pseudotumors in Metal-on-Polyethylene Total Hip Arthroplasty Compared With Metal-on-Metal Total Hip Arthroplasty and Resurfacing Hip Arthroplasty.
    Hjorth MH; Mechlenburg I; Soballe K; Roemer L; Jakobsen SS; Stilling M
    J Arthroplasty; 2018 Jul; 33(7):2279-2286. PubMed ID: 29526334
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Outcomes of different bearings in total hip arthroplasty - implant survival, revision causes, and patient-reported outcome.
    Varnum C
    Dan Med J; 2017 Mar; 64(3):. PubMed ID: 28260601
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A prospective comparative study of hip resurfacing arthroplasty and large-diameter head metal-on-metal total hip arthroplasty in younger patients-a minimum of five year follow-up.
    Tao R; Liu F; Liu YK; Lu Y; Xu H; Cao Y; Zhou ZY; Wang W
    Int Orthop; 2018 Oct; 42(10):2323-2327. PubMed ID: 29455347
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Same survival but higher rate of osteolysis for metal-on-metal Ultamet versus ceramic-on-ceramic in patients undergoing primary total hip arthroplasty after 8 years of follow-up.
    Higuchi Y; Seki T; Takegami Y; Komatsu D; Morita D; Ishiguro N
    Orthop Traumatol Surg Res; 2018 Dec; 104(8):1155-1161. PubMed ID: 30269967
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Metal-on-metal hip resurfacing arthroplasty: an analysis of safety and revision rates.
    Sehatzadeh S; Kaulback K; Levin L
    Ont Health Technol Assess Ser; 2012; 12(19):1-63. PubMed ID: 23074429
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pleomorphic clinical spectrum of metallosis in total hip arthroplasty.
    Pisanu F; Doria C; Andreozzi M; Bartoli M; Saderi L; Sotgiu G; Tranquilli Leali P
    Int Orthop; 2019 Jan; 43(1):85-96. PubMed ID: 30269183
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Long-term survival of hybrid total hip arthroplasty with the uncemented CLS cup, cemented Müller cobalt-chromium stem, and 28-mm Metasul™ bearings: Retrospective review of 115 hips after a minimum of 17.8 years.
    Erivan R; Villatte G; Lecointe T; Mulliez A; Descamps S; Boisgard S
    Orthop Traumatol Surg Res; 2019 Nov; 105(7):1289-1295. PubMed ID: 31526707
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Outcome of revised metal-on-metal hip arthroplasties: a Dutch arthroplasty register study.
    Jelsma J; van Kuijk SMJ; Spekenbrink-Spooren A; Grimm B; Heyligers IC; Schotanus MGM
    Arch Orthop Trauma Surg; 2022 Dec; 142(12):4025-4032. PubMed ID: 34846589
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Catastrophic failure of femoral stem modular junction when combined with metal-on-metal bearing in comparison to ceramic-on-ceramic: A retrospective cohort study.
    Beauchamp JE; Vendittoli PA; Barry J; Pelet S; Belzile EL
    Orthop Traumatol Surg Res; 2021 Feb; 107(1):102749. PubMed ID: 33316446
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 42.