These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
267 related articles for article (PubMed ID: 30922312)
21. Ultrasound focusing using magnetic resonance acoustic radiation force imaging: application to ultrasound transcranial therapy. Hertzberg Y; Volovick A; Zur Y; Medan Y; Vitek S; Navon G Med Phys; 2010 Jun; 37(6):2934-42. PubMed ID: 20632605 [TBL] [Abstract][Full Text] [Related]
22. A High-Frequency Phased Array System for Transcranial Ultrasound Delivery in Small Animals. Rahimi S; Jones RM; Hynynen K IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Jan; 68(1):127-135. PubMed ID: 32746231 [TBL] [Abstract][Full Text] [Related]
24. Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice. Choi JJ; Pernot M; Small SA; Konofagou EE Ultrasound Med Biol; 2007 Jan; 33(1):95-104. PubMed ID: 17189051 [TBL] [Abstract][Full Text] [Related]
25. Design and Implementation of a Transmit/Receive Ultrasound Phased Array for Brain Applications. Liu HL; Tsai CH; Jan CK; Chang HY; Huang SM; Li ML; Qiu W; Zheng H IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Oct; 65(10):1756-1767. PubMed ID: 30010555 [TBL] [Abstract][Full Text] [Related]
26. Design of patient-specific focused ultrasound arrays for non-invasive brain therapy with increased trans-skull transmission and steering range. Hughes A; Hynynen K Phys Med Biol; 2017 Aug; 62(17):L9-L19. PubMed ID: 28665289 [TBL] [Abstract][Full Text] [Related]
28. Feasibility of using lateral mode coupling method for a large scale ultrasound phased array for noninvasive transcranial therapy. Song J; Hynynen K IEEE Trans Biomed Eng; 2010 Jan; 57(1):124-33. PubMed ID: 19695987 [TBL] [Abstract][Full Text] [Related]
29. Characterization of different bubble formulations for blood-brain barrier opening using a focused ultrasound system with acoustic feedback control. Bing C; Hong Y; Hernandez C; Rich M; Cheng B; Munaweera I; Szczepanski D; Xi Y; Bolding M; Exner A; Chopra R Sci Rep; 2018 May; 8(1):7986. PubMed ID: 29789589 [TBL] [Abstract][Full Text] [Related]
30. Characterization of weakly nonlinear effects in relationship to transducer parameters in focused ultrasound therapy. Xu P; Wu H; Shen G Med Phys; 2024 Oct; 51(10):7619-7631. PubMed ID: 38935266 [TBL] [Abstract][Full Text] [Related]
31. A multi-frequency sparse hemispherical ultrasound phased array for microbubble-mediated transcranial therapy and simultaneous cavitation mapping. Deng L; O'Reilly MA; Jones RM; An R; Hynynen K Phys Med Biol; 2016 Dec; 61(24):8476-8501. PubMed ID: 27845920 [TBL] [Abstract][Full Text] [Related]
32. Cavitation-enhanced nonthermal ablation in deep brain targets: feasibility in a large animal model. Arvanitis CD; Vykhodtseva N; Jolesz F; Livingstone M; McDannold N J Neurosurg; 2016 May; 124(5):1450-9. PubMed ID: 26381252 [TBL] [Abstract][Full Text] [Related]
33. Ultrashort echo-time MRI versus CT for skull aberration correction in MR-guided transcranial focused ultrasound: In vitro comparison on human calvaria. Miller GW; Eames M; Snell J; Aubry JF Med Phys; 2015 May; 42(5):2223-33. PubMed ID: 25979016 [TBL] [Abstract][Full Text] [Related]
34. An MRI-compatible system for focused ultrasound experiments in small animal models. Chopra R; Curiel L; Staruch R; Morrison L; Hynynen K Med Phys; 2009 May; 36(5):1867-74. PubMed ID: 19544806 [TBL] [Abstract][Full Text] [Related]
35. Trans-cranial opening of the blood-brain barrier in targeted regions using a stereotaxic brain atlas and focused ultrasound energy. Bing C; Ladouceur-Wodzak M; Wanner CR; Shelton JM; Richardson JA; Chopra R J Ther Ultrasound; 2014; 2():13. PubMed ID: 25232482 [TBL] [Abstract][Full Text] [Related]
36. Design and experimental evaluations of a low-frequency hemispherical ultrasound phased-array system for transcranial blood-brain barrier disruption. Liu HL; Chen HW; Kuo ZH; Huang WC IEEE Trans Biomed Eng; 2008 Oct; 55(10):2407-16. PubMed ID: 18838366 [TBL] [Abstract][Full Text] [Related]
37. An image-guided high intensity focused ultrasound device for uterine fibroids treatment. Chan AH; Fujimoto VY; Moore DE; Martin RW; Vaezy S Med Phys; 2002 Nov; 29(11):2611-20. PubMed ID: 12462728 [TBL] [Abstract][Full Text] [Related]
38. In Vivo application and localization of transcranial focused ultrasound using dual-mode ultrasound arrays. Haritonova A; Liu D; Ebbini ES IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Dec; 62(12):2031-42. PubMed ID: 26670845 [TBL] [Abstract][Full Text] [Related]
39. A 200-1380-kHz Quadrifrequency Focused Ultrasound Transducer for Neurostimulation in Rodents and Primates: Transcranial In Vitro Calibration and Numerical Study of the Influence of Skull Cavity. Constans C; Deffieux T; Pouget P; Tanter M; Aubry JF IEEE Trans Ultrason Ferroelectr Freq Control; 2017 Apr; 64(4):717-724. PubMed ID: 28092531 [TBL] [Abstract][Full Text] [Related]
40. Treatment of near-skull brain tissue with a focused device using shear-mode conversion: a numerical study. Pichardo S; Hynynen K Phys Med Biol; 2007 Dec; 52(24):7313-32. PubMed ID: 18065841 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]