269 related articles for article (PubMed ID: 30924210)
1. A comparison of static and dynamic ∆B
Poblador Rodriguez E; Moser P; Dymerska B; Robinson S; Schmitt B; van der Kouwe A; Gruber S; Trattnig S; Bogner W
Magn Reson Med; 2019 Aug; 82(2):633-646. PubMed ID: 30924210
[TBL] [Abstract][Full Text] [Related]
2. Simultaneous pH-sensitive and oxygen-sensitive MRI of human gliomas at 3 T using multi-echo amine proton chemical exchange saturation transfer spin-and-gradient echo echo-planar imaging (CEST-SAGE-EPI).
Harris RJ; Yao J; Chakhoyan A; Raymond C; Leu K; Liau LM; Nghiemphu PL; Lai A; Salamon N; Pope WB; Cloughesy TF; Ellingson BM
Magn Reson Med; 2018 Nov; 80(5):1962-1978. PubMed ID: 29626359
[TBL] [Abstract][Full Text] [Related]
3. Frequency-stabilized chemical exchange saturation transfer imaging with real-time free-induction-decay readout.
Liu R; Zhang H; Qian Y; Hsu YC; Fu C; Sun Y; Wu D; Zhang Y
Magn Reson Med; 2021 Mar; 85(3):1322-1334. PubMed ID: 32970882
[TBL] [Abstract][Full Text] [Related]
4. Improved chemical exchange saturation transfer imaging with real-time frequency drift correction.
Liu R; Zhang H; Niu W; Lai C; Ding Q; Chen W; Liang S; Zhou J; Wu D; Zhang Y
Magn Reson Med; 2019 May; 81(5):2915-2923. PubMed ID: 30697813
[TBL] [Abstract][Full Text] [Related]
5. Chemical exchange saturation transfer MR imaging of articular cartilage glycosaminoglycans at 3 T: Accuracy of B0 Field Inhomogeneity corrections with gradient echo method.
Wei W; Jia G; Flanigan D; Zhou J; Knopp MV
Magn Reson Imaging; 2014 Jan; 32(1):41-7. PubMed ID: 24119460
[TBL] [Abstract][Full Text] [Related]
6. Real-time motion and retrospective coil sensitivity correction for CEST using volumetric navigators (vNavs) at 7T.
Poblador Rodriguez E; Moser P; Auno S; Eckstein K; Dymerska B; van der Kouwe A; Gruber S; Trattnig S; Bogner W
Magn Reson Med; 2021 Apr; 85(4):1909-1923. PubMed ID: 33165952
[TBL] [Abstract][Full Text] [Related]
7. Systematic Evaluation of Amide Proton Chemical Exchange Saturation Transfer at 3 T: Effects of Protein Concentration, pH, and Acquisition Parameters.
Schmidt H; Schwenzer NF; Gatidis S; Küstner T; Nikolaou K; Schick F; Martirosian P
Invest Radiol; 2016 Oct; 51(10):635-46. PubMed ID: 27272542
[TBL] [Abstract][Full Text] [Related]
8. Whole-brain chemical exchange saturation transfer imaging with optimized turbo spin echo readout.
Zhang Y; Yong X; Liu R; Tang J; Jiang H; Fu C; Wei R; Hsu YC; Sun Y; Luo B; Wu D
Magn Reson Med; 2020 Sep; 84(3):1161-1172. PubMed ID: 32011026
[TBL] [Abstract][Full Text] [Related]
9. Assessment of frequency drift on CEST MRI and dynamic correction: application to gagCEST at 7 T.
Windschuh J; Zaiss M; Ehses P; Lee JS; Jerschow A; Regatte RR
Magn Reson Med; 2019 Jan; 81(1):573-582. PubMed ID: 29851141
[TBL] [Abstract][Full Text] [Related]
10. Characterization of B
Shrestha Kakkar L; Usman M; Arridge S; Kirkham A; Atkinson D
Phys Med Biol; 2020 Nov; 65(21):21NT01. PubMed ID: 32992306
[TBL] [Abstract][Full Text] [Related]
11. Simplified assessment for chemical exchanged saturation transfer (CEST) imaging: local offset frequency and CEST effect.
Chiba D; Kanazawa Y; Miyati T; Harada M; Miyoshi M; Hayashi H; Haga A
Radiol Phys Technol; 2024 Mar; 17(1):93-102. PubMed ID: 37897684
[TBL] [Abstract][Full Text] [Related]
12. Improved postprocessing of dynamic glucose-enhanced CEST MRI for imaging brain metastases at 3 T.
Wu Y; Derks SHAE; Wood TC; de Blois E; van der Veldt AAM; Smits M; Warnert EAH
Eur Radiol Exp; 2023 Dec; 7(1):78. PubMed ID: 38066225
[TBL] [Abstract][Full Text] [Related]
13. Improvement of water saturation shift referencing by sequence and analysis optimization to enhance chemical exchange saturation transfer imaging.
Müller-Lutz A; Matuschke F; Schleich C; Wickrath F; Boos J; Schmitt B; Wittsack HJ
Magn Reson Imaging; 2016 Jul; 34(6):771-778. PubMed ID: 26988704
[TBL] [Abstract][Full Text] [Related]
14. 3D gradient echo snapshot CEST MRI with low power saturation for human studies at 3T.
Deshmane A; Zaiss M; Lindig T; Herz K; Schuppert M; Gandhi C; Bender B; Ernemann U; Scheffler K
Magn Reson Med; 2019 Apr; 81(4):2412-2423. PubMed ID: 30431179
[TBL] [Abstract][Full Text] [Related]
15. Dynamic B0 shimming at 7 T.
Sengupta S; Welch EB; Zhao Y; Foxall D; Starewicz P; Anderson AW; Gore JC; Avison MJ
Magn Reson Imaging; 2011 May; 29(4):483-96. PubMed ID: 21398062
[TBL] [Abstract][Full Text] [Related]
16. A method for the dynamic correction of B
Dymerska B; Poser BA; Barth M; Trattnig S; Robinson SD
Neuroimage; 2018 Mar; 168():321-331. PubMed ID: 27397624
[TBL] [Abstract][Full Text] [Related]
17. B
Nöth U; Shrestha M; Deichmann R
Magn Reson Med; 2023 Jul; 90(1):103-116. PubMed ID: 36912496
[TBL] [Abstract][Full Text] [Related]
18. Improving B
Yao J; Ruan D; Raymond C; Liau LM; Salamon N; Pope WB; Nghiemphu PL; Lai A; Cloughesy TF; Ellingson BM
Tomography; 2018 Sep; 4(3):123-137. PubMed ID: 30320212
[TBL] [Abstract][Full Text] [Related]
19. Dynamic field mapping and distortion correction using single-shot blip-rewound EPI and joint multi-echo reconstruction.
Wu W
Magn Reson Med; 2024 Jul; 92(1):82-97. PubMed ID: 38308081
[TBL] [Abstract][Full Text] [Related]
20. Amide proton transfer imaging of brain tumors using a self-corrected 3D fast spin-echo dixon method: Comparison With separate B
Togao O; Keupp J; Hiwatashi A; Yamashita K; Kikuchi K; Yoneyama M; Honda H
Magn Reson Med; 2017 Jun; 77(6):2272-2279. PubMed ID: 27385636
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]