130 related articles for article (PubMed ID: 30928071)
1. Analytical simulator of proton radiography and tomography for different detector configurations.
Gianoli C; Meyer S; Magallanes L; Paganelli C; Baroni G; Parodi K
Phys Med; 2019 Mar; 59():92-99. PubMed ID: 30928071
[TBL] [Abstract][Full Text] [Related]
2. Patient-specific CT calibration based on ion radiography for different detector configurations in
Gianoli C; Göppel M; Meyer S; Palaniappan P; Rädler M; Kamp F; Belka C; Riboldi M; Parodi K
Phys Med Biol; 2020 Dec; 65(24):245014. PubMed ID: 32629442
[TBL] [Abstract][Full Text] [Related]
3. Image quality of list-mode proton imaging without front trackers.
Rambo Sølie J; Volz L; Egil Seime Pettersen H; Piersimoni P; Harald Odland O; Röhrich D; Helstrup H; Peitzmann T; Ullaland K; Varga-Kofarago M; Mehendale S; Slettevoll Grøttvik O; Nilsen Eikeland V; Meric I; Seco J
Phys Med Biol; 2020 Jul; 65(13):135012. PubMed ID: 32344385
[TBL] [Abstract][Full Text] [Related]
4. Deformable image registration of the treatment planning CT with proton radiographies in perspective of adaptive proton therapy.
Palaniappan P; Meyer S; Kamp F; Belka C; Riboldi M; Parodi K; Gianoli C
Phys Med Biol; 2021 Feb; 66(4):045008. PubMed ID: 32365335
[TBL] [Abstract][Full Text] [Related]
5. A pencil beam approach to proton computed tomography.
Rescigno R; Bopp C; Rousseau M; Brasse D
Med Phys; 2015 Nov; 42(11):6610-24. PubMed ID: 26520752
[TBL] [Abstract][Full Text] [Related]
6. Comparative Monte Carlo study on the performance of integration- and list-mode detector configurations for carbon ion computed tomography.
Meyer S; Gianoli C; Magallanes L; Kopp B; Tessonnier T; Landry G; Dedes G; Voss B; Parodi K
Phys Med Biol; 2017 Feb; 62(3):1096-1112. PubMed ID: 28092630
[TBL] [Abstract][Full Text] [Related]
7. Polynomial modelling of proton trajectories in homogeneous media for fast most likely path estimation and trajectory simulation.
Krah N; Létang JM; Rit S
Phys Med Biol; 2019 Oct; 64(19):195014. PubMed ID: 31430724
[TBL] [Abstract][Full Text] [Related]
8. An inhomogeneous most likely path formalism for proton computed tomography.
Brooke MD; Penfold SN
Phys Med; 2020 Feb; 70():184-195. PubMed ID: 32036335
[TBL] [Abstract][Full Text] [Related]
9. A maximum likelihood method for high resolution proton radiography/proton CT.
Collins-Fekete CA; Brousmiche S; Portillo SK; Beaulieu L; Seco J
Phys Med Biol; 2016 Dec; 61(23):8232-8248. PubMed ID: 27811399
[TBL] [Abstract][Full Text] [Related]
10. The optimal balance between quality and efficiency in proton radiography imaging technique at various proton beam energies: A Monte Carlo study.
Biegun AK; van Goethem MJ; van der Graaf ER; van Beuzekom M; Koffeman EN; Nakaji T; Takatsu J; Visser J; Brandenburg S
Phys Med; 2017 Sep; 41():141-146. PubMed ID: 28869137
[TBL] [Abstract][Full Text] [Related]
11. Feasibility of energy-resolved dose imaging technique in pencil beam scanning mode.
Alaka BG; Bentefour EH; Chirvase C; Samuel D; Teo BK
Biomed Phys Eng Express; 2020 Sep; 6(6):. PubMed ID: 35102004
[No Abstract] [Full Text] [Related]
12. Reconstruction for proton computed tomography by tracing proton trajectories: a Monte Carlo study.
Li T; Liang Z; Singanallur JV; Satogata TJ; Williams DC; Schulte RW
Med Phys; 2006 Mar; 33(3):699-706. PubMed ID: 16878573
[TBL] [Abstract][Full Text] [Related]
13. Extension of the Fermi-Eyges most-likely path in heterogeneous medium with prior knowledge information.
Collins-Fekete CA; Bär E; Volz L; Bouchard H; Beaulieu L; Seco J
Phys Med Biol; 2017 Nov; 62(24):9207-9219. PubMed ID: 29059051
[TBL] [Abstract][Full Text] [Related]
14. The impact of path estimates in iterative ion CT reconstructions for clinical-like cases.
Meyer S; Pinto M; Parodi K; Gianoli C
Phys Med Biol; 2021 Apr; 66(9):. PubMed ID: 33765672
[TBL] [Abstract][Full Text] [Related]
15. Energy-adaptive calculation of the most likely path in proton CT.
Krah N; Dauvergne D; Létang JM; Rit S; Testa É
Phys Med Biol; 2021 Oct; 66(20):. PubMed ID: 34555825
[TBL] [Abstract][Full Text] [Related]
16. Scattering proton CT.
Krah N; Quiñones CT; Létang JM; Rit S
Phys Med Biol; 2020 Nov; 65(22):225015. PubMed ID: 32998114
[TBL] [Abstract][Full Text] [Related]
17. Experimental comparison of clinically used ion beams for imaging applications using a range telescope.
Kopp B; Meyer S; Gianoli C; Magallanes L; Voss B; Brons S; Parodi K
Phys Med Biol; 2020 Jul; 65(15):155004. PubMed ID: 32268309
[TBL] [Abstract][Full Text] [Related]
18. Optimization and performance study of a proton CT system for pre-clinical small animal imaging.
Meyer S; Bortfeldt J; Lämmer P; Englbrecht FS; Pinto M; Schnürle K; Würl M; Parodi K
Phys Med Biol; 2020 Aug; 65(15):155008. PubMed ID: 32311690
[TBL] [Abstract][Full Text] [Related]
19. Proton path reconstruction for proton computed tomography using neural networks.
Ackernley T; Casse G; Cristoforetti M
Phys Med Biol; 2021 Apr; 66(7):. PubMed ID: 33735852
[TBL] [Abstract][Full Text] [Related]
20. Pre-treatment patient-specific stopping power by combining list-mode proton radiography and x-ray CT.
Collins-Fekete CA; Brousmiche S; Hansen DC; Beaulieu L; Seco J
Phys Med Biol; 2017 Aug; 62(17):6836-6852. PubMed ID: 28657550
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]