These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

69 related articles for article (PubMed ID: 30934038)

  • 21. Clinical Evaluation of Two Distinct Materials for Implant-Supported Interim Fixed Partial Prostheses: An Original Research.
    Sravanthi D; Duseja S; Mansoor MA; Abdul HN; Anjan T; Balaji DL; Tiwari RVC
    J Pharm Bioallied Sci; 2024 Feb; 16(Suppl 1):S651-S654. PubMed ID: 38595414
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effects of multiple implantations of titanium healing abutments: Surface characteristics and microbial colonization.
    Jain SS; Schramm STJ; Siddiqui DA; Huo W; Palmer KL; Wilson TG; Rodrigues DC
    Dent Mater; 2020 Sep; 36(9):e279-e291. PubMed ID: 32591158
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Concepts for prevention of complications in implant therapy.
    Romanos GE; Delgado-Ruiz R; Sculean A
    Periodontol 2000; 2019 Oct; 81(1):7-17. PubMed ID: 31407435
    [TBL] [Abstract][Full Text] [Related]  

  • 24. SEM Analysis and Micro-CT Evaluation of Four Dental Implants after Three Different Mechanical Requests-In Vitro Study.
    Vinhas AS; Salazar F; Mendes JM; Silva AS; Ríos-Carrasco B; Ríos-Santos JV; Gil J; Herrero-Climent M; Aroso C
    Materials (Basel); 2024 Jan; 17(2):. PubMed ID: 38255602
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The Effect of a 10-MDP-Based Dentin Adhesive as Alternative for Bonding to Implant Abutment Materials.
    Carvalho PCK; Almeida CCMS; Souza ROA; Tango RN
    Materials (Basel); 2022 Aug; 15(15):. PubMed ID: 35955383
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Risk Indicators Affecting the Survival of the Mandibular First Molar Adjacent to an Implant at the Mandibular Second Molar Site: A Retrospective Study.
    Park WB; Kwon KH; Hwang KG; Han JY
    J Clin Med; 2021 Jun; 10(12):. PubMed ID: 34201316
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Mechanical Pull-Out Test of a New Hybrid Fixture-Abutment Connection: An In Vitro Study.
    D'Addazio G; Sinjari B; Arcuri L; Femminella B; Murmura G; Santilli M; Caputi S
    Materials (Basel); 2021 Mar; 14(6):. PubMed ID: 33810040
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Axial Displacements and Removal Torque Changes of Five Different Implant-Abutment Connections under Static Vertical Loading.
    Kim KS; Lim YJ
    Materials (Basel); 2020 Feb; 13(3):. PubMed ID: 32033105
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Mechanical behavior of titanium and zirconia abutments at the implant-abutment interface: A systematic review.
    de Holanda Cavalcanti Pereira AK; de Oliveira Limirio JPJ; Cavalcanti do Egito Vasconcelos B; Pellizzer EP; Dantas de Moraes SL
    J Prosthet Dent; 2024 Mar; 131(3):420-426. PubMed ID: 35292155
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Zirconia abutments in the anterior region: A systematic review of mechanical and esthetic outcomes.
    Naveau A; Rignon-Bret C; Wulfman C
    J Prosthet Dent; 2019 May; 121(5):775-781.e1. PubMed ID: 30617036
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Axial displacement in cement-retained prostheses with different implant-abutment connections.
    Ko KH; Huh YH; Park CJ; Cho LR
    Int J Oral Maxillofac Implants; 2019; 34(5):1098–1104. PubMed ID: 30934038
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Precision of the Connection Between Implant and Standard or Computer-Aided Design/Computer-Aided Manufacturing Abutments: A Novel Evaluation Method.
    Lops D; Meneghello R; Sbricoli L; Savio G; Bressan E; Stellini E
    Int J Oral Maxillofac Implants; 2018; 33(1):23-30. PubMed ID: 29340342
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Mechanical stability of fully personalized, abutment-free zirconia implant crowns on a novel implant-crown interface.
    Hjerppe J; Jung RE; Hämmerle CH; Özcan M; Mühlemann S
    J Dent; 2022 Jun; 121():104121. PubMed ID: 35395344
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Influence of margin location and luting material on the amount of undetected cement excess on CAD/CAM implant abutments and cement-retained zirconia crowns: an in-vitro study.
    Gehrke P; Bleuel K; Fischer C; Sader R
    BMC Oral Health; 2019 Jun; 19(1):111. PubMed ID: 31200680
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Retention of CAD/CAM all-ceramic crowns on prefabricated implant abutments: an in vitro comparative study of luting agents and abutment surface area.
    Carnaggio TV; Conrad R; Engelmeier RL; Gerngross P; Paravina R; Perezous L; Powers JM
    J Prosthodont; 2012 Oct; 21(7):523-8. PubMed ID: 22469271
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Displacement comparison of CAD-CAM titanium and zirconia abutments to implants with different conical connections.
    Yilmaz B; Hashemzadeh S; Seidt JD; Clelland NL
    J Prosthodont Res; 2018 Apr; 62(2):200-203. PubMed ID: 28888428
    [TBL] [Abstract][Full Text] [Related]  

  • 37.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 38.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 39.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 40.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.