These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

254 related articles for article (PubMed ID: 30934688)

  • 1. Surface Modification of Ti-6Al-4V Alloy by Electrical Discharge Coating Process Using Partially Sintered Ti-Nb Electrode.
    Prakash C; Singh S; Pruncu CI; Mishra V; Królczyk G; Pimenov DY; Pramanik A
    Materials (Basel); 2019 Mar; 12(7):. PubMed ID: 30934688
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wear studies on plasma-sprayed Al2O3 and 8mole% of Yttrium-stabilized ZrO2 composite coating on biomedical Ti-6Al-4V alloy for orthopedic joint application.
    Ganapathy P; Manivasagam G; Rajamanickam A; Natarajan A
    Int J Nanomedicine; 2015; 10 Suppl 1(Suppl 1):213-22. PubMed ID: 26491323
    [TBL] [Abstract][Full Text] [Related]  

  • 3. On the machinability and properties of Ti-6Al-4V biomaterial with n-HAp powder-mixed ED machining.
    Bains PS; Bahraminasab M; Sidhu SS; Singh G
    Proc Inst Mech Eng H; 2020 Feb; 234(2):232-242. PubMed ID: 31804148
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Enhanced wear and fatigue properties of Ti-6Al-4V alloy modified by plasma carburizing/CrN coating.
    Park YG; Wey MY; Hong SI
    J Mater Sci Mater Med; 2007 May; 18(5):925-31. PubMed ID: 17143738
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Processing Characteristics of Micro Electrical Discharge Machining for Surface Modification of TiNi Shape Memory Alloys Using a TiC Powder Dielectric.
    Zhu Z; Guo D; Xu J; Lin J; Lei J; Xu B; Wu X; Wang X
    Micromachines (Basel); 2020 Nov; 11(11):. PubMed ID: 33233683
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Data related to optimized process parameters influence on hardness, microstructural evolution and wear resistance performance of Al-Si-Sn-Cu/Ti-6Al-4V composite coatings.
    Fatoba OS; Akinlabi ET; Akinlabi SA; Obiegbu MC
    Data Brief; 2019 Apr; 23():103724. PubMed ID: 31372392
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Tribological Properties of Ni/Cu/Ni Coating on the Ti-6Al-4V Alloy after Annealing at Various Temperatures.
    Luo J; Wang N; Zhu L; Wu G; Li L; Yang M; Zhang L; Chen Y
    Materials (Basel); 2020 Feb; 13(4):. PubMed ID: 32069841
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Osteoblastic behavior to zirconium coating on Ti-6Al-4V alloy.
    Lee BA; Kim HJ; Xuan YZ; Park YJ; Chung HJ; Kim YJ
    J Adv Prosthodont; 2014 Dec; 6(6):512-20. PubMed ID: 25551012
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Laser surface modification of Ti--6Al--4V: wear and corrosion characterization in simulated biofluid.
    Singh R; Kurella A; Dahotre NB
    J Biomater Appl; 2006 Jul; 21(1):49-73. PubMed ID: 16443617
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Functionally graded Co-Cr-Mo coating on Ti-6Al-4V alloy structures.
    Vamsi Krishna B; Xue W; Bose S; Bandyopadhyay A
    Acta Biomater; 2008 May; 4(3):697-706. PubMed ID: 18054298
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Microstructure and mechanical properties of plasma sprayed HA/YSZ/Ti-6Al-4V composite coatings.
    Khor KA; Gu YW; Pan D; Cheang P
    Biomaterials; 2004 Aug; 25(18):4009-17. PubMed ID: 15046891
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mechano-tribological properties and in vitro bioactivity of biphasic calcium phosphate coating on Ti-6Al-4V.
    Behera RR; Das A; Pamu D; Pandey LM; Sankar MR
    J Mech Behav Biomed Mater; 2018 Oct; 86():143-157. PubMed ID: 29986289
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fatigue properties of carbon- and porous-coated Ti-6Al-4V alloy.
    Cook SD; Georgette FS; Skinner HB; Haddad RJ
    J Biomed Mater Res; 1984; 18(5):497-512. PubMed ID: 6736080
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of Tricalcium Magnesium Silicate Coating on the Electrochemical and Biological Behavior of Ti-6Al-4V Alloys.
    Maleki-Ghaleh H; Hafezi M; Hadipour M; Nadernezhad A; Aghaie E; Behnamian Y; Abu Osman NA
    PLoS One; 2015; 10(9):e0138454. PubMed ID: 26383641
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fabrication of dense α-alumina layer on Ti-6Al-4V alloy hybrid for bearing surfaces of artificial hip joint.
    Khanna R; Kokubo T; Matsushita T; Takadama H
    Mater Sci Eng C Mater Biol Appl; 2016 Dec; 69():1229-39. PubMed ID: 27612821
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of Al Content on the Wear Evolution of Ti
    Fan G; Zhang J; Zhang P; Du J; Xu C; Yi M; Zhang G
    Micromachines (Basel); 2023 Jun; 14(6):. PubMed ID: 37374813
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cutting Performance of Different Coated Micro End Mills in Machining of Ti-6Al-4V.
    Liang Z; Gao P; Wang X; Li S; Zhou T; Xiang J
    Micromachines (Basel); 2018 Nov; 9(11):. PubMed ID: 30715067
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Enhancing Corrosion and Wear Resistance of Ti6Al4V Alloy Using CNTs Mixed Electro-Discharge Process.
    Singh G; Ablyaz TR; Shlykov ES; Muratov KR; Bhui AS; Sidhu SS
    Micromachines (Basel); 2020 Sep; 11(9):. PubMed ID: 32932735
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quantification of Microstructural Features and Prediction of Mechanical Properties of a Dual-Phase Ti-6Al-4V Alloy.
    Yang D; Liu Z
    Materials (Basel); 2016 Jul; 9(8):. PubMed ID: 28773751
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mesoporous Bioactive Glass Functionalized 3D Ti-6Al-4V Scaffolds with Improved Surface Bioactivity.
    Ye X; Leeflang S; Wu C; Chang J; Zhou J; Huan Z
    Materials (Basel); 2017 Oct; 10(11):. PubMed ID: 29077014
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.