These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

283 related articles for article (PubMed ID: 30935068)

  • 1. A Guided Wave Transducer with Sprayed Magnetostrictive Powder Coating for Monitoring of Aluminum Conductor Steel-Reinforced Cables.
    Lv F; Zhang P; Tang Z; Yue Y; Yang K
    Sensors (Basel); 2019 Mar; 19(7):. PubMed ID: 30935068
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Increased range of ultrasonic guided wave testing of overhead transmission line cables using dispersion compensation.
    Legg M; Yücel MK; Kappatos V; Selcuk C; Gan TH
    Ultrasonics; 2015 Sep; 62():35-45. PubMed ID: 25991388
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A magnetic flux leakage and magnetostrictive guided wave hybrid transducer for detecting bridge cables.
    Xu J; Wu X; Cheng C; Ben A
    Sensors (Basel); 2012; 12(1):518-33. PubMed ID: 22368483
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Study and comparison of different EMAT configurations for SH wave inspection.
    Ribichini R; Cegla F; Nagy PB; Cawley P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Dec; 58(12):2571-81. PubMed ID: 23443693
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Torsional wave experiments with a new magnetostrictive transducer configuration.
    Kim YY; Park CI; Cho SH; Han SW
    J Acoust Soc Am; 2005 Jun; 117(6):3459-68. PubMed ID: 16018450
    [TBL] [Abstract][Full Text] [Related]  

  • 6. New Magnetostrictive Transducer Designs for Emerging Application Areas of NDE.
    Vinogradov S; Cobb A; Fisher J
    Materials (Basel); 2018 May; 11(5):. PubMed ID: 29738482
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Circumferential phased array of shear-horizontal wave magnetostrictive patch transducers for pipe inspection.
    Kim HW; Lee JK; Kim YY
    Ultrasonics; 2013 Feb; 53(2):423-31. PubMed ID: 22925267
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Selection of Shear Horizontal Wave Transducers for Robotic Nondestructive Inspection in Harsh Environments.
    Choi S; Cho H; Lissenden CJ
    Sensors (Basel); 2016 Dec; 17(1):. PubMed ID: 28025508
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Investigation of the interwire energy transfer of elastic guided waves inside prestressed cables.
    Treyssède F
    J Acoust Soc Am; 2016 Jul; 140(1):498. PubMed ID: 27475173
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantitative modeling of the transduction of electromagnetic acoustic transducers operating on ferromagnetic media.
    Ribichini R; Cegla F; Nagy PB; Cawley P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Dec; 57(12):2808-17. PubMed ID: 21156376
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of the Spatial Dimensions of Ultrasonic Transducers on the Frequency Spectrum of Guided Waves.
    Samaitis V; Mažeika L
    Sensors (Basel); 2017 Aug; 17(8):. PubMed ID: 28786924
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A tunable bidirectional SH wave transducer based on antiparallel thickness-shear (d
    Chen M; Huan Q; Su Z; Li F
    Ultrasonics; 2019 Sep; 98():35-50. PubMed ID: 31176913
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Studies on the Evolution of Fatigue Strength of Aluminium Wires for Overhead Line Conductors.
    Jurkiewicz B; Smyrak B
    Materials (Basel); 2024 May; 17(11):. PubMed ID: 38893802
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A combination of PZT and EMAT transducers for interface inspection.
    Na WB; Kundu T
    J Acoust Soc Am; 2002 May; 111(5 Pt 1):2128-39. PubMed ID: 12051433
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a Novel Guided Wave Generation System Using a Giant Magnetostrictive Actuator for Nondestructive Evaluation.
    Luo M; Li W; Wang J; Wang N; Chen X; Song G
    Sensors (Basel); 2018 Mar; 18(3):. PubMed ID: 29510540
    [TBL] [Abstract][Full Text] [Related]  

  • 16. State-of-the-Art and Practical Guide to Ultrasonic Transducers for Harsh Environments Including Temperatures above 2120 °F (1000 °C) and Neutron Flux above 10
    Tittmann BR; Batista CFG; Trivedi YP; Lissenden Iii CJ; Reinhardt BT
    Sensors (Basel); 2019 Nov; 19(21):. PubMed ID: 31683921
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detecting broken-wire flaws at multiple locations in the same wire of prestressing strands using guided waves.
    Xu J; Wu X; Sun P
    Ultrasonics; 2013 Jan; 53(1):150-6. PubMed ID: 22658860
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Helical comb magnetostrictive patch transducers for inspecting spiral welded pipes using flexural guided waves.
    Zhang X; Tang Z; Lv F; Pan X
    Ultrasonics; 2017 Feb; 74():1-10. PubMed ID: 27718376
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 2D Analytical Model for the Directivity Prediction of Ultrasonic Contact Type Transducers in the Generation of Guided Waves.
    Tiwari KA; Raisutis R; Mazeika L; Samaitis V
    Sensors (Basel); 2018 Mar; 18(4):. PubMed ID: 29587472
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of an omni-directional shear-horizontal wave magnetostrictive patch transducer for plates.
    Seung HM; Kim HW; Kim YY
    Ultrasonics; 2013 Sep; 53(7):1304-8. PubMed ID: 23618078
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.