  • 21. Magnet dislocation following magnetic resonance imaging in cochlear implant users: Diagnostic pathways and managment.
    Holtmann L; Hans S; Kaster F; Müller V; Lang S; Göricke S; Lang-Roth R; Arweiler-Harbeck D
    Cochlear Implants Int; 2021 Jul; 22(4):195-202. PubMed ID: 33576730
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Adverse events in pediatric cochlear implant patients undergoing magnetic resonance imaging.
    Gallant SC; Danehy AR; Licameli GR
    Int J Pediatr Otorhinolaryngol; 2021 Jan; 140():110547. PubMed ID: 33310425
    [TBL] [Abstract][Full Text] [Related]  

  • 23. MRI without magnet removal in neurofibromatosis type 2 patients with cochlear and auditory brainstem implants.
    Walton J; Donnelly NP; Tam YC; Joubert I; Durie-Gair J; Jackson C; Mannion RA; Tysome JR; Axon PR; Scoffings DJ
    Otol Neurotol; 2014 Jun; 35(5):821-5. PubMed ID: 24608375
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Magnetic resonance imaging with cochlear implants and auditory brainstem implants: Are we truly practicing MRI safety?
    Shew M; Wichova H; Lin J; Ledbetter LN; Staecker H
    Laryngoscope; 2019 Feb; 129(2):482-489. PubMed ID: 30412276
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Dislocation of cochlear implant magnet as a complication following MRI.
    Murtojärvi S; Salonen J
    Duodecim; 2017; 133(5):497-500. PubMed ID: 29206000
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Adverse events and discomfort during magnetic resonance imaging in cochlear implant recipients.
    Kim BG; Kim JW; Park JJ; Kim SH; Kim HN; Choi JY
    JAMA Otolaryngol Head Neck Surg; 2015 Jan; 141(1):45-52. PubMed ID: 25411817
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Magnetic resonance imaging and cochlear implants: compatibility and safety aspects.
    Teissl C; Kremser C; Hochmair ES; Hochmair-Desoyer IJ
    J Magn Reson Imaging; 1999 Jan; 9(1):26-38. PubMed ID: 10030647
    [TBL] [Abstract][Full Text] [Related]  

  • 28. MRI-induced artifact by a cochlear implant with a novel magnet system: an experimental cadaver study.
    Canzi P; Aprile F; Simoncelli A; Manfrin M; Magnetto M; Lafe E; Minervini D; Avato I; Terrani S; Scribante A; Gazibegovic D; Benazzo M
    Eur Arch Otorhinolaryngol; 2021 Oct; 278(10):3753-3762. PubMed ID: 33206227
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A Prospective Study of Pain From Magnetic Resonance Imaging With Cochlear Implant Magnets In Situ.
    Pross SE; Ward BK; Sharon JD; Weinreich HM; Aygun N; Francis HW
    Otol Neurotol; 2018 Feb; 39(2):e80-e86. PubMed ID: 29210950
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Cochlear implant user perceptions of magnetic resonance imaging.
    Dewey RS; Kitterick PT
    Cochlear Implants Int; 2022 Jan; 23(1):11-20. PubMed ID: 34315344
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [MRI in patients with auditory implants equipped with implanted magnets-an update : Overview and procedural management].
    Nospes S; Brockmann MA; Läßig A
    Radiologe; 2019 Jan; 59(1):48-56. PubMed ID: 30350108
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Magnetic resonance imaging in patients with magnetic hearing implants: overview and procedural management].
    Nospes S; Mann W; Keilmann A
    Radiologe; 2013 Nov; 53(11):1026-32. PubMed ID: 24113904
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Magnetic resonance imaging compatibility testing of the Clarion 1.2 cochlear implant.
    Weber BP; Goldring JE; Santogrossi T; Koestler H; Tziviskos G; Battmer R; Lenarz Th
    Am J Otol; 1998 Sep; 19(5):584-90. PubMed ID: 9752965
    [TBL] [Abstract][Full Text] [Related]  

  • 34. MRI induced torque and demagnetization in retention magnets for a bone conduction implant.
    Jansson KJ; Håkansson B; Reinfeldt S; Taghavi H; Eeg-Olofsson M
    IEEE Trans Biomed Eng; 2014 Jun; 61(6):1887-93. PubMed ID: 24845299
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Dislocation of cochlear implant magnet during 1.5 Tesla magnetic resonance imaging despite head bandaging, and its repositioning using an endoscopic approach.
    Leong WJC; Yuen HW
    J Laryngol Otol; 2018 Oct; 132(10):943-945. PubMed ID: 30152297
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Magnetic resonance imaging compatibility and safety of the SOUNDTEC Direct System.
    Dyer RK; Nakmali D; Dormer KJ
    Laryngoscope; 2006 Aug; 116(8):1321-33. PubMed ID: 16885731
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Clinical application of magnetic resonance imaging in 30 cochlear implant patients.
    Baumgartner WD; Youssefzadeh S; Hamzavi J; Czerny C; Gstoettner W
    Otol Neurotol; 2001 Nov; 22(6):818-22. PubMed ID: 11698802
    [TBL] [Abstract][Full Text] [Related]  

  • 38. 3 Tesla MRI brain scanning under general anaesthesia in a paediatric 3 Tesla-compatible cochlear implant recipient, first reported case: Clinical considerations and implications for future practice.
    Zhen E; Kuthubutheen J; Misso D; Rodrigues S; Thompson A
    Int J Pediatr Otorhinolaryngol; 2020 Jun; 133():110015. PubMed ID: 32229365
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Cochlear implants and 1.5 T MRI scans: the effect of diametrically bipolar magnets and screw fixation on pain.
    Todt I; Rademacher G; Grupe G; Stratmann A; Ernst A; Mutze S; Mittmann P
    J Otolaryngol Head Neck Surg; 2018 Feb; 47(1):11. PubMed ID: 29402322
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Cochlear implant magnet displacement during magnetic resonance imaging.
    Deneuve S; Loundon N; Leboulanger N; Rouillon I; Garabedian EN
    Otol Neurotol; 2008 Sep; 29(6):789-190. PubMed ID: 18667941
    [TBL] [Abstract][Full Text] [Related]  