These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

267 related articles for article (PubMed ID: 30944001)

  • 1. Reliability of three-dimensional color flow Doppler and two-dimensional pulse wave Doppler transthoracic echocardiography for estimating cardiac output after cardiac surgery.
    Hao GW; Liu Y; Ma GG; Hou JY; Zhu DM; Liu L; Zhang Y; Liu H; Zhuang YM; Luo Z; Tu GW; Yang XM; Chen HY
    Cardiovasc Ultrasound; 2019 Apr; 17(1):5. PubMed ID: 30944001
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Inaccuracy of the FloTrac/Vigileo™ system in patients with low cardiac index.
    Maeda T; Yoshitani K; Inatomi Y; Ohnishi Y
    J Cardiothorac Vasc Anesth; 2014 Dec; 28(6):1521-6. PubMed ID: 25306519
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparing Methods for Cardiac Output: Intraoperatively Doppler-Derived Cardiac Output Measured With 3-Dimensional Echocardiography Is Not Interchangeable With Cardiac Output by Pulmonary Catheter Thermodilution.
    Graeser K; Zemtsovski M; Kofoed KF; Winther-Jensen M; Nilsson JC; Kjaergaard J; Møller-Sørensen H
    Anesth Analg; 2018 Aug; 127(2):399-407. PubMed ID: 29324489
    [TBL] [Abstract][Full Text] [Related]  

  • 4. FloTrac/Vigileo(TM) (third generation) and MostCare(®)/PRAM versus echocardiography for cardiac output estimation in vascular surgery.
    Romagnoli S; Ricci Z; Romano SM; Dimizio F; Bonicolini E; Quattrone D; De Gaudio R
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1114-21. PubMed ID: 24055563
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient.
    Mercado P; Maizel J; Beyls C; Titeca-Beauport D; Joris M; Kontar L; Riviere A; Bonef O; Soupison T; Tribouilloy C; de Cagny B; Slama M
    Crit Care; 2017 Jun; 21(1):136. PubMed ID: 28595621
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reliability of cardiac output measurements using LiDCOrapid™ and FloTrac/Vigileo™ across broad ranges of cardiac output values.
    Asamoto M; Orii R; Otsuji M; Bougaki M; Imai Y; Yamada Y
    J Clin Monit Comput; 2017 Aug; 31(4):709-716. PubMed ID: 27300325
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A minimally invasive monitoring system of cardiac output using aortic flow velocity and peripheral arterial pressure profile.
    Uemura K; Kawada T; Inagaki M; Sugimachi M
    Anesth Analg; 2013 May; 116(5):1006-1017. PubMed ID: 23492964
    [TBL] [Abstract][Full Text] [Related]  

  • 8. CARDIAC OUTPUT IN CRITICALLY ILL PATIENTS CAN BE ESTIMATED EASILY AND ACCURATELY USING THE MINUTE DISTANCE OBTAINED BY PULSED-WAVE DOPPLER.
    Villavicencio C; Daniel X; Cartanyá M; Leache J; Ferré C; Roure M; Bodí M; Vives M; Rodriguez A
    Shock; 2023 Oct; 60(4):553-559. PubMed ID: 37698504
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automated cardiac output measurement by spatiotemporal integration of color Doppler data. In vitro and clinical validation.
    Sun JP; Pu M; Fouad FM; Christian R; Stewart WJ; Thomas JD
    Circulation; 1997 Feb; 95(4):932-9. PubMed ID: 9054753
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy and precision of the ultrasound cardiac output monitor (USCOM 1A) in pregnancy: comparison with three-dimensional transthoracic echocardiography.
    McNamara H; Barclay P; Sharma V
    Br J Anaesth; 2014 Oct; 113(4):669-76. PubMed ID: 25005720
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automated quantification of mitral inflow and aortic outflow stroke volumes by three-dimensional real-time volume color-flow Doppler transthoracic echocardiography: comparison with pulsed-wave Doppler and cardiac magnetic resonance imaging.
    Thavendiranathan P; Liu S; Datta S; Walls M; Nitinunu A; Van Houten T; Tomson NA; Vidmar L; Georgescu B; Wang Y; Srinivasan S; De Michelis N; Raman SV; Ryan T; Vannan MA
    J Am Soc Echocardiogr; 2012 Jan; 25(1):56-65. PubMed ID: 22105057
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The diagnostic accuracy of estimated continuous cardiac output compared with transthoracic echocardiography.
    Fischer MO; Balaire X; Le Mauff de Kergal C; Boisselier C; Gérard JL; Hanouz JL; Fellahi JL
    Can J Anaesth; 2014 Jan; 61(1):19-26. PubMed ID: 24155127
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ability of esCCO to track changes in cardiac output.
    Biais M; Berthezène R; Petit L; Cottenceau V; Sztark F
    Br J Anaesth; 2015 Sep; 115(3):403-10. PubMed ID: 26209443
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.
    Missant C; Rex S; Wouters PF
    Eur J Anaesthesiol; 2008 Mar; 25(3):243-8. PubMed ID: 17996125
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ability of the third-generation FloTrac/Vigileo software to track changes in cardiac output in cardiac surgery patients: a polar plot approach.
    Desebbe O; Henaine R; Keller G; Koffel C; Garcia H; Rosamel P; Obadia JF; Bastien O; Lehot JJ; Haftek M; Critchley LA
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1122-7. PubMed ID: 24011911
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel operator-independent algorithm for cardiac output measurements based on three-dimensional transoesophageal colour Doppler echocardiography.
    Matthews F; Largiadèr T; Rhomberg P; van der Loo B; Schmid ER; Jenni R
    Eur J Echocardiogr; 2010 Jun; 11(5):432-7. PubMed ID: 20106879
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transoesophageal echocardiography accurately detects cardiac output variation: a prospective comparison with thermodilution in cardiac surgery.
    Parra V; Fita G; Rovira I; Matute P; Gomar C; Paré C
    Eur J Anaesthesiol; 2008 Feb; 25(2):135-43. PubMed ID: 17672920
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy and trending ability of the fourth-generation FloTrac/Vigileo System™ in patients undergoing abdominal aortic aneurysm surgery.
    Maeda T; Hattori K; Sumiyoshi M; Kanazawa H; Ohnishi Y
    J Anesth; 2018 Jun; 32(3):387-393. PubMed ID: 29616345
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of a new 3-dimensional color Doppler flow method to quantify flow across the mitral valve and in the left ventricular outflow tract: an in vitro study.
    Kimura S; Streiff C; Zhu M; Shimada E; Datta S; Ashraf M; Sahn DJ
    J Ultrasound Med; 2014 Feb; 33(2):265-71. PubMed ID: 24449729
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of Cardiac Output of Both 2-Dimensional and 3-Dimensional Transesophageal Echocardiography With Transpulmonary Thermodilution During Cardiac Surgery.
    Canty DJ; Kim M; Guha R; Pham T; Royse AG; Errey-Clarke S; Smith JA; Royse CF
    J Cardiothorac Vasc Anesth; 2020 Jan; 34(1):77-86. PubMed ID: 31375406
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.