BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

380 related articles for article (PubMed ID: 30950234)

  • 1. Evaluation of endoscopic reintervention for self-expandable metallic stent obstruction after stent-in-stent placement for malignant hilar biliary obstruction.
    Okuno M; Mukai T; Iwashita T; Ichikawa H; Iwasa Y; Mita N; Yoshida K; Iwata K; Tomita E; Shimizu M
    J Hepatobiliary Pancreat Sci; 2019 Jun; 26(6):211-218. PubMed ID: 30950234
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The evaluation of bilateral stenting using braided or laser-cut self-expandable metallic stent for malignant hilar biliary obstruction.
    Okuno M; Iwata K; Mukai T; Ohashi Y; Iwata S; Iwasa Y; Yoshida K; Maruta A; Tezuka R; Ichikawa H; Mita N; Uemura S; Iwashita T; Tomita E; Shimizu M
    Surg Endosc; 2023 Nov; 37(11):8489-8497. PubMed ID: 37759143
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction.
    Sugimoto M; Takagi T; Suzuki R; Konno N; Asama H; Watanabe K; Nakamura J; Kikuchi H; Waragai Y; Takasumi M; Sato Y; Hikichi T; Ohira H
    World J Gastroenterol; 2017 Sep; 23(34):6273-6280. PubMed ID: 28974893
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reintervention for stent occlusion after bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction.
    Inoue T; Naitoh I; Okumura F; Ozeki T; Anbe K; Iwasaki H; Nishie H; Mizushima T; Sano H; Nakazawa T; Yoneda M; Joh T
    Dig Endosc; 2016 Nov; 28(7):731-737. PubMed ID: 27088888
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluating optimal bilateral biliary stenting in endoscopic reintervention after initial plastic stent dysfunction for unresectable malignant hilar biliary obstruction: Retrospective cross-sectional study.
    Okuno M; Iwata K; Iwashita T; Mukai T; Shimojo K; Ohashi Y; Iwasa Y; Senju A; Iwata S; Tezuka R; Ichikawa H; Mita N; Uemura S; Yoshida K; Maruta A; Tomita E; Yasuda I; Shimizu M
    Dig Endosc; 2024 Mar; ():. PubMed ID: 38486465
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High single-session success rate of endoscopic bilateral stent-in-stent placement with modified large cell Niti-S stents for malignant hilar biliary obstruction.
    Kogure H; Isayama H; Nakai Y; Tsujino T; Matsubara S; Yashima Y; Ito Y; Hamada T; Takahara N; Miyabayashi K; Mizuno S; Mohri D; Kawakubo K; Sasaki T; Yamamoto N; Hirano K; Sasahira N; Tada M; Koike K
    Dig Endosc; 2014 Jan; 26(1):93-9. PubMed ID: 23517109
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 8-mm versus 10-mm diameter self-expandable metallic stent in bilateral endoscopic stent-in-stent deployment for malignant hilar biliary obstruction.
    Naitoh I; Nakazawa T; Ban T; Okumura F; Hirano A; Takada H; Togawa S; Hayashi K; Miyabe K; Shimizu S; Kondo H; Nishi Y; Yoshida M; Yamashita H; Umemura S; Hori Y; Kato A; Sano H; Joh T
    J Hepatobiliary Pancreat Sci; 2015 May; 22(5):396-401. PubMed ID: 25611012
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Endoscopic biliary stent insertion through specialized duodenal stent for combined malignant biliary and duodenal obstruction facilitated by stent or PTBD guidance.
    Lee JJ; Hyun JJ; Choe JW; Lee DW; Kim SY; Jung SW; Jung YK; Koo JS; Yim HJ; Lee SW
    Scand J Gastroenterol; 2017 Nov; 52(11):1258-1262. PubMed ID: 28685637
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Placement of a Newly Designed Y-Configured Bilateral Self-Expanding Metallic Stent for Hilar Biliary Obstruction: A Pilot Study.
    Jiao D; Huang K; Zhu M; Wu G; Ren J; Wang Y; Han X
    Dig Dis Sci; 2017 Jan; 62(1):253-263. PubMed ID: 27586033
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Utility of bilateral intraductal plastic stent for malignant hilar biliary obstruction compared with bilateral self-expandable metal stent: a propensity score-matched cohort analysis.
    Okuno M; Iwata K; Iwashita T; Mukai T; Shimojo K; Ohashi Y; Iwasa Y; Senju A; Iwata S; Tezuka R; Ichikawa H; Mita N; Uemura S; Yoshida K; Maruta A; Tomita E; Yasuda I; Shimizu M
    Gastrointest Endosc; 2023 Nov; 98(5):776-786. PubMed ID: 37392955
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Combined side-by-side and stent-in-stent method for triple metal stenting in patients with malignant hilar biliary obstruction.
    Inoue T; Ibusuki M; Kitano R; Kobayashi Y; Ohashi T; Nakade Y; Sumida Y; Ito K; Nakao H; Yoneda M
    Dig Endosc; 2019 Nov; 31(6):698-705. PubMed ID: 31120163
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Revision of bilateral self-expandable metallic stents placed using the stent-in-stent technique for malignant hilar biliary obstruction.
    Son JH; Lee HS; Lee SH; Bang S; Kang J; Paik WH; Ryu JK; Kim YT
    Hepatobiliary Pancreat Dis Int; 2018 Oct; 17(5):437-442. PubMed ID: 30082195
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Expandable metal stents for endoscopic bilateral stent-within-stent placement for malignant hilar biliary obstruction.
    Chahal P; Baron TH
    Gastrointest Endosc; 2010 Jan; 71(1):195-9. PubMed ID: 19945101
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Usefulness of a newly designed plastic stent for endoscopic re-intervention in patients with malignant hilar biliary obstruction.
    Tomoda T; Kato H; Kawamoto H; Muro S; Akimoto Y; Uchida D; Matsumoto K; Horiguchi S; Tsutsumi K; Okada H
    Endoscopy; 2017 Nov; 49(11):1087-1091. PubMed ID: 28753695
    [No Abstract]   [Full Text] [Related]  

  • 15. Risk factors for technical failure of endoscopic double self-expandable metallic stent placement by partial stent-in-stent method.
    Kawakubo K; Kawakami H; Toyokawa Y; Otani K; Kuwatani M; Abe Y; Kawahata S; Kubo K; Kubota Y; Sakamoto N
    J Hepatobiliary Pancreat Sci; 2015 Jan; 22(1):79-85. PubMed ID: 25308061
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Self-expandable metal stents versus plastic stents for malignant biliary obstruction: a meta-analysis.
    Sawas T; Al Halabi S; Parsi MA; Vargo JJ
    Gastrointest Endosc; 2015 Aug; 82(2):256-267.e7. PubMed ID: 25982849
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Covered Wallstents for palliation of malignant biliary obstruction: primary stent placement versus reintervention.
    Ornellas LC; Stefanidis G; Chuttani R; Gelrud A; Kelleher TB; Pleskow DK
    Gastrointest Endosc; 2009 Oct; 70(4):676-83. PubMed ID: 19560137
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical Outcomes of Bilateral Stent-in-Stent Placement Using Self-Expandable Metallic Stent for High-Grade Malignant Hilar Biliary Obstruction.
    Heo JY; Lee HS; Son JH; Lee SH; Bang S
    Yonsei Med J; 2018 Sep; 59(7):827-833. PubMed ID: 30091315
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Risk factors for recurrent biliary obstruction following placement of self-expandable metallic stents in patients with malignant perihilar biliary stricture.
    Miura S; Kanno A; Masamune A; Hamada S; Hongou S; Yoshida N; Nakano E; Takikawa T; Kume K; Kikuta K; Hirota M; Yoshida H; Katayose Y; Unno M; Shimosegawa T
    Endoscopy; 2016 Jun; 48(6):536-45. PubMed ID: 26987646
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Single-step simultaneous side-by-side placement of a self-expandable metallic stent with a 6-Fr delivery system for unresectable malignant hilar biliary obstruction: a feasibility study.
    Kawakubo K; Kawakami H; Kuwatani M; Kudo T; Abe Y; Kawahata S; Kubo K; Kubota Y; Sakamoto N
    J Hepatobiliary Pancreat Sci; 2015 Feb; 22(2):151-5. PubMed ID: 25345586
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.