These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Mechanical thrombectomy with a novel device: initial clinical experience with the ANA thrombectomy device. Tomasello A; Hernandez D; Piñana C; Requena M; Liebeskind DS; Nogueira RG; Jovin T; Andersson T; Cognard C; Siddiqui A; Ribo M J Neuroradiol; 2022 Jun; 49(4):324-328. PubMed ID: 33340641 [TBL] [Abstract][Full Text] [Related]
4. Mechanical Thrombectomy Using the new Solitaire™ Platinum Stent-retriever : Reperfusion Results, Complication Rates and Early Neurological Outcome. Pfaff J; Rohde S; Engelhorn T; Doerfler A; Bendszus M; Möhlenbruch MA Clin Neuroradiol; 2019 Jun; 29(2):311-319. PubMed ID: 29322232 [TBL] [Abstract][Full Text] [Related]
5. Mechanical Thrombectomy with the Novel NeVa M1 Stent Retriever: Do the Drop Zones Represent a Risk or a Benefit? Borggrefe J; Goertz L; Abdullayev N; Hokamp NG; Kowoll CM; Onur Ö; Kabbasch C; Schlamann M World Neurosurg; 2021 Apr; 148():e121-e129. PubMed ID: 33359523 [TBL] [Abstract][Full Text] [Related]
6. Experimental evaluation of the NeVa™ thrombectomy device a novel stent retriever conceived to improve efficacy of organized clot removal. Machi P; Ulm AJ; Bernava G; Brina O; Lovblad KO; Jourdan F J Neuroradiol; 2019 May; 46(3):163-167. PubMed ID: 29625154 [TBL] [Abstract][Full Text] [Related]
7. First-Pass Reperfusion by Mechanical Thrombectomy in Acute M1 Occlusion: The Size of Retriever Matters. Serna Candel C; Aguilar Pérez M; Bäzner H; Henkes H; Hellstern V Front Neurol; 2021; 12():679402. PubMed ID: 34267722 [No Abstract] [Full Text] [Related]
8. The pREset Stent Retriever for Endovascular Treatment of Stroke Caused by MCA Occlusion: Safety and Clinical Outcome. Schwaiger BJ; Kober F; Gersing AS; Kleine JF; Wunderlich S; Zimmer C; Poppert H; Prothmann S Clin Neuroradiol; 2016 Mar; 26(1):47-55. PubMed ID: 25112831 [TBL] [Abstract][Full Text] [Related]
9. Immediate and 90-Day Clinical Outcome of Patients with Acute Stroke Treated with the NeVa-Vesalio Mechanical Thrombectomy Device: A Retrospective Case Series. Melki GJ; Demeestere J; Laenen A; Bonne L; Claus E; Lambert J; Buyck PJ; Peluso J; Demaerel P; Lemmens R; Maleux G World Neurosurg; 2023 Nov; 179():e212-e221. PubMed ID: 37611801 [TBL] [Abstract][Full Text] [Related]
10. First pass results of mechanical thrombectomy with two-drop zone NeVa Bajrami A; Ertugrul O; Senadim S; Erdem E; Baltacioglu F; Geyik S Interv Neuroradiol; 2024 Aug; 30(4):458-462. PubMed ID: 36314456 [TBL] [Abstract][Full Text] [Related]
11. First-line lesional aspiration in acute stroke thrombectomy using a novel intermediate catheter: Initial experiences with the SOFIA. Kabbasch C; Möhlenbruch M; Stampfl S; Mpotsaris A; Behme D; Liebig T Interv Neuroradiol; 2016 Jun; 22(3):333-9. PubMed ID: 26908589 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of effectiveness and safety of the multizone NeVa Masthoff M; Krähling H; Akkurt BH; Elsharkawy M; Köhler M; Ergawy M; Thomas C; Schwindt W; Minnerup J; Stracke P Neuroradiology; 2023 Dec; 65(12):1777-1785. PubMed ID: 37878032 [TBL] [Abstract][Full Text] [Related]
13. Two-year single-center experience with the 'Baby Trevo' stent retriever for mechanical thrombectomy in acute ischemic stroke. Kühn AL; Wakhloo AK; Lozano JD; Massari F; De Macedo Rodrigues K; Marosfoi MG; Perras M; Brooks C; Howk M; Rex DE; Gounis MJ; Puri AS J Neurointerv Surg; 2017 Jun; 9(6):541-546. PubMed ID: 27286991 [TBL] [Abstract][Full Text] [Related]
15. A direct aspiration first-pass technique vs stentriever thrombectomy in emergent large vessel intracranial occlusions. Stapleton CJ; Leslie-Mazwi TM; Torok CM; Hakimelahi R; Hirsch JA; Yoo AJ; Rabinov JD; Patel AB J Neurosurg; 2018 Feb; 128(2):567-574. PubMed ID: 28409731 [TBL] [Abstract][Full Text] [Related]
16. First-In-Man Procedural Experience with the Novel EmboTrap® Revascularization Device for the Treatment of Ischemic Stroke-A European Multicenter Series. Kabbasch C; Mpotsaris A; Liebig T; Söderman M; Holtmannspötter M; Cronqvist M; Thornton J; Mendes Pereira V; Andersson T Clin Neuroradiol; 2016 Jun; 26(2):221-8. PubMed ID: 25366714 [TBL] [Abstract][Full Text] [Related]
17. Acute basilar artery occlusion: outcome of mechanical thrombectomy with Solitaire stent within 8 hours of stroke onset. Baek JM; Yoon W; Kim SK; Jung MY; Park MS; Kim JT; Kang HK AJNR Am J Neuroradiol; 2014 May; 35(5):989-93. PubMed ID: 24335542 [TBL] [Abstract][Full Text] [Related]
18. Acute combined revascularization in acute ischemic stroke with intracranial arterial occlusion: self-expanding solitaire stent during intravenous thrombolysis. Šaňák D; Köcher M; Veverka T; Černá M; Král M; Buřval S; Školoudík D; Prášil V; Zapletalová J; Herzig R; Kaňovský P J Vasc Interv Radiol; 2013 Sep; 24(9):1273-9. PubMed ID: 23973019 [TBL] [Abstract][Full Text] [Related]
19. Endovascular treatment of acute intracerebral artery occlusions with the solitaire stent: single-centre experience with 108 recanalization procedures. Dorn F; Stehle S; Lockau H; Zimmer C; Liebig T Cerebrovasc Dis; 2012; 34(1):70-7. PubMed ID: 22759754 [TBL] [Abstract][Full Text] [Related]
20. Neurothrombectomy for the treatment of acute ischemic stroke: results from the TREVO study. Jansen O; Macho JM; Killer-Oberpfalzer M; Liebeskind D; Wahlgren N; Cerebrovasc Dis; 2013; 36(3):218-25. PubMed ID: 24135533 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]