These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

250 related articles for article (PubMed ID: 30958484)

  • 21. Automation of macromolecular crystallography beamlines.
    Arzt S; Beteva A; Cipriani F; Delageniere S; Felisaz F; Förstner G; Gordon E; Launer L; Lavault B; Leonard G; Mairs T; McCarthy A; McCarthy J; McSweeney S; Meyer J; Mitchell E; Monaco S; Nurizzo D; Ravelli R; Rey V; Shepard W; Spruce D; Svensson O; Theveneau P
    Prog Biophys Mol Biol; 2005 Oct; 89(2):124-52. PubMed ID: 15910915
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Collecting data in the home laboratory: evolution of X-ray sources, detectors and working practices.
    Skarzynski T
    Acta Crystallogr D Biol Crystallogr; 2013 Jul; 69(Pt 7):1283-8. PubMed ID: 23793154
    [TBL] [Abstract][Full Text] [Related]  

  • 23. BL-11C Micro-MX: a high-flux microfocus macromolecular-crystallography beamline for micrometre-sized protein crystals at Pohang Light Source II.
    Gu DH; Eo C; Hwangbo SA; Ha SC; Kim JH; Kim H; Lee CS; Seo ID; Yun YD; Lee W; Choi H; Kim J; Lim J; Rah S; Kim JS; Lee JO; Kim YG; Park SY
    J Synchrotron Radiat; 2021 Jul; 28(Pt 4):1210-1215. PubMed ID: 34212886
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Squeezing the most from every crystal: the fine details of data collection.
    Krojer T; Pike AC; von Delft F
    Acta Crystallogr D Biol Crystallogr; 2013 Jul; 69(Pt 7):1303-13. PubMed ID: 23793157
    [TBL] [Abstract][Full Text] [Related]  

  • 25. MxDC and MxLIVE: software for data acquisition, information management and remote access to macromolecular crystallography beamlines.
    Fodje M; Janzen K; Berg R; Black G; Labiuk S; Gorin J; Grochulski P
    J Synchrotron Radiat; 2012 Mar; 19(Pt 2):274-80. PubMed ID: 22338690
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Advanced beamline automation for biological crystallography experiments.
    Cork C; O'Neill J; Taylor J; Earnest T
    Acta Crystallogr D Biol Crystallogr; 2006 Aug; 62(Pt 8):852-8. PubMed ID: 16855300
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Facilities for small-molecule crystallography at synchrotron sources.
    Barnett SA; Nowell H; Warren MR; Wilcox A; Allan DR
    Protein Pept Lett; 2016; 23(3):211-6. PubMed ID: 26767430
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Automation of the EMBL Hamburg protein crystallography beamline BW7B.
    Pohl E; Ristau U; Gehrmann T; Jahn D; Robrahn B; Malthan D; Dobler H; Hermes C
    J Synchrotron Radiat; 2004 Sep; 11(Pt 5):372-7. PubMed ID: 15310952
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A decade of user operation on the macromolecular crystallography MAD beamline ID14-4 at the ESRF.
    McCarthy AA; Brockhauser S; Nurizzo D; Theveneau P; Mairs T; Spruce D; Guijarro M; Lesourd M; Ravelli RB; McSweeney S
    J Synchrotron Radiat; 2009 Nov; 16(Pt 6):803-12. PubMed ID: 19844017
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Robust structural analysis of native biological macromolecules from multi-crystal anomalous diffraction data.
    Liu Q; Liu Q; Hendrickson WA
    Acta Crystallogr D Biol Crystallogr; 2013 Jul; 69(Pt 7):1314-32. PubMed ID: 23793158
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Characterization of wax as a potential diffraction intensity standard for macromolecular crystallography beamlines.
    Brandao-Neto J; Thompson SP; Lennie AR; Ferreira FF; Tang CC
    J Synchrotron Radiat; 2010 Jan; 17(1):53-60. PubMed ID: 20029111
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Facilitating best practices in collecting anomalous scattering data for de novo structure solution at the ESRF Structural Biology Beamlines.
    de Sanctis D; Oscarsson M; Popov A; Svensson O; Leonard G
    Acta Crystallogr D Struct Biol; 2016 Mar; 72(Pt 3):413-20. PubMed ID: 26960128
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Macromolecular crystallography beamline X25 at the NSLS.
    Héroux A; Allaire M; Buono R; Cowan ML; Dvorak J; Flaks L; Lamarra S; Myers SF; Orville AM; Robinson HH; Roessler CG; Schneider DK; Shea-McCarthy G; Skinner JM; Skinner M; Soares AS; Sweet RM; Berman LE
    J Synchrotron Radiat; 2014 May; 21(Pt 3):627-32. PubMed ID: 24763654
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Robotic sample changers for macromolecular X-ray crystallography and biological small-angle X-ray scattering at the National Synchrotron Light Source II.
    Lazo EO; Antonelli S; Aishima J; Bernstein HJ; Bhogadi D; Fuchs MR; Guichard N; McSweeney S; Myers S; Qian K; Schneider D; Shea-McCarthy G; Skinner J; Sweet R; Yang L; Jakoncic J
    J Synchrotron Radiat; 2021 Sep; 28(Pt 5):1649-1661. PubMed ID: 34475312
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Acoustic methods for high-throughput protein crystal mounting at next-generation macromolecular crystallographic beamlines.
    Roessler CG; Kuczewski A; Stearns R; Ellson R; Olechno J; Orville AM; Allaire M; Soares AS; Héroux A
    J Synchrotron Radiat; 2013 Sep; 20(Pt 5):805-8. PubMed ID: 23955046
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Crystallographic data collection using a 0.22% bandwidth multilayer.
    Englich U; Kazimirov A; Shen Q; Bilderback DH; Gruner SM; Hao Q
    J Synchrotron Radiat; 2005 May; 12(Pt 3):345-8. PubMed ID: 15840920
    [TBL] [Abstract][Full Text] [Related]  

  • 37. ID23-2: an automated and high-performance microfocus beamline for macromolecular crystallography at the ESRF.
    Nanao M; Basu S; Zander U; Giraud T; Surr J; Guijarro M; Lentini M; Felisaz F; Sinoir J; Morawe C; Vivo A; Beteva A; Oscarsson M; Caserotto H; Dobias F; Flot D; Nurizzo D; Gigmes J; Foos N; Siebrecht R; Roth T; Theveneau P; Svensson O; Papp G; Lavault B; Cipriani F; Barrett R; Clavel C; Leonard G
    J Synchrotron Radiat; 2022 Mar; 29(Pt 2):581-590. PubMed ID: 35254323
    [TBL] [Abstract][Full Text] [Related]  

  • 38. High-throughput in situ experimental phasing.
    Lawrence JM; Orlans J; Evans G; Orville AM; Foadi J; Aller P
    Acta Crystallogr D Struct Biol; 2020 Aug; 76(Pt 8):790-801. PubMed ID: 32744261
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Designing a synchrotron micro-focusing beamline for macromolecular crystallography.
    Grochulski P; Cygler M; Yates B
    Postepy Biochem; 2016; 62(3):395-400. PubMed ID: 28132495
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A new paradigm for macromolecular crystallography beamlines derived from high-pressure methodology and results.
    Fourme R; Girard E; Dhaussy AC; Medjoubi K; Prangé T; Ascone I; Mezouar M; Kahn R
    J Synchrotron Radiat; 2011 Jan; 18(1):31-6. PubMed ID: 21169687
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.