These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

220 related articles for article (PubMed ID: 30959545)

  • 1. Efficacy of Portable Accelerometer-Based Navigation Devices versus Conventional Guides in Total Knee Arthroplasty: A Meta-analysis.
    Sun H; Li S; Wang K; Wu G; Zhou J; Sun X
    J Knee Surg; 2020 Jul; 33(7):691-703. PubMed ID: 30959545
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An accelerometer-based portable navigation system improved prosthetic alignment after total knee arthroplasty in 3D measurements.
    Ueyama H; Minoda Y; Sugama R; Ohta Y; Yamamura K; Nakamura S; Takemura S; Nakamura H
    Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1580-1586. PubMed ID: 30066018
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative Study for Alignment of Extramedullary Guides versus Portable, Accelerometer-Based Navigation in Total Knee Arthroplasty.
    Matsumoto K; Ogawa H; Fukuta M; Mori N; Akiyama H
    J Knee Surg; 2018 Jan; 31(1):92-98. PubMed ID: 28460410
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Technical Considerations and Accuracy Improvement of Accelerometer-Based Portable Computer Navigation for Performing Distal Femoral Resection in Total Knee Arthroplasty.
    Fujimoto E; Sasashige Y; Nakata K; Yokota G; Omoto T; Ochi M
    J Arthroplasty; 2017 Jan; 32(1):53-60. PubMed ID: 27365295
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment.
    Moon YW; Ha CW; Do KH; Kim CY; Han JH; Na SE; Lee CH; Kim JG; Park YS
    Comput Aided Surg; 2012; 17(2):86-95. PubMed ID: 22348661
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Total Knee Arthroplasty in Patients With Extra-Articular Deformity: Restoration of Mechanical Alignment Using Accelerometer-Based Navigation System.
    Matassi F; Cozzi Lepri A; Innocenti M; Zanna L; Civinini R; Innocenti M
    J Arthroplasty; 2019 Apr; 34(4):676-681. PubMed ID: 30685259
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The accelerometer-based navigation system demonstrated superior radiological outcomes in restoring mechanical alignment and component sagittal positioning in total knee arthroplasty.
    Gao J; Hou Y; Li R; Ke Y; Li Z; Lin J
    BMC Musculoskelet Disord; 2021 Apr; 22(1):351. PubMed ID: 33849489
    [TBL] [Abstract][Full Text] [Related]  

  • 8. No definite advantage of a portable accelerometer-based navigation system over conventional technique in total knee arthroplasty: A systematic review and meta-analysis.
    Shigemura T; Murata Y; Yamamoto Y; Mizuki N; Toki Y; Wada Y
    Orthop Traumatol Surg Res; 2019 Jun; 105(4):619-626. PubMed ID: 31040097
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Comparison of alignment and operative time between portable accelerometer-based navigation device and computer assisted surgery in total knee arthroplasty].
    Wang XG; Geng X; Li Y; Wu TC; Li ZJ; Tian H
    Beijing Da Xue Xue Bao Yi Xue Ban; 2021 Aug; 53(4):728-733. PubMed ID: 34393236
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of iASSIST Navigation System with Conventional Techniques in Total Knee Arthroplasty: A Systematic Review and Meta-Analysis of Radiographic and Clinical Outcomes.
    Li JT; Gao X; Li X
    Orthop Surg; 2019 Dec; 11(6):985-993. PubMed ID: 31755245
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radiographic results of an accelerometer-based, handheld surgical navigation system for the tibial resection in total knee arthroplasty.
    Nam D; Cross M; Deshmane P; Jerabek S; Kang M; Mayman DJ
    Orthopedics; 2011 Oct; 34(10):e615-21. PubMed ID: 21956055
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An accelerometer-based navigation did not improve the femoral component positioning compared to a modified conventional technique of pre-operatively planned placement of intramedullary rod in total knee arthroplasty.
    Tsukeoka T; Tsuneizumi Y; Yoshino K
    Arch Orthop Trauma Surg; 2019 Apr; 139(4):561-567. PubMed ID: 30756166
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The efficacy and safety of patient-specific instrumentation versus conventional instrumentation for unicompartmental knee arthroplasty: Evidence from a meta-analysis.
    Wang H; Zhang L; Teng X
    Medicine (Baltimore); 2024 Jan; 103(3):e36484. PubMed ID: 38241557
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?
    Cheng T; Zhao S; Peng X; Zhang X
    Knee Surg Sports Traumatol Arthrosc; 2012 Jul; 20(7):1307-22. PubMed ID: 21732057
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Limb and component alignment after total knee arthroplasty comparing 28 consecutive iAssist and 28 conventional TKAs: A prospective study.
    Ehrendorfer S; Erdmenger U; Bocanegra LM; Boyd M; Canal J; Canal J; Hoch A; Windhager R; Niehaus R
    Knee; 2020 Dec; 27(6):1881-1888. PubMed ID: 33212313
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of the radiological results between fluoroscopy-assisted and navigation-guided total knee arthroplasty.
    Jung YB; Lee HJ; Jung HJ; Song KS; Lee JS; Yang JJ
    Knee Surg Sports Traumatol Arthrosc; 2009 Mar; 17(3):286-92. PubMed ID: 19104773
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Association of sagittal alignment of tibial and femoral components with clinical outcome in total knee arthroplasty: A prospective cohort study.
    Guruprasad HB; Singh M; Naik AK; Jain VK
    J Orthop; 2023 Oct; 44():72-76. PubMed ID: 37720915
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Are There Differences in Accuracy or Outcomes Scores Among Navigated, Robotic, Patient-specific Instruments or Standard Cutting Guides in TKA? A Network Meta-analysis.
    Bouché PA; Corsia S; Dechartres A; Resche-Rigon M; Nizard R
    Clin Orthop Relat Res; 2020 Sep; 478(9):2105-2116. PubMed ID: 32530896
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Computer-assisted stereotaxic navigation improves the accuracy of mechanical alignment and component positioning in total knee arthroplasty.
    Liow MH; Goh GS; Pang HN; Tay DK; Lo NN; Yeo SJ
    Arch Orthop Trauma Surg; 2016 Aug; 136(8):1173-80. PubMed ID: 27349233
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved implant alignment accuracy with an accelerometer-based portable navigation system in medial unicompartmental knee arthroplasty.
    Suda Y; Takayama K; Ishida K; Hayashi S; Hashimoto S; Niikura T; Matsushita T; Kuroda R; Matsumoto T
    Knee Surg Sports Traumatol Arthrosc; 2020 Sep; 28(9):2917-2923. PubMed ID: 31451844
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.