These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 30959736)

  • 1. Absolute Single Cavity Length Interrogation of Fiber-Optic Compound Fabry⁻Perot Pressure Sensors Through a White Light Non-Scanning Correlation Method.
    Guo Z; Lv W; Wang W; Chen Q; Zhang X; Chen H; Ma Z
    Sensors (Basel); 2019 Apr; 19(7):. PubMed ID: 30959736
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Two-Parameter Elliptical Fitting Method for Short-Cavity Fiber Fabry⁻Perot Sensor Interrogation.
    Zhang X; Wang W; Chen H; Tang Y; Ma Z; Wang K
    Sensors (Basel); 2018 Dec; 19(1):. PubMed ID: 30583493
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Zero-Cross Detection Algorithm for Cavity-Length Interrogation of Fiber-Optic Fabry-Perot Sensors.
    Ma Z; Song Z; Huang X; Guo T; Yuan W; Chen H; Zhang T; Wang W
    Sensors (Basel); 2019 Sep; 19(18):. PubMed ID: 31500318
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-speed, large dynamic range spectral domain interrogation of fiber-optic Fabry-Perot interferometric sensors.
    Wong KP; Kim HT; Rajasekaran K; Yazdkhasti A; Sai Sudhakar B; Wang A; Lee SE; Kiger K; Duncan JH; Yu M
    Appl Opt; 2022 Jun; 61(16):4670-4677. PubMed ID: 36255944
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Squared peak-to-peak algorithm for the spectral interrogation of short-cavity fiber-optic Fabry-Perot sensors.
    Chen H; Zhang Y; Li Y; Jing X; Yuan S; Zhang X; Wang W; Liu R; Guo Q
    Appl Opt; 2020 Feb; 59(4):1198-1205. PubMed ID: 32225261
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Low-Cost, High-Performance Fiber Optic Fabry⁻Perot Sensor for Ultrasonic Wave Detection.
    Li H; Li D; Xiong C; Si W; Fu C; Yuan P; Yu Y
    Sensors (Basel); 2019 Jan; 19(2):. PubMed ID: 30669494
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High-resolution interrogation technique for fiber optic extrinsic Fabry-Perot interferometric sensors by the peak-to-peak method.
    Jiang Y
    Appl Opt; 2008 Mar; 47(7):925-32. PubMed ID: 18311264
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High-Precision Cavity Length Demodulation Method for Fiber-Optic Fabry-Perot Sensors Based on Dual Superluminescent Diodes.
    Zhang W; Yu J; Zhang X; Chen H; Zhang J; Wang W
    Sensors (Basel); 2022 Aug; 22(15):. PubMed ID: 35957455
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Diaphragm-Free Fiber-Optic Fabry-Perot Interferometric Gas Pressure Sensor for High Temperature Application.
    Liang H; Jia P; Liu J; Fang G; Li Z; Hong Y; Liang T; Xiong J
    Sensors (Basel); 2018 Mar; 18(4):. PubMed ID: 29597325
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tuning operating point of extrinsic Fabry-Perot interferometric fiber-optic sensors using microstructured fiber and gas pressure.
    Tian J; Zhang Q; Fink T; Li H; Peng W; Han M
    Opt Lett; 2012 Nov; 37(22):4672-4. PubMed ID: 23164875
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hybrid Fiber Optic Sensor, Based on the Fabry⁻Perot Interference, Assisted with Fluorescent Material for the Simultaneous Measurement of Temperature and Pressure.
    Jiang X; Lin C; Huang Y; Luo K; Zhang J; Jiang Q; Zhang C
    Sensors (Basel); 2019 Mar; 19(5):. PubMed ID: 30836683
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Signal-processing algorithm for white-light optical fiber extrinsic Fabry-Perot interferometric sensors.
    Han M; Zhang Y; Shen F; Pickrell GR; Wang A
    Opt Lett; 2004 Aug; 29(15):1736-8. PubMed ID: 15352354
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Five-step phase-shifting white-light interferometry for the measurement of fiber optic extrinsic Fabry-Perot interferometers.
    Gao H; Jiang Y; Zhang L; Jiang L
    Appl Opt; 2018 Feb; 57(5):1168-1173. PubMed ID: 29469861
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Frequency-estimation-based signal-processing algorithm for white-light optical fiber Fabry-Perot interferometers.
    Shen F; Wang A
    Appl Opt; 2005 Sep; 44(25):5206-14. PubMed ID: 16149344
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fabry⁻Perot Cavity Sensing Probe with High Thermal Stability for an Acoustic Sensor by Structure Compensation.
    Cheng J; Zhou Y; Zou X
    Sensors (Basel); 2018 Oct; 18(10):. PubMed ID: 30309042
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simultaneous measurement of acoustic pressure and temperature using a Fabry-Perot interferometric fiber-optic cantilever sensor.
    Chen K; Yang B; Deng H; Guo M; Zhang B; Yang Y; Liu S; Zhao Y; Peng W; Yu Q
    Opt Express; 2020 May; 28(10):15050-15061. PubMed ID: 32403538
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Four-wavelength laser interferometry for the demodulation of dual-cavity fiber-optic extrinsic Fabry-Perot interferometric sensors.
    Han Y; Jiang Y; Jia J; Zhang Y
    Opt Express; 2024 Apr; 32(8):14200-14210. PubMed ID: 38859372
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Extensible multi-wavelength interrogation method for arbitrary cavities in low-fineness multi-cavity Fabry-Pérot interferometric sensors.
    Zhao A; Ren Q; Su C; Tu J; Huang Y; An G; Liu J; Jia P; Xiong J
    Opt Express; 2024 Feb; 32(4):6141-6153. PubMed ID: 38439324
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Asymmetric Fabry-Pérot fiber-optic pressure sensor for liquid-level measurement.
    Lu T; Li Z; Xia D; He K; Zhang G
    Rev Sci Instrum; 2009 Mar; 80(3):033104. PubMed ID: 19334904
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of fiber bending on wavelength demodulation of fiber-optic Fabry-Perot interferometric sensors.
    Liu G; Sheng Q; Hou W; Han M
    Opt Express; 2016 Nov; 24(23):26732-26744. PubMed ID: 27857404
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.