These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
27. Decision-making in the choice of heart valve for replacement in patients aged 60-70 years: twenty-year follow up of the St. Jude Medical aortic valve prosthesis. Emery RW; Arom KV; Kshettry VR; Kroshus TJ; Von R; Kersten TE; Lillehei TJ; Nicoloff DM; Erickson CA J Heart Valve Dis; 2002 Jan; 11 Suppl 1():S37-44. PubMed ID: 11843519 [TBL] [Abstract][Full Text] [Related]
28. Early and late risk of aortic valve replacement. A 12 year concomitant comparison of the porcine bioprosthetic and tilting disc prosthetic aortic valves. Cohn LH; Allred EN; DiSesa VJ; Sawtelle K; Shemin RJ; Collins JJ J Thorac Cardiovasc Surg; 1984 Nov; 88(5 Pt 1):695-705. PubMed ID: 6492838 [TBL] [Abstract][Full Text] [Related]
32. [Bj"ork-Shiley heart vales at the Bern University Hospital. Long-term follow-up of 12 to 23 years after mitral and aortic valve replacement in 503 patients]. Stuber T; Kaufmann U; Kipfer B; Meier B Praxis (Bern 1994); 1999 Feb; 88(9):355-63. PubMed ID: 10191683 [TBL] [Abstract][Full Text] [Related]
33. Late results of heart valve replacement with the Hancock II bioprosthesis. David TE; Ivanov J; Armstrong S; Feindel CM; Cohen G J Thorac Cardiovasc Surg; 2001 Feb; 121(2):268-77. PubMed ID: 11174732 [TBL] [Abstract][Full Text] [Related]
34. [Long-term results of heterografts in the mitral position]. Ben Ismail M; Kafsi N; Ayari M Arch Mal Coeur Vaiss; 1984 Feb; 77(2):180-8. PubMed ID: 6424602 [TBL] [Abstract][Full Text] [Related]
36. Clinical and hemodynamic results of cardiac valve replacement with the Monostrut Björk-Shiley prosthesis. Aris A; Padró JM; Cámara ML; Crexells C; Augé JM; Caralps JM J Thorac Cardiovasc Surg; 1988 Mar; 95(3):423-31. PubMed ID: 3343851 [TBL] [Abstract][Full Text] [Related]
37. Heart valve replacement with the Ionescu-Shiley pericardial xenograft. Ionescu MI; Tandon AP; Mary DA; Abid A J Thorac Cardiovasc Surg; 1977 Jan; 73(1):31-42. PubMed ID: 831009 [TBL] [Abstract][Full Text] [Related]
38. A 5 1/2 year experience with the St. Jude Medical cardiac valve prosthesis. Early and late results of 737 valve replacements in 671 patients. Baudet EM; Oca CC; Roques XF; Laborde MN; Hafez AS; Collot MA; Ghidoni IM J Thorac Cardiovasc Surg; 1985 Jul; 90(1):137-44. PubMed ID: 3874324 [TBL] [Abstract][Full Text] [Related]
39. Carpentier-Edwards supra-annular bioprosthesis in the aortic position. Has altered design affected performance? Wilson ES; Jamieson MP J Heart Valve Dis; 1996 Jan; 5(1):40-4. PubMed ID: 8834724 [TBL] [Abstract][Full Text] [Related]
40. [Long-term results of isolated aortic valve replacement using a Bjork-Shiley prosthesis. A clinical study of a series of 365 patients with a postoperative follow-up of 8 to 16 years]. Logeais Y; Rioux C; Leguerrier A; Delambre JF; Langanay T; Staerman F; Chareton B; Goldmine M Ann Chir; 1989; 43(8):609-15. PubMed ID: 2589795 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]