BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

280 related articles for article (PubMed ID: 30967275)

  • 1. In vitro mechanical behavior and in vivo healing response of a novel thin-strut ultrahigh molecular weight poly-l-lactic acid sirolimus-eluting bioresorbable coronary scaffold in normal swine.
    Cheng Y; Gasior P; Ramzipoor K; Lee C; McGregor JC; Conditt GB; McAndrew T; Kaluza GL; Granada JF
    Int J Cardiol; 2019 Jul; 286():21-28. PubMed ID: 30967275
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative Biomechanical Behavior and Healing Profile of a Novel Thinned Wall Ultrahigh Molecular Weight Amorphous Poly-l-Lactic Acid Sirolimus-Eluting Bioresorbable Coronary Scaffold.
    Cheng Y; Gasior P; Xia JG; Ramzipoor K; Lee C; Estrada EA; Dokko D; McGregor JC; Conditt GB; McAndrew T; Kaluza GL; Granada JF
    Circ Cardiovasc Interv; 2017 Jul; 10(7):. PubMed ID: 28701488
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative Characterization of Biomechanical Behavior and Healing Profile of a Novel Ultra-High-Molecular-Weight Amorphous Poly-l-Lactic Acid Sirolimus-Eluting Bioresorbable Coronary Scaffold.
    Cheng Y; Gasior P; Shibuya M; Ramzipoor K; Lee C; Estrada EA; Dokko D; McGregor JC; Conditt GB; Kaluza GL; Granada JF
    Circ Cardiovasc Interv; 2016 Oct; 9(10):. PubMed ID: 27694138
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Randomized Trial Comparing the NeoVas Sirolimus-Eluting Bioresorbable Scaffold and Metallic Everolimus-Eluting Stents.
    Han Y; Xu B; Fu G; Wang X; Xu K; Jin C; Tao L; Li L; Hou Y; Su X; Fang Q; Chen L; Liu H; Wang B; Yuan Z; Gao C; Zhou S; Sun Z; Zhao Y; Guan C; Stone GW;
    JACC Cardiovasc Interv; 2018 Feb; 11(3):260-272. PubMed ID: 29413240
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Two-year longitudinal evaluation of a second-generation thin-strut sirolimus-eluting bioresorbable coronary scaffold with hybrid cell design in porcine coronary arteries.
    Gasior P; Cheng Y; Xia J; Conditt GB; McGregor JC; Virmani R; Granada JF; Kaluza GL
    Cardiol J; 2020; 27(2):115-125. PubMed ID: 30155861
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intracoronary optical coherence tomography and histology of overlapping everolimus-eluting bioresorbable vascular scaffolds in a porcine coronary artery model: the potential implications for clinical practice.
    Farooq V; Serruys PW; Heo JH; Gogas BD; Onuma Y; Perkins LE; Diletti R; Radu MD; Räber L; Bourantas CV; Zhang Y; van Remortel E; Pawar R; Rapoza RJ; Powers JC; van Beusekom HM; Garcìa-Garcìa HM; Virmani R
    JACC Cardiovasc Interv; 2013 May; 6(5):523-32. PubMed ID: 23702016
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Novel ultrahigh molecular weight amorphous PLLA bioresorbable coronary scaffold upsized up to 0.8 mm beyond nominal diameter: An OCT and histopathology study in porcine coronary artery model.
    Gasior P; Cheng Y; Estrada EA; Jenn McGregor ; Ramzipoor K; Lee C; Conditt GB; Rousselle SD; Granada JF; Kaluza GL
    Catheter Cardiovasc Interv; 2018 Feb; 91(3):378-386. PubMed ID: 28471065
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of strut thickness on acute mechanical performance: A comparison study using optical coherence tomography between DESolve 150 and DESolve 100.
    Boeder NF; Dörr O; Bauer T; Mattesini A; Elsässer A; Liebetrau C; Achenbach S; Hamm CW; Nef HM
    Int J Cardiol; 2017 Nov; 246():74-79. PubMed ID: 28579164
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparable vascular response of a new generation sirolimus eluting stents when compared to fluoropolymer everolimus eluting stents in the porcine coronary restenosis model.
    Buszman PP; Michalak MJ; Pruski M; Fernandez C; Jelonek M; Janas A; Savard C; Gwiazdowska-Nowotka B; Żurakowski A; Wojakowski W; Buszman PE; Milewski K
    Cardiol J; 2016; 23(6):657-666. PubMed ID: 27976797
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Incidence and imaging outcomes of acute scaffold disruption and late structural discontinuity after implantation of the absorb Everolimus-Eluting fully bioresorbable vascular scaffold: optical coherence tomography assessment in the ABSORB cohort B Trial (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions).
    Onuma Y; Serruys PW; Muramatsu T; Nakatani S; van Geuns RJ; de Bruyne B; Dudek D; Christiansen E; Smits PC; Chevalier B; McClean D; Koolen J; Windecker S; Whitbourn R; Meredith I; Garcia-Garcia HM; Veldhof S; Rapoza R; Ormiston JA
    JACC Cardiovasc Interv; 2014 Dec; 7(12):1400-11. PubMed ID: 25523532
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Post-dilatation after implantation of bioresorbable everolimus- and novolimus-eluting scaffolds: an observational optical coherence tomography study of acute mechanical effects.
    Blachutzik F; Boeder N; Wiebe J; Mattesini A; Dörr O; Most A; Bauer T; Röther J; Tröbs M; Schlundt C; Achenbach S; Hamm CW; Nef HM
    Clin Res Cardiol; 2017 Apr; 106(4):271-279. PubMed ID: 27757522
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Complex bifurcation lesions: Randomized comparison of a fully bioresorbable modified t stenting strategy versus bifurcation reconstruction with a dedicated self-expanding stent in combination with bioresorbable scaffolds, an OCT study: Rationale and design of the COBRA II trial.
    Bennett J; Adriaenssens T; Desmet W; Dubois C
    Catheter Cardiovasc Interv; 2016 Nov; 88(6):843-853. PubMed ID: 27184586
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Vascular response to bioresorbable polymer sirolimus-eluting stent vs. permanent polymer everolimus-eluting stent at 9-month follow-up: an optical coherence tomography sub-study from the CENTURY II trial.
    Kuramitsu S; Kazuno Y; Sonoda S; Domei T; Jinnouchi H; Yamaji K; Soga Y; Shirai S; Ando K; Saito S
    Eur Heart J Cardiovasc Imaging; 2016 Jan; 17(1):34-40. PubMed ID: 26333375
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of acute expansion of bioresorbable vascular scaffolds versus metallic drug-eluting stents in different degrees of calcification: An Optical Coherence Tomography Study.
    Ming Fam J; van Der Sijde JN; Karanasos A; Felix C; Diletti R; van Mieghem N; de Jaegere P; Zijlstra F; Jan van Geuns R; Regar E
    Catheter Cardiovasc Interv; 2017 Apr; 89(5):798-810. PubMed ID: 27717119
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Early vascular response of ultra-thin bioresorbable polymer sirolimus-eluting stents assessed by optical frequency domain imaging: the EVALUATION study.
    Miura T; Ueki Y; Senda K; Otagiri K; Tachibana T; Saigusa T; Ebisawa S; Motoki H; Ikeda U; Kuwahara K
    Cardiovasc Interv Ther; 2021 Jul; 36(3):281-288. PubMed ID: 32621170
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A next-generation bioresorbable coronary scaffold system: from bench to first clinical evaluation: 6- and 12-month clinical and multimodality imaging results.
    Verheye S; Ormiston JA; Stewart J; Webster M; Sanidas E; Costa R; Costa JR; Chamie D; Abizaid AS; Pinto I; Morrison L; Toyloy S; Bhat V; Yan J; Abizaid A
    JACC Cardiovasc Interv; 2014 Jan; 7(1):89-99. PubMed ID: 24139932
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Head-to-head comparison of the neointimal response between metallic and bioresorbable everolimus-eluting scaffolds using optical coherence tomography.
    Gomez-Lara J; Brugaletta S; Farooq V; Onuma Y; Diletti R; Windecker S; Thuesen L; McClean D; Koolen J; Whitbourn R; Dudek D; Smits PC; Chevalier B; Regar E; Veldhof S; Rapoza R; Ormiston JA; Garcia-Garcia HM; Serruys PW
    JACC Cardiovasc Interv; 2011 Dec; 4(12):1271-80. PubMed ID: 22192368
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Randomized Comparison of Absorb Bioresorbable Vascular Scaffold and Mirage Microfiber Sirolimus-Eluting Scaffold Using Multimodality Imaging.
    Tenekecioglu E; Serruys PW; Onuma Y; Costa R; Chamié D; Sotomi Y; Yu TB; Abizaid A; Liew HB; Santoso T
    JACC Cardiovasc Interv; 2017 Jun; 10(11):1115-1130. PubMed ID: 28527768
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of the second generation of a bioresorbable everolimus drug-eluting vascular scaffold for treatment of de novo coronary artery stenosis: six-month clinical and imaging outcomes.
    Serruys PW; Onuma Y; Ormiston JA; de Bruyne B; Regar E; Dudek D; Thuesen L; Smits PC; Chevalier B; McClean D; Koolen J; Windecker S; Whitbourn R; Meredith I; Dorange C; Veldhof S; Miquel-Hebert K; Rapoza R; García-García HM
    Circulation; 2010 Nov; 122(22):2301-12. PubMed ID: 21098436
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optical coherence tomography tissue coverage and characterization at six months after implantation of bioresorbable scaffolds versus conventional everolimus eluting stents in the ISAR-Absorb MI trial.
    Rai H; Alfonso F; Maeng M; Bradaric C; Wiebe J; Cuesta J; Christiansen EH; Cassese S; Hoppmann P; Colleran R; Harzer F; Bresha J; Nano N; Schneider S; Laugwitz KL; Joner M; Kastrati A; Byrne RA
    Int J Cardiovasc Imaging; 2021 Oct; 37(10):2815-2826. PubMed ID: 34420177
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.