33 related articles for article (PubMed ID: 30968934)
1. The Anastomotic Angle of Hemodialysis Arteriovenous Fistula Is Associated With Flow Disturbance at the Venous Stenosis Location on Angiography.
Yang CY; Li MC; Lan CW; Lee WJ; Lee CJ; Wu CH; Tang JM; Niu YY; Lin YP; Shiu YT; Cheung AK; Lee YW; Lee OK; Chien S; Tarng DC
Front Bioeng Biotechnol; 2020; 8():846. PubMed ID: 32793578
[TBL] [Abstract][Full Text] [Related]
2. Effect of blood viscosity on the hemodynamics of arteriovenous fistulae based on numerical investigation.
Zhao N; Zhang T; Zhang T; Wang B; Mu W; Wang F
Comput Methods Biomech Biomed Engin; 2024 Apr; ():1-13. PubMed ID: 38563312
[TBL] [Abstract][Full Text] [Related]
3. Stenosis to stented: decrease in flow disturbances following stent implantation of a diseased arteriovenous fistula.
Gunasekera S; de Silva C; Ng O; Thomas S; Varcoe R; Barber T
Biomech Model Mechanobiol; 2024 Apr; 23(2):453-468. PubMed ID: 38063956
[TBL] [Abstract][Full Text] [Related]
4. Are Non-Newtonian Effects Important in Hemodynamic Simulations of Patients With Autogenous Fistula?
Javid Mahmoudzadeh Akherat SM; Cassel K; Boghosian M; Dhar P; Hammes M
J Biomech Eng; 2017 Apr; 139(4):0445041-9. PubMed ID: 28249082
[TBL] [Abstract][Full Text] [Related]
5. Turbulent blood dynamics in the left heart in the presence of mitral regurgitation: a computational study based on multi-series cine-MRI.
Bennati L; Giambruno V; Renzi F; Di Nicola V; Maffeis C; Puppini G; Luciani GB; Vergara C
Biomech Model Mechanobiol; 2023 Dec; 22(6):1829-1846. PubMed ID: 37400622
[TBL] [Abstract][Full Text] [Related]
6. An Image-Based Computational Fluid Dynamics Study of Mitral Regurgitation in Presence of Prolapse.
Bennati L; Vergara C; Giambruno V; Fumagalli I; Corno AF; Quarteroni A; Puppini G; Luciani GB
Cardiovasc Eng Technol; 2023 Jun; 14(3):457-475. PubMed ID: 37069336
[TBL] [Abstract][Full Text] [Related]
7. Association of Shear Stress with Subsequent Lumen Remodeling in Hemodialysis Arteriovenous Fistulas.
He Y; Shiu YT; Imrey PB; Radeva MK; Beck GJ; Gassman JJ; Northrup HM; Roy-Chaudhury P; Berceli SA; Cheung AK;
Clin J Am Soc Nephrol; 2023 Jan; 18(1):72-83. PubMed ID: 36446600
[TBL] [Abstract][Full Text] [Related]
8. Medical Image-Based Computational Fluid Dynamics and Fluid-Structure Interaction Analysis in Vascular Diseases.
He Y; Northrup H; Le H; Cheung AK; Berceli SA; Shiu YT
Front Bioeng Biotechnol; 2022; 10():855791. PubMed ID: 35573253
[TBL] [Abstract][Full Text] [Related]
9. Disturbed flow's impact on cellular changes indicative of vascular aneurysm initiation, expansion, and rupture: A pathological and methodological review.
Sunderland K; Jiang J; Zhao F
J Cell Physiol; 2022 Jan; 237(1):278-300. PubMed ID: 34486114
[TBL] [Abstract][Full Text] [Related]
10. The geometry of arteriovenous fistulas using endothelial nitric oxide synthase mouse models.
Falzon I; Northrup H; Guo L; Totenhagen J; Lee T; Shiu YT
Kidney360; 2020 Sep; 1(9):925-935. PubMed ID: 33117991
[TBL] [Abstract][Full Text] [Related]
11. Analyses of hemodialysis arteriovenous fistula geometric configuration and its associations with maturation and reintervention.
He Y; Northrup H; Roy-Chaudhury P; Cheung AK; Berceli SA; Shiu YT
J Vasc Surg; 2021 May; 73(5):1778-1786.e1. PubMed ID: 33091518
[TBL] [Abstract][Full Text] [Related]
12. Effect of anastomosis angle on the localization of disturbed flow in 'side-to-end' fistulae for haemodialysis access.
Ene-Iordache B; Cattaneo L; Dubini G; Remuzzi A
Nephrol Dial Transplant; 2013 Apr; 28(4):997-1005. PubMed ID: 22785110
[TBL] [Abstract][Full Text] [Related]
13. Assessing radiocephalic wrist arteriovenous fistulas of obtuse anastomosis using computational fluid dynamics and clinical application.
Lee J; Kim S; Kim SM; Song R; Kim HK; Park JS; Park SC
J Vasc Access; 2016 Nov; 17(6):512-520. PubMed ID: 27791257
[TBL] [Abstract][Full Text] [Related]
14. A Review of the Hemodynamic Factors Believed to Contribute to Vascular Access Dysfunction.
Cunnane CV; Cunnane EM; Walsh MT
Cardiovasc Eng Technol; 2017 Sep; 8(3):280-294. PubMed ID: 28527110
[TBL] [Abstract][Full Text] [Related]
15. Blood Flow in Idealized Vascular Access for Hemodialysis: A Review of Computational Studies.
Ene-Iordache B; Remuzzi A
Cardiovasc Eng Technol; 2017 Sep; 8(3):295-312. PubMed ID: 28664239
[TBL] [Abstract][Full Text] [Related]
16. Assessing the Disturbed Flow and the Transition to Turbulence in the Arteriovenous Fistula.
Stella S; Vergara C; Giovannacci L; Quarteroni A; Prouse G
J Biomech Eng; 2019 Oct; 141(10):. PubMed ID: 30968934
[TBL] [Abstract][Full Text] [Related]
17. Prediction of the anastomosis angle of arteriovenous fistula in hemodialysis to standardize the surgical technique.
Shembekar SN; Zodpe DB; Padole PM
Biomed Mater Eng; 2022; 33(5):423-436. PubMed ID: 35253728
[TBL] [Abstract][Full Text] [Related]
18.
; ; . PubMed ID:
[No Abstract] [Full Text] [Related]
19.
; ; . PubMed ID:
[No Abstract] [Full Text] [Related]
20.
; ; . PubMed ID:
[No Abstract] [Full Text] [Related]