205 related articles for article (PubMed ID: 30972922)
1. Clinical implementation of respiratory-gated spot-scanning proton therapy: An efficiency analysis of active motion management.
Gelover E; Deisher AJ; Herman MG; Johnson JE; Kruse JJ; Tryggestad EJ
J Appl Clin Med Phys; 2019 May; 20(5):99-108. PubMed ID: 30972922
[TBL] [Abstract][Full Text] [Related]
2. Comprehensive beam delivery latency evaluation for gated proton therapy system using customized multi-channel signal acquisition platform.
Liu Z; Pan L; Ma T; Lu HM; Wang Y
J Appl Clin Med Phys; 2024 May; 25(5):e14349. PubMed ID: 38551392
[TBL] [Abstract][Full Text] [Related]
3. Motion management within two respiratory-gating windows: feasibility study of dual quasi-breath-hold technique in gated medical procedures.
Kim T; Kim S; Park YK; Youn KK; Keall P; Lee R
Phys Med Biol; 2014 Nov; 59(21):6583-94. PubMed ID: 25321091
[TBL] [Abstract][Full Text] [Related]
4. Amplitude gating for a coached breathing approach in respiratory gated 10 MV flattening filter-free VMAT delivery.
Viel F; Lee R; Gete E; Duzenli C
J Appl Clin Med Phys; 2015 Jul; 16(4):78–90. PubMed ID: 26219000
[TBL] [Abstract][Full Text] [Related]
5. Effectiveness of respiratory-gated radiotherapy with audio-visual biofeedback for synchrotron-based scanned heavy-ion beam delivery.
He P; Li Q; Zhao T; Liu X; Dai Z; Ma Y
Phys Med Biol; 2016 Dec; 61(24):8541-8552. PubMed ID: 27845937
[TBL] [Abstract][Full Text] [Related]
6. Characteristics of gated treatment using an optical surface imaging and gating system on an Elekta linac.
Freislederer P; Reiner M; Hoischen W; Quanz A; Heinz C; Walter F; Belka C; Soehn M
Radiat Oncol; 2015 Mar; 10():68. PubMed ID: 25881018
[TBL] [Abstract][Full Text] [Related]
7. Commissioning of the 4-D treatment delivery system for organ motion management in synchrotron-based scanning ion beams.
Ciocca M; Mirandola A; Molinelli S; Russo S; Mastella E; Vai A; Mairani A; Magro G; Pella A; Donetti M; Valvo F; Fossati P; Baroni G
Phys Med; 2016 Dec; 32(12):1667-1671. PubMed ID: 27890567
[TBL] [Abstract][Full Text] [Related]
8. Low-cost Kinect Version 2 imaging system for breath hold monitoring and gating: Proof of concept study for breast cancer VMAT radiotherapy.
Edmunds DM; Gothard L; Khabra K; Kirby A; Madhale P; McNair H; Roberts D; Tang KK; Symonds-Tayler R; Tahavori F; Wells K; Donovan E
J Appl Clin Med Phys; 2018 May; 19(3):71-78. PubMed ID: 29536664
[TBL] [Abstract][Full Text] [Related]
9. Optimization of motion management parameters in a synchrotron-based spot scanning system.
Johnson JE; Herman MG; Kruse JJ
J Appl Clin Med Phys; 2019 Sep; 20(9):69-77. PubMed ID: 31538720
[TBL] [Abstract][Full Text] [Related]
10. Does gated beam delivery impact delivery accuracy on an Elekta linac?
Jermoumi M; Xie R; Cao D; Housley DJ; Shepard DM
J Appl Clin Med Phys; 2017 Jan; 18(1):90-95. PubMed ID: 28291908
[TBL] [Abstract][Full Text] [Related]
11. Development and long-term stability of a comprehensive daily QA program for a modern pencil beam scanning (PBS) proton therapy delivery system.
Rana S; Bennouna J; Samuel EJJ; Gutierrez AN
J Appl Clin Med Phys; 2019 Apr; 20(4):29-44. PubMed ID: 30920146
[TBL] [Abstract][Full Text] [Related]
12. Analysis of treatment process time for real-time-image gated-spot-scanning proton-beam therapy (RGPT) system.
Yoshimura T; Shimizu S; Hashimoto T; Nishioka K; Katoh N; Inoue T; Taguchi H; Yasuda K; Matsuura T; Takao S; Tamura M; Ito YM; Matsuo Y; Tamura H; Horita K; Umegaki K; Shirato H
J Appl Clin Med Phys; 2020 Feb; 21(2):38-49. PubMed ID: 31886616
[TBL] [Abstract][Full Text] [Related]
13. Comparing phase- and amplitude-gated volumetric modulated arc therapy for stereotactic body radiation therapy using 3D printed lung phantom.
Lee M; Yoon K; Cho B; Kim SS; Song SY; Choi EK; Ahn S; Lee SW; Kwak J
J Appl Clin Med Phys; 2019 Feb; 20(2):107-113. PubMed ID: 30667581
[TBL] [Abstract][Full Text] [Related]
14. The M. D. Anderson proton therapy system.
Smith A; Gillin M; Bues M; Zhu XR; Suzuki K; Mohan R; Woo S; Lee A; Komaki R; Cox J; Hiramoto K; Akiyama H; Ishida T; Sasaki T; Matsuda K
Med Phys; 2009 Sep; 36(9):4068-83. PubMed ID: 19810479
[TBL] [Abstract][Full Text] [Related]
15. Optimizing mini-ridge filter thickness to reduce proton treatment times in a spot-scanning synchrotron system.
Courneyea L; Beltran C; Tseung HS; Yu J; Herman MG
Med Phys; 2014 Jun; 41(6):061713. PubMed ID: 24877808
[TBL] [Abstract][Full Text] [Related]
16. Integration of a real-time tumor monitoring system into gated proton spot-scanning beam therapy: an initial phantom study using patient tumor trajectory data.
Matsuura T; Miyamoto N; Shimizu S; Fujii Y; Umezawa M; Takao S; Nihongi H; Toramatsu C; Sutherland K; Suzuki R; Ishikawa M; Kinoshita R; Maeda K; Umegaki K; Shirato H
Med Phys; 2013 Jul; 40(7):071729. PubMed ID: 23822433
[TBL] [Abstract][Full Text] [Related]
17. A quality assurance for respiratory gated proton irradiation with range modulation wheel.
Yasui K; Shimomura A; Toshito T; Tanaka K; Ueki K; Muramatsu R; Katsurada M; Hayashi N; Ogino H
J Appl Clin Med Phys; 2019 Jan; 20(1):258-264. PubMed ID: 30597762
[TBL] [Abstract][Full Text] [Related]
18. Comparison of two methods for minimizing the effect of delayed charge on the dose delivered with a synchrotron based discrete spot scanning proton beam.
Whitaker TJ; Beltran C; Tryggestad E; Bues M; Kruse JJ; Remmes NB; Tasson A; Herman MG
Med Phys; 2014 Aug; 41(8):081703. PubMed ID: 25086513
[TBL] [Abstract][Full Text] [Related]
19. Dosimetric evaluation of the interplay effect in respiratory-gated RapidArc radiation therapy.
Riley C; Yang Y; Li T; Zhang Y; Heron DE; Huq MS
Med Phys; 2014 Jan; 41(1):011715. PubMed ID: 24387507
[TBL] [Abstract][Full Text] [Related]
20. Dosimetric evaluations of the interplay effect in respiratory-gated intensity-modulated radiation therapy.
Chen H; Wu A; Brandner ED; Heron DE; Huq MS; Yue NJ; Chen WC
Med Phys; 2009 Mar; 36(3):893-903. PubMed ID: 19378749
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]