118 related articles for article (PubMed ID: 30973284)

  • 1. Air contamination during medical treatment results in deposits of microemboli in the lungs: An autopsy study.
    Forsberg U; Jonsson P; Stegmayr B
    Int J Artif Organs; 2019 Sep; 42(9):477-481. PubMed ID: 30973284
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Microbubbles of air may occur in the organs of hemodialysis patients.
    Stegmayr B; Brännström T; Forsberg U; Jonson P; Stegmayr C; Hultdin J
    ASAIO J; 2012; 58(2):177-9. PubMed ID: 22236622
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Microemboli induced by air bubbles may be deposited in organs as a consequence of contamination during medical care.
    Forsberg U; Jonsson P; Stegmayr B
    Clin Kidney J; 2023 Jan; 16(1):159-166. PubMed ID: 36726427
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hemodialysis dialyzers contribute to contamination of air microemboli that bypass the alarm system in the air trap.
    Stegmayr C; Jonsson P; Forsberg U; Stegmayr B
    Int J Artif Organs; 2008 Apr; 31(4):317-22. PubMed ID: 18432587
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effectiveness of microbubble removal in an airtrap with a free surface interface.
    Keshavarzi G; Simmons A; Yeoh G; Barber T
    J Biomech; 2015 May; 48(7):1237-40. PubMed ID: 25841295
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A high blood level in the air trap reduces microemboli during hemodialysis.
    Forsberg U; Jonsson P; Stegmayr C; Stegmayr B
    Artif Organs; 2012 Jun; 36(6):525-9. PubMed ID: 22360799
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Microemboli, developed during haemodialysis, pass the lung barrier and may cause ischaemic lesions in organs such as the brain.
    Forsberg U; Jonsson P; Stegmayr C; Stegmayr B
    Nephrol Dial Transplant; 2010 Aug; 25(8):2691-5. PubMed ID: 20305135
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Air contamination during hemodialysis should be minimized.
    Stegmayr B
    Hemodial Int; 2017 Apr; 21(2):168-172. PubMed ID: 27576675
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pathophysiology and clinical implications of microbubbles during hemodialysis.
    Barak M; Nakhoul F; Katz Y
    Semin Dial; 2008; 21(3):232-8. PubMed ID: 18363602
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sources of Mortality on Dialysis with an Emphasis on Microemboli.
    Stegmayr BG
    Semin Dial; 2016 Nov; 29(6):442-446. PubMed ID: 27528100
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A high blood level in the venous chamber and a wet-stored dialyzer help to reduce exposure for microemboli during hemodialysis.
    Forsberg U; Jonsson P; Stegmayr C; Jonsson F; Nilsson B; Nilsson Ekdahl K; Stegmayr B
    Hemodial Int; 2013 Oct; 17(4):612-7. PubMed ID: 23627921
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The sensor in the venous chamber does not prevent passage of air bubbles during hemodialysis.
    Stegmayr B; Forsberg U; Jonsson P; Stegmayr C
    Artif Organs; 2007 Feb; 31(2):162-6. PubMed ID: 17298408
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Acoustical bubble trapper applied to hemodialysis.
    Palanchon P; Birmelé B; Tranquart F
    Ultrasound Med Biol; 2008 Apr; 34(4):681-4. PubMed ID: 17996355
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Two-dimensional computational analysis of microbubbles in hemodialysis.
    Keshavarzi G; Barber TJ; Yeoh G; Simmons A; Reizes JA
    Artif Organs; 2013 Aug; 37(8):E139-44. PubMed ID: 23826686
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Air bubbles pass the security system of the dialysis device without alarming.
    Jonsson P; Karlsson L; Forsberg U; Gref M; Stegmayr C; Stegmayr B
    Artif Organs; 2007 Feb; 31(2):132-9. PubMed ID: 17298402
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Novel Capped-Needle Device: A Novel Safety Feature to Eliminate Air Bubbles in Hemodialysis.
    Shibata K; Shinzato T; Toma S; Nakai S; Kobayashi Y; Hashimoto T; Tamura K
    Blood Purif; 2023; 52(1):54-59. PubMed ID: 35468597
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hemodialysis machine air detectors need not detect microbubbles.
    Polaschegg HD
    Artif Organs; 2007 Dec; 31(12):911-2; author reply 913-4. PubMed ID: 18039272
    [No Abstract]   [Full Text] [Related]  

  • 18. Pathochemical toxicity of perfluorocarbon-5070, a liquid test performance fluid previously used in dialyzer manufacturing, confirmed in animal experiment.
    Canaud B; Aljama P; Tielemans C; Gasparovic V; Gutierrez A; Locatelli F
    J Am Soc Nephrol; 2005 Jun; 16(6):1819-23. PubMed ID: 15829702
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Patent foramen ovale, dialysis and microembolization.
    George S; Holt S; Hildick-Smith D
    Nephrology (Carlton); 2012 Aug; 17(6):569-74. PubMed ID: 22487266
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Genesis and diagnostic value of leukocyte and platelet accumulations around "air bubbles" in blood after venous air embolism.
    Ritz-Timme S; Eckelt N; Schmidtke E; Thomsen H
    Int J Legal Med; 1998; 111(1):22-6. PubMed ID: 9457534
    [TBL] [Abstract][Full Text] [Related]  