BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 30977523)

  • 1. Carrier ampholyte-free free-flow isoelectric focusing for separation of protein.
    Wang S; Zhang L; Sun H; Chu Z; Chen H; Zhao Y; Zhang W
    Electrophoresis; 2019 Sep; 40(18-19):2610-2617. PubMed ID: 30977523
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of a novel ampholyte buffer for isoelectric focusing: electric charge-separation of protein samples for X-ray crystallography using free-flow isoelectric focusing.
    Kim SH; Miyatake H; Ueno T; Nagao T; Miki K
    Acta Crystallogr D Biol Crystallogr; 2005 Jun; 61(Pt 6):799-802. PubMed ID: 15930643
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Steady-state protein focusing in carrier ampholyte-based isoelectric focusing: Part II-validation and case studies.
    Shim J; Yoo K; Dutta P
    Electrophoresis; 2017 Mar; 38(5):667-676. PubMed ID: 27868220
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surface isoelectric focusing (sIEF) with carrier ampholyte pH gradient.
    Wang Z; Ivory C; Minerick AR
    Electrophoresis; 2017 Oct; 38(20):2565-2575. PubMed ID: 28722147
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of the operational pH value of a buffering membrane by an isoelectric trapping separation of a carrier ampholyte mixture.
    North RY; Vigh G
    Electrophoresis; 2008 Mar; 29(5):1077-81. PubMed ID: 18271066
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid and effective focusing in a carrier ampholyte solution isoelectric focusing system: a proteome prefractionation tool.
    Tran JC; Doucette AA
    J Proteome Res; 2008 Apr; 7(4):1761-6. PubMed ID: 18284188
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sampling strategies for capillary isoelectric focusing with electroosmotic zone mobilization assessed by high-resolution dynamic computer simulation.
    Takácsi-Nagy A; Kilár F; Páger C; Mosher RA; Thormann W
    Electrophoresis; 2012 Mar; 33(6):970-80. PubMed ID: 22655305
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Carrier ampholyte-free isoelectric focusing on a paper-based analytical device for the fractionation of proteins.
    Xie SF; Gao H; Niu LL; Xie ZS; Fang F; Wu ZY; Yang FQ
    J Sep Sci; 2018 May; 41(9):2085-2091. PubMed ID: 29370473
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a simple ampholyte-free isoelectric focusing slab electrophoresis for protein fractionation.
    Zhan Y; Lemma T; Musteata MF; Pawliszyn J
    J Chromatogr A; 2009 Apr; 1216(14):2928-33. PubMed ID: 18752802
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Modeling of formation and prevention of a pure water zone in capillary isoelectric focusing with narrow pH range carrier ampholytes.
    Takácsi-Nagy A; Kilár F; Thormann W
    Electrophoresis; 2017 Mar; 38(5):677-688. PubMed ID: 27699824
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fast preparation of monolithic immobilized pH gradient column by photopolymerization and photografting techniques for isoelectric focusing separation of proteins.
    Liang Y; Zhu G; Wang T; Zhang X; Liang Z; Zhang L; Zhang Y
    Electrophoresis; 2011 Oct; 32(20):2911-4. PubMed ID: 21948237
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of electrolyte pH on CIEF with narrow pH range ampholytes.
    Páger C; Vargová A; Takácsi-Nagy A; Dörnyei Á; Kilár F
    Electrophoresis; 2012 Nov; 33(22):3269-75. PubMed ID: 23086725
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Steady-state protein focusing in carrier ampholyte based isoelectric focusing: Part I-Analytical solution.
    Shim J; Yoo K; Dutta P
    Electrophoresis; 2017 Mar; 38(5):659-666. PubMed ID: 27874208
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sequential injection setup for capillary isoelectric focusing combined with MS detection.
    Páger C; Dörnyei A; Kilár F
    Electrophoresis; 2011 Jul; 32(14):1875-84. PubMed ID: 21769892
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Carrier ampholytes rehabilitated: gel isoelectric focusing on pH gradients visualized in real-time by automated fluorescence scanning in the HPGE-1000 apparatus.
    Gombocz E; Cortez E
    Electrophoresis; 1999 Jun; 20(7):1365-72. PubMed ID: 10424457
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Conductivity properties of carrier ampholyte pH gradients in isoelectric focusing.
    Stoyanov AV; Das C; Fredrickson CK; Fan ZH
    Electrophoresis; 2005 Jan; 26(2):473-9. PubMed ID: 15657903
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of different mobilization strategies for capillary isoelectric focusing of ovalbumin variants.
    Kristl T; Stutz H
    J Sep Sci; 2015 Jan; 38(1):148-56. PubMed ID: 25358859
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Separation and fractionation of glutamic acid and histidine via origami isoelectric focusing.
    Danchana K; Yamashita N; Umeda MI; Kaneta T
    J Chromatogr A; 2023 Sep; 1706():464247. PubMed ID: 37531850
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Two-dimensional electrophoresis of basic proteins with equilibrium isoelectric focusing in carrier ampholyte-pH gradients.
    Rabilloud T
    Electrophoresis; 1994 Feb; 15(2):278-82. PubMed ID: 8026444
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Advanced online mass spectrometry detection of proteins separated by capillary isoelectric focusing after sequential injection.
    Páger C; Biherczová N; Ligetvári R; Berkics BV; Pongrácz T; Sándor V; Bufa A; Poór V; Vojs Staňová A; Kilár F
    J Sep Sci; 2017 Dec; 40(24):4825-4834. PubMed ID: 29064636
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.